Summary of Contents for Mennekes AMTRON Professional
Page 1
Troubleshooting ENGLISH Troubleshooting procedure Error messages and solution approaches...
Page 2
Troubleshooting work in which the charging station has to be opened may only be performed by a qualified elec- trician. For charging stations that comply with calibration law, the following applies: Work on components that are subject to calibration law may only be performed by a certified service technician. Otherwise the charging station is no longer compliant with calibration law.
Error correction suc- cessful? Perform a function test with the MENNEKES test box Function test passed? Note down the article / serial number The charging station is ready for opera- and contact MENNEKES support tion again...
Page 4
Error messages and solution approaches The most common error messages are listed below. There may be error messages that are not listed here. The error messages are dependent on the firmware version. The error messages described in this document refer to firmware version 5.12.0.
Page 5
Replace charging cable. wiring issue Wrong wiring of CP and PR. f Perform a function test with the MENNEKES Vehicle signals error The vehicle signals an error (status E) or the charging cable was not detected. test box.
Page 6
Error message Cause(s) Solution approaches f Check networking. Not all DLM Slaves Disturbed communication bet- connected ween DLM Master and DLM Slaves. FW Update in pro- Firmware update. f Wait until the firmware update has been executed. gress Firmware update The firmware update could f Repeat the firmware download.
Need help?
Do you have a question about the AMTRON Professional and is the answer not in the manual?
Questions and answers