INSTALLATION

PRE-CONFIGURATION

Where to Place the MATRIX2:
The enclosure of the MATRIX2 is designed for standalone or rack-mount
configuration. The MATRIX2 is natively rack-mountable in standard
19-inch server racks. Rack-mount hardware is included with these
switches for a sturdy rack installation.
Consider the following when deciding where to place the MATRIX2:
• whether or not you intend to use the direct-access port selectors;
• the lengths of the cables attached to your keyboards, monitors,
and mice;
• the location of your CPUs in relation to your Consoles;
• and the lengths.
Cable Distance Requirements:
For PS/2 Computers:
VGA signals transmit best at distances of up to 25 feet. Beyond that
length, the probability of video degradation increases. For this reason, we
recommend that the length of the cables between the MATRIX2 and the
connected computers not exceed 25 feet.
Note:
If you need your Console to reside further than 25 feet from the
MATRIX2, we recommend using the Belkin CAT5 Extender
(F1D084) with a standard CAT5 UTP cable. By using this device,
you may increase the distance between your MATRIX2 and your
PS/2 keyboard, PS/2 mouse, and monitor by as much as 500 feet
without risking signal degradation.
For USB Computers:
USB signals can be transmitted up to 15 feet between the MATRIX2 and
the CPU. Beyond 15 feet, the probability of signal failure is likely, and this
may cause the device to fail.
Cautions and Warnings:
Avoid placing cables near fluorescent lights, air conditioning equipment,
or machines that create electrical noise (e.g., vacuum cleaners).