Product Specifications – DD96TC
Heating Data
High Fire Input¹
High Fire Output¹
Low-Fire Input¹
Low-Fire Output¹
AFUE²
Temperature Rise Range (°F) High/Low Fire
Vent Diameter³
No. of Burners
Circulator Blower
Available AC @ 0.5" ESP
Size (D x W)
Horsepower @ 1075 RPM
No. of Speeds
FILTER SIZE (IN²) (QTY)
Electrical Data
Min. Circuit Ampacity ³
Max. Overcurrent Device (amps) ⁴
Shipping Weight (lbs)
¹ Natural Gas BTU/h; for altitudes 0-4500' above sea level, reduce input rating by 4% for each 1000' above 4500' altitude.
² DOE AFUE based upon Isolated Combustion System (ICS)
³ Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI
Z223.1 (in the USA) and the Canada
⁴ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National
Electrical Codes. Extensive wire runs will require larger wire sizes.
⁵ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers
of the same size as noted.
Notes
• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
• Gas Service Connection ½" FPT
• Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing
local codes.
• For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.
• For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum
clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
4
DD96TC
DD96TC
DD96TC
0403BN
0603BN
0804CN
40,000
60,000
80,000
38,440
57,660
76,880
28,000
42,000
56,000
26,908
40,362
53,816
96.1
96.1
35-65 / 25-55
20-50 / 20-50
35-65 / 35-65
2" - 3"
2" - 3"
2
3
1.5 - 3
1.5 - 3
10" x 8"
11" x 8"
11" x 10"
1/2
1/2
VS ECM
VS ECM
VS ECM
(2) 10 x 20 or
(2) 10 x 20 or
(2) 10 x 20 or
(1) 16 x 25
(1) 16 x 25
(1) 16 x 25
(top return)
(top return)
(top return)
7.6
7.6
15
15
116
119
www.daikincomfort.com
DD96TC
1005CN
100,000
96,100
70,000
67,270
96.1
96.1
35-65 / 35-65
2" - 3"
2" - 3"
4
5
1.5 - 4
2 - 5
11" x 10"
3/4
1
VS ECM
(1) 14 x 20 (bottom)
(1) 14 x 20 (bottom)
or (1) 20 x 25
(top return)
10.9
13.9
15
20
143
145
DD96TC
1205DN
120,000
115,320
84,000
80,724
96.1
35-65 / 35-65
2" - 3"
6
2 - 5
11" x 11"
1
VS ECM
or (1) 20 x 25
(top return)
13.9
20
158
SS-DR96TC_DD96TC-R32