If the product is shipped to the location of the UNI-T service center, UNI-T shall pay the return shipping fee. If the product is sent to any other location, the customer shall be responsible for all shipping, duties, taxes, and any other expenses.
MSO7000X Series Mixed Signal Oscilloscope or integration increases time or difficulty of repair). The warranty is formulated by UNI-T for this product, replacing any other express or implied warranties. UNI-T and its distributors refuse to give any implied warranty for marketability or applicability for special purpose.
Please follow the following guidelines to avoid possible electric shock and risk to personal safety. Users must follow the following conventional safety precautions in operation, service and maintenance of this device. UNI-T will not be liable for any personal safety and property loss caused by the user’s failure to Warning follow the following safety precautions.
Page 6
MSO7000X Series Mixed Signal Oscilloscope “Note” indicates important information. It reminds users to pay attention to procedures, methods and conditions, etc. The contents of the “Note” Note should be highlighted if necessary. Safety Sign It indicates possible danger of electric shock, which may Danger cause personal injury or death.
Page 7
MSO7000X Series Mixed Signal Oscilloscope Secondary electrical circuit connected to wall sockets through transformers or similar equipment, such as electronic instruments and electronic CAT I equipment; electronic equipment with protective measures, and any high- voltage and low-voltage circuits, such as the copier in the office.
Page 8
MSO7000X Series Mixed Signal Oscilloscope Safety Requirement Warning Please connect this device to AC power supply with the power cable provided. Preparation The AC input voltage of the line reaches the rated value of this device. See before use the product manual for specific rated value.
Page 9
If this device may be faulty, please contact the authorized maintenance Abnormality personnel of UNI-T for testing. Any maintenance, adjustment or parts replacement must be done by the relevant personnel of UNI-T. Do not block the ventilation holes at the side and back of this device;...
Page 10
MSO7000X Series Mixed Signal Oscilloscope Poor ventilation will cause the device temperature to rise, thus causing Proper ventilation damage to this device. Please keep proper ventilation during use, and regularly check the vents and fans. Keep clean and Please take actions to avoid dust or moisture in the air affecting the performance of this device.
Page 11
MSO7000X Series Mixed Signal Oscilloscope MSO7000X Series Mixed Signal Oscilloscope MSO7000X series is the brand new mixed signal oscilloscope launched by UNI-T. The bandwidth up to 2GHz and sampling rate up to 10GSa/s, which has obvious advantages in high-speed signal analysis.MSO7000X has unique UltraAcq®...
MSO7000X Series Mixed Signal Oscilloscope Quick Guide This chapter is to introduce on using the MSO7000X series oscilloscope for the first time, the front and rear panels, the user interface, as well as WebServer. General Inspection It is recommended to inspect the instrument follow the steps below before using the MSO7000X series oscilloscope for the first time.
MSO7000X Series Mixed Signal Oscilloscope Before Use To perform a quick verification of the instrument’s normal operations, please follow the steps below. 1. Connecting to the Power Supply The power supply voltage range is from 100 VAC to 240 VAC, the frequency range is 50 Hz to 60 Hz.
Page 14
MSO7000X Series Mixed Signal Oscilloscope 5. Probe Compensation When the probe is connected to any input channel for the first time, this step might be adjusted to match the probe and the input channel. Probes that are not compensated may lead to measurement errors or mistake.
MSO7000X Series Mixed Signal Oscilloscope Front Panel Figure 3 Front Panel Table 1 Function key on Front Panel Description Description Display area Vertical control knob Run/Stop key, Autoset key Analog channel key Analog channel input port and Trigger control area (Trigger)
Page 17
MSO7000X Series Mixed Signal Oscilloscope Rear Panel Figure 4 Rear Panel Table 2 Interface on Rear Panel Description Description USB Host port AUX In port HDMI port AUX Out port LAN port Ground terminal USB Device port Power input and switch...
MSO7000X Series Mixed Signal Oscilloscope communication. 10MHz Ref In: provide the reference clock of sampling for the oscilloscope 10MHz Ref Out: BNC connector on the rear panel, it can output its own 10MHz reference clock and provide it to other external instruments for inter-instrument clock synchronization.
Page 19
MSO7000X Series Mixed Signal Oscilloscope Single trigger Window display and setting Autoset Trigger level cursor Horizontal scale and delay Frequency counter Acquisition mode, storage Digital voltmeter depth and sampling rate Function/Arbitrary waveform Trigger information 24/25 generator Cursor measurement Protocol analyzer Logic analyzer UltraAcq®...
Squeeze ◼ Drag MSO7000X series provides 15.6 inch super capacitive touch screen, multiple point touch control and gesture control. MSO7000X has easily operating system with flexible and high sensitive touch screen features for great waveform display and excellent user experience.
Page 21
MSO7000X Series Mixed Signal Oscilloscope Squeeze Squeeze two fingers together or separate. Squeeze gesture can zoom out or zoom in the waveform. If the waveform need to zoom out, squeeze two finger together and then slide away; If the waveform need to zoom out, separate two fingers and then squeeze two fingers together as shown in Figure 7.
Page 22
MSO7000X Series Mixed Signal Oscilloscope Icon of Start Menu Start menu: tap the icon on the right top corner to turn on the start menu, as shown in Figure 9. Figure 9 Start Menu Cursor measurement: turn on the cursor measurement function...
MSO7000X Series Mixed Signal Oscilloscope Measurement Menu Measurement menu: tap the icon on the left corner to turn on the measurement menu, as shown in Figure 10. Figure 10 Measurement Menu Digital Voltmeter: turn on the digital voltmeter measurement, it supports 4-digital...
Page 24
MSO7000X Series Mixed Signal Oscilloscope Communication MSO7000X series supports communication with computer through USB and LAN port, so as to realize remote control. The remote control is based on SCPI (Standard Commands for Programmable Instruments). MSO7000X series supports three communication modes...
MSO7000X Series Mixed Signal Oscilloscope USB can display manufacture’s ID, product ID, serial number and current VISA address (as shown in Figure 12). The oscilloscope can communicate with the host computer directly through the USB Device port on the rear panel and configuration parameters is not required.
Page 26
MSO7000X Series Mixed Signal Oscilloscope Figure 13 Home page of Web Server Figure 14 Remote Control www.uni-trend.com...
Page 27
MSO7000X Series Mixed Signal Oscilloscope Access from Cellphone It is required that the cellphone and the oscilloscope are under the same LAN (generally under the same WLAN band), and access the oscilloscope local IP through the oscilloscope setup menu, and then the browser accesses the IP: 80 port (as shown in Figure 15, Figure 16).
This section describes a list of faults and troubleshooting methods that may occur during the use of the oscilloscope. When you encounter these faults, please follow the corresponding steps to deal with them, if the problem cannot be fixed, please contact UNI-T, and provide the equipment information of your machine.
③ Check whether the screen and your fingers with oil. If there is, clean your fingers and the screen. ④ If the product still does not work properly, contact the UNI-T Service Center for assistance. (6) Waveform refresh is very slow.
If the product is proven to be defective within this period, UNI-T will repair or replace the product in accordance with the detailed provisions of the warranty.
Page 31
Service support: 8am to 5.30pm (UTC+8), Monday to Friday or via email. Our email address is infosh@uni-trend.com.cn For product support outside mainland China, please contact your local UNI-T distributor or sales center. Many UNI-T products have the option of extending the warranty and calibration period, please contact your local UNI-T dealer or sales center.
Need help?
Do you have a question about the MSO7000X Series and is the answer not in the manual?
Questions and answers