Energy-saving Pipeline Canned Motor Pump EEI≤0,20 Installation and Operating Instructions ANTARES ANTARES for water & fire S.r.l.- Via degli Alpini, 144 - 55100 Lucca - ITALIA ® for water & fire S.r.l. - Via degli Alpini, 144 - 55100 Lucca - Italia ®...
Page 2
17. If the fault cannot be found and resolved as instructed cut off the electrical supply, 08. The P.064 series is not for circulating close the valves of interception and domestic hot water. contact maintenance or service center.
Page 3
NOTE: NOTE Notes or instructions to facilitate safe installation and commissioning. 2 . Overview P.064 pumps are especially The installation of the P.064 series suitable for water recirculation presents numerous advantages: for heating. The P.064 series is suitable for: •...
4. Installation P.064 P.064 Installation · Install P.064 series circulating pump, arrows on the pump housing direction of liquid flowing through the pump body. 4. Installation · When the pump is installed on the pipeline, its inlet and outlet must 4.1 Installation...
The junction box can rotate in 90 ° . To change the position of junction box, follow the operating steps below: 1.Switch the valves of inlet and outlet and conduct decompression; 2.Loosen and remove the four socket head cap screws that fix the pump body; P.064 P.064 3.Rotate the motor to the desired position and match the four screw holes;...
P.064 P.064 5. Electrical connections Electrical connection and protection should be carried out in accordance with local regulations. Warning The electric pump must be connected to earth wire. The pump must be connected with an external power switch; the minimum gap betweenall the electrodes is 3 mm.
Electric pump power display Electric pump constant speed display 6.3 Selection programm (HS1/HS2/HS3) The P.064 series circulator has 9 types of settings that can be selected using a button: 6.2 Fault code display status Fault code Fault desc Butto position...
Page 9
Since the performance is adjusted gradually, it is recommended to leave it in AUTO mode (auto- adaptation) for at least a week before changing the pump settings. • If we choose to return to AUTO mode (self-adaptation), the P.064 series pump remembers the set points of the previous AUTO mode.
Page 10
P.064 P.064 8. Night Mode 8.1 1 Basic principle Warning Before starting installation, the Installation and Operating Warning Instructions of device must be read carefully. Installation and Warning Before starting installation, the Installation and Operating use of the device must comply with local regulations and Before starting installation, the Installation and Operating Instructions of device must be read carefully.
Page 11
8.2 Night mode function Once night mode is set, the P.064 series pump will automatically alternate between normal and night mode. Switching of the P.064 series pump between normal mode and night mode depends on the temperature of the system delivery pipe.
Page 12
10.2 Gas/air leaking from the pump The P.064 series pump has the function of automatic gas discharge (vent). It is not necessary to discharge the gas before starting. The gas in the pump will cause noise. The noise will disappear after operating for a few minutes. Set the pump in HS3 mode and in short time, depending on the size and structure of the system, the gas will be discharged.
P.064 P.064 10. Settings and performance of pump 11. Pump programming and performance 1 0 . 1 R e l a t i o n s h i p b e t w e e n p u m p s e t t i n g s a n d i t s 11.1 Relationship between pump scheduling and performance p e r f o r m a n c e Water pump...
Page 14
P.064 P.064 12. Characteristic curves of the P.064 series 12.1 -Working conditions described by the curves • Test liquid: gas-free water • Density: p = 983.2 kg/m ³ • Liquid temperature + 60°C. • Kinematic viscosity u = 0.474 mm²/s (0.474.CcST) 12.2 Curve conditions...
Page 15
P.064 P.064 13. Characteristics 13.01 – Description on the badge AlfaMax RS 25/80 P.064.48 220V AC 50/60 Hz Class H TF 110 IP 42 EEI≤0,20-Part2 Number Explanations Product name Product code Voltage Insulation class Degree of protection Frequency (Hz) Degrees temperature Energy efficiency label Maximum power Power...
P.064 P.064 14. Technical information 14.1 Technical information Supply voltage 1 x 230V +6%/-10%, 50Hz, PE Motor protection The pump does not need external protection Protection Level IP42 Insulation class Ambient humidity Max. 95% Maximum pressure 1.0mpa (MPa) Liquid temperature Minimum inlet pressure ≤...
In domestic hot water, it is recommended to keep the temperature of water below 65℃ so as to reduce scaling P.064 P.064 13.2 Installation dimension 14.2 Space encumbrance Voltage Material Dimension(mm) Power Model input (W) Cast Stainless 220~240V/50Hz Plastic Copper Iron steel ●...
P.064 P.064 14. Fault checklist 15. Problem solving Warning Warning: Before carrying out any maintenance and repairs on the electric pump, make sure that the power is disconnected and that no one accidentally reactivated it Before carrying out any maintenance and repair to the electric pump, make sure the power is disconnected and will not be accidentally switched on.