Download Print this page

Rohl Perrin & Rowe Bathroom U.5157 Installation & User Manual

Concealed thermostatic shower mixer

Advertisement

Quick Links

ROHL WARRANTY POLICY
All products supplied by ROHL carry warranties against manufacturing defects.
Perrin & Rowe products carry a Limited Lifetime Warranty.
ROHL LLC will provide free of charge, as its options, replacement part(s) or product (or a
comparable alternative product) to replace those which have proven defective in materials or
workmanship.
For full ROHL LLC WARRANTY please contact ROHL or visit www.rohlhome.com
CARE & MAINTENANCE
Wipe down after use to avoid water spotting and mineral build up.
Occasional cleaning with warm soapy water, followed by a polish with a soft cloth is all that is
required to keep the plated finish in good condition.
Do not use proprietary abrasive liquids, powders, or pads to clean the product. Do not use any
products with ammonia bleach or limescale remover. You will damage the plated finish and void
your guarantee.
SPARES
U.3567 - 19mm EXTENSION KIT
U.3568 - 30mm EXTENSION KIT
U.3157 - 30mm THERMO & SHUT/OFF KIT
• U.5585R
9.18555
9.13566
9.130557
9.31556
9.03559
* Where indicated please specify finish
SPARE PARTS & SERVICE
Perrin & Rowe products are manufactured in England using
quality materials, the latest technology and built to the highest
standards.
We would like to thank you for purchasing this Perrin & Rowe
product and invite you to view the comprehensive range of Perrin
3 Parker
& Rowe tapware, shower fittings, bathroom accessories, soap
Irvine
dispensers and bathroomware.
CA 92618
(714) 557-1933
Please contact us to receive our latest product catalogues or
view them online at www.rohlhome.com
www.rohlhome.com
Perrin and Rowe is a registered trademark.
• U.5157
9.181190*
9.18858
LASERMARKED
P&R - H/C
9.21207
9.12616*
• U.5158
9.12617*
9.26875
9005157U
• U.5157 (LEVER)
• U.5158 (X-TOP)
9.24875*
(x2)
9.26361*
7 . 7/8"
9.26361*
Technical Data:
• Inlet - 3/4"NPT
• Working Pressures:
Min - 1 bar(14 psi)
Max - 5 bar (75 psi)
• Wall Mounted via Fixing plate.
Temp Range:
• Temperature Hot Supply:
( 65-85ºC) 149-185ºF
• Temperature Cold supply:
( 10-22ºC) 50-72ºF
• Temperature Stability:± 1 ºC
Issue 2
The Bathroom Collection
Installation & User Guide
CONCEALED THERMOSTATIC SHOWER MIXER
USE WITH: U.5585R
• U.5585 (LEVER)
• U.5885 (LEVER)
• U.5586 (X-TOP)
• U.5886 (X-TOP)
• U.5485
7 . 1/8"
3 /4" NPT
• U.5785 (LEVER)
• U.5786 (X-TOP)
7 . 7/8"
O
Outlet
• U.5585R
Cold
Hot

Advertisement

loading
Need help?

Need help?

Do you have a question about the Perrin & Rowe Bathroom U.5157 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rohl Perrin & Rowe Bathroom U.5157

  • Page 1 All products supplied by ROHL carry warranties against manufacturing defects. Perrin & Rowe products carry a Limited Lifetime Warranty. ROHL LLC will provide free of charge, as its options, replacement part(s) or product (or a comparable alternative product) to replace those which have proven defective in materials or workmanship.
  • Page 2 The Bathroom Collection • • Installation & User Guide Congratulations on the purchase of your Perrin & Rowe Bathroom Product. Correctly installed and with sensible care, this product will give you many years of trouble free SPARES SPARES service. • U.5885 •...
  • Page 3 The Bathroom Collection • • Installation & User Guide Side view SECTION F Front view of In Wall Cavity Preparation of cavity cavity with Cavity • The cavity should be shaped as the Template Shut Off Valve Not Opening valve mudguard/cavity template removed supplied to enable the mixer to be removed for service requirements.
  • Page 4 The Bathroom Collection • • Installation & User Guide SECTION E BEFORE PROCEEDING: • If the shower body has been set too PLEASE TEST THE ROUGH KIT BY OPERATING THE SYSTEM WITH THE FLOW deeply into the cavity it may result in CONTROL ONLY, CHECKING ALL CONNECTIONS ARE SECURE.
  • Page 5: Trim Installation

    The Bathroom Collection • • Installation & User Guide SECTION D TRIM INSTALLATION Note: The Trim Plate comes Non Return Valves pre-assembled. The only loose parts are: To examine the non return valves, it will be necessary to remove the •...
  • Page 6 The Bathroom Collection • • Installation & User Guide Valve Operation SECTION C Supply Fault/Failure • Rotate the flow control lever anti-clockwise COLD a quarter turn to turn ON the shower. In order to determine and eliminate a supply fault or failure it will be necessary to •...
  • Page 7 The Bathroom Collection • • Installation & User Guide SECTION B Typical Design - System Requirements SHOWER ARM VOLUME CONTROL(S) U.3240R MUST BE ORDERED & 8" ROSE Cartridge Replacement. SEPARATELY! Should it be apparent that the cartridge Pictured to the right is a typical thermostatic is at fault (ie) unable to adjust the THERMOSTATIC system:...
  • Page 8: Troubleshooting

    The Bathroom Collection • • Installation & User Guide Troubleshooting Troubleshooting cont. SECTION A TRIM COLD SHOWER ONLY WORKING! PLATE FINISHING ACTION: Push in override stop and turn lever / crosshead • The thermostatic shower SCREWS (x2) anti-clockwise. cartridge is pre-set to give a shower temperature of (38ºC) Outcome Cause...

This manual is also suitable for:

Perrin & rowe bathroom u.5585Perrin & rowe bathroom u.5885Perrin & rowe bathroom u.5785Perrin & rowe bathroom u.5158Perrin & rowe bathroom u.5586Perrin & rowe bathroom u.5886 ... Show all