Summary of Contents for Assa Abloy Corbin Russwin DC8000 Series
Page 1
Installation Instructions As Easy DC8200 Series Universal Door Closers Multi-Sized 1 thru 6 Non-Hold Open with A10 Heavy Duty Arm An improperly installed or incorrectly adjusted door closer may cause property IMPORTANT: damage or personal injury; and will void product warranty. To avoid personal injury, DO NOT DISASSEMBLE THIS DOOR CLOSER BODY.
Page 2
DC8200xA10 HD Regular Arm Installation Instructions Regular Arm This P ag e Next Page ( Template ® Mark Door and Jamb (for QUIK-INSTALL bracket and arm bracket) For Vertical Dimensions use “Mounting Dimensions Chart” 1-5/8" MINIMUM CLEARANCE REQUIRED OVER DOOR *10-3/4 2-1/4 (273)
Page 3
DC8200xA10 HD Regular Arm Installation Instructions This P ag e Previous Page Next Page ( ® Mount QUIK-INSTALL Bracket Mount Closer Body to QUIK-INSTALL Bracket Start the four mounting screws into the four closer mounting holes. Place the closer onto the QUIK-INSTALL bracket with the four mounting screws inserted into the four QUIK-INSTALL bracket slots.