Page 1
P.202 RECIRCULATION PUMP Booster pump pressure for domestic water USE AND INSTALLATION MANUAL ANTARES ANTARES for water & fire S.r.l.- Via degli Alpini, 144 - 55100 Lucca - ITALIA ® for water & fire S.r.l. - Via degli Alpini, 144 - 55100 Lucca - Italia ®...
Page 2
P.064 P.202 Recirculation pump P.202 Recirculation pump Specifiche: Warnings for Children ● Any child or any adult who has any physical, sensory or mental defects or lacks of the relevant experience or knowledge, if supervised or given the method on safe use of this product as well as knowing the dangers involved, may use this product.
P.064 P.202 Recirculation pump P.202 Recirculation pump 1- Product Overview If the domestic hot water supply equipment is far away from the water point, the cold water in the pipe must be emptied in advance to enjoy the hot water, which is a waste of time and resources.
P.064 P.202 Recirculation pump P.202 Recirculation pump 4.4. After the leakage protection plug is connected, the backwater device is tested to check if the start is normal, but the idle time should not exceed 5 seconds to prevent the operation from reducing the bearing life.
Page 6
P.064 P.202 Recirculation pump P.202 Recirculation pump 1. Water heater 2. Hot water pipe 3.Cold water inlet pipe 4. Backwater device 5.Non-return value 6. Backwater pipe Figure 1 Working Process: as shown above in the installation system with backwater pipe, water he- ater [1], backwater device [4], hot water pipe [2], backwater pipe [6] installed at the far end of hot water pipe.
Page 7
P.064 P.202 Recirculation pump P.202 Recirculation pump Working Process: as shown above, in the installation system without backwater pipe, one way valve, water heater [1], backwater device [4], hot water pipe [2], cold water pipe [3] are installed in the furthest end of hot water pipe. When the backwater device [4] starts, the water heater [1] starts, and the hot water flows through the inlet outlet of the hot water pipe [2] -non-return valve [5] -cold water pipe [3] –...
P.064 P.202 Recirculation pump P.202 Recirculation pump 5.5 Product Performance Curve 14.00 12.00 10.00 8.00 6.00 4.00 2.00 0.00 10.0 12.0 14.0 16.0 18.0 Portata / (L/min ) 5.6 Mode list Mode name Mode description If the timing mode is turned on, the timing period 24 hours a day can be set sepa- rately to turn on or off in hours.
P.064 P.202 Recirculation pump P.202 Recirculation pump After the electric pump operation stops, the delay time will be set according to the user's water pipe heat preservation degree. The default value is 5 minutes, the Delay setting setting range is 1-20 min. During the delay period, the water pump does not run.
P.064 P.202 Recirculation pump P.202 Recirculation pump Debugging and menu settings: For the first time, select the appropriate line installation diagram to complete the installation, check and make sure that the line installation is correct, all valves are open normally, enter product debugging and menu settings.
P.064 P.202 Recirculation pump P.202 Recirculation pump 6.3 - Step 2 Set Temperature: If you need to change the set temperature, directly press the +/-key in the main interface, enter the “Set °C” interface (see below), after adjustment, press “OK” or 20s without operation to finish setup and return to the main menu.
Page 12
P.064 P.202 Recirculation pump P.202 Recirculation pump 6.4 - Step 4 Running Time Setup: Check the pipeline: press the red ON/OFF key to start the pump forcibly, when the pump starts, the water heater starts normally, the pipeline is normal.
Page 13
P.064 P.202 Recirculation pump P.202 Recirculation pump 6.5 - Step 5 Delay Time Change: If the pipe heat preservation effect is different, need to change the delay time of pump restarting. Press the key “Setting”, press the +/- key to move the cursor to “Delay”, press “OK”, the left digital tube will display the delay time, then press the +/-key to change the running time.
Page 14
P.064 P.202 Recirculation pump P.202 Recirculation pump 6.7 - Step 7 Reservation Change: If you want to change the reservation period of each day, press the key “Setting”, press the +/- key to move the cursor to “Preset”, press “OK” to enter the round display panel, the current selected pe- riod cursor blinks, use +/-key to move the cursor to the period you want, press “setting”...
Page 15
P.064 P.202 Recirculation pump P.202 Recirculation pump 6.9 - Step 9 Booster Function Setting: The default flow of boosting is 30L/min (equal to close). If need to change, press “Setting” and use the +/- key to move the cursor to “Boost”, press “OK”, the left digital tube will display the flow data.
Please try a few more times to find the rhythm opening is beyond the of opening and closing judgment range of 2-6 s ANTARES for water & fire S.r.l. Via degli Alpini, 144 - 55100 Lucca - ITALIA Tel. + 39 0583 473701 Fax +39 0583 494366 internet: www.antaresint.com...