Table 7-7. Other Errors Appearing on the BIOS
Issue
The RAID 0 goes
offline and the RAID 1
becomes degraded in a
PowerEdge R210
system with two drives.
When attempting to
update system
backplane firmware
and or Hard drive
firmware using DUPs
the updates fail.
eSata devices appear in
Ready state in CTLR-R
During CTRL-R,
S100/S300 do not
display greater than
eight Virtual Disks.
Unable to delete
Virtual Disks when
there are more than
eight Virtual Disks
present in the system.
Virtual disk rebuild
status while during
CTLR-R
Likely Causes to Check Corrective Actions
Faulty physical disk
DUPs are not
supported.
Issue with the physical
connection
The function is not
supported.
The function is not
supported.
Rebuild is not
supported in Ctrl-R.
Boot system into CTLR-R and
1
replace faulty drive.
Delete the failed RAID 0 and then
2
create a new RAID 0. Now RAID 0
is optimal and RAID 1 is still
degraded.
Install OS on the RAID 0 and
3
backup RAID 1.
Delete and Recreate RAID 1 and
4
restore backup data.
Use the DOS utilities
Remove the devices from eSata port
and plug them into the chassis.
NOTE:
eSATA devices are blocked
from virtual disk creation.
Remove all physical disks except for
the last one(s) added. Then proceed
with deleting the virtual disks that
are not needed. Remember to take
account of the virtual disks that are
currently being used.
Remove all physical disks except for
the last one(s) added. Then proceed
with deleting the virtual disks that
are not needed. Remember to take
account of the virtual disks that are
currently being used.
Boot to a supported OS. Rebuild
starts. To view rebuild status, install
a supported storage application.
Troubleshooting