Extreme Networks, Inc. reserves the right to make changes in specifications and other information contained in this document and its website without prior notice. The reader should in all cases consult representatives of Extreme Networks to determine whether any such changes have been made.
Install a Transceiver................................21 Connect Cables to Transceiver Ports........................21 Ethernet Ports LED Information..........................22 Regulatory and Compliance....................23 Safety Guidelines....................................23 Battery Notice..................................... 24 Federal Communications Commission (FCC) Notice..................24 Industry Canada, Class A................................24 Conformitè Europëenne (CE) Notice..........................25 Extreme Networks Universal Compute Platform Appliance 2130C...
Page 4
Japan (VCCI) - Voluntary Control Council for Interference Class A ITE........... 25 BSMI Statement - Taiwan................................25 CCC Statement - China................................27 Supplement to Product Instructions..........................27 Hazardous Substances.................................27 European Waste Electrical and Electronic Equipment (WEEE) Notice..........28 Index..............................29 Extreme Networks Universal Compute Platform Appliance 2130C...
Abstract The Extreme Networks Universal Compute Platform 2130C Installation Guide provides detailed procedures for setting up the 2130C appliance for medium deployments. Key features include front and back panel layouts with LED indicators, USB ports, and data ports supporting various GbE speeds. Installation instructions cover pre-installation...
When a feature, function, or operation pertains to a specific hardware product, the product name is used. When features, functions, and operations are the same across an entire product family, such as Extreme Networks switches or SLX routers, the product is the switch or the router .
When a backslash separates two lines of a command input, enter the entire command at the prompt without the backslash. Documentation and Training Find Extreme Networks product information at the following locations: Extreme Networks Universal Compute Platform Appliance 2130C...
Some software files have been licensed under certain open source licenses. Information is available on the Open Source Declaration page. Training Extreme Networks offers product training courses, both online and in person, as well as specialized certifications. For details, visit the Extreme Networks Training page. Help and Support...
You can modify your product selections or unsubscribe at any time. Send Feedback The User Enablement team at Extreme Networks has made every effort to ensure that this document is accurate, complete, and easy to use. We strive to improve our documentation to help you in your work, so we want to hear from you.
It fits a 19-inch rack and features four data ports, four USB ports, and two Inter-Cluster- Connect (ICC) ports. The 2130C is designed to host ExtremeCloud Edge - Self Orchestrated applications. Important Only qualified personnel must perform installation procedures.
Two USB 3.2 ports • Two 10 Gb RJ45 Ethernet ports • Two 25 Gb SFP28 Ethernet ports LEDs The 2130C has the following status LEDs on the front of the chassis: • Information LED • ICC2 LED • ICC1 LED •...
Use the information in the following sections to identify the hardware features located on the front and rear panel. Figure 1: 2130C Front Panel Layout The 2130C has the following hardware features located on the front panel. Table 4: 2130C Front Panel Callout Description...
Power supply warning events where power supply 1Hz Blinking Amber continues to operate — high temp, high power, high current, or slow fan. Power supply critical event causing a shutdown, Amber failure, OCP, OVP, or fan fail. Extreme Networks Universal Compute Platform Appliance 2130C...
17 Connect to a Power Source on page 17 Use the information in the following sections to install the 2130C appliance. Installation Workflow The following table lists the installation tasks. Use this information as a guide when you install the 2130C.
Verify Box Contents Verify Box Contents About This Task The 2130C ships with everything needed for a basic installation. Confirm that you have received the following items before you install your appliance. Note The power cord needs to be purchased separately for the respective country where you are deploying the device.
Have the replacement fan on hand so that you can complete the replacement quickly. The appliance overheats if it isn't cooled for an extended time. The cooling fan is at the rear of the appliance. About This Task To replace a cooling fan: Extreme Networks Universal Compute Platform Appliance 2130C...
2. Plug the other end of the cables into grounded electrical outlets or to separate power sources such as an uninterrupted power supply (UPS) or a power distribution unit (PDU). 3. Power On the appliance. The power button is on the front control panel. Extreme Networks Universal Compute Platform Appliance 2130C...
• Data plane settings About This Task You can configure the 2130C appliance from the appliance console port if you have physical access to it. Configuration is asynchronous, but you can see the boot up process. The console port is on the appliance's front panel. See Front and Back Panel Information.
The Universal Compute Platform login screen opens. 10. Enter admin and the credentials that were created when setting up the installation wizard. Note An installation wizard is available to help configure the 2130C for new deployments. Configure the Management Interface from the Inter-Cluster-Connect Port Before You Begin You will need a laptop.
Connect the Data Ports About This Task The 2130C data ports 1 and 2 are 1/10 GbE RJ45 ports. Ensure that the device to be connected at the other end of the segment is powered on. To connect a twisted pair cabling: Procedure 1.
Configuration Install a Transceiver 3. If a link is not established, contact Extreme Networks. Install a Transceiver About This Task Data ports 3 and 4 provide SFP28 ports that can support 1, 10, and 25Gbps transceivers. Refer to the transceivers and cables datasheet for a list of pluggable transceivers supported for 2130C.
LED pattern Status Network speed (right) Solid amber Less than 25,000 Mbps (25 Gbps) Solid green 25,000 Mbps (25 Gbps) Link activity (left) No link Solid green Active link Blinking green Data traffic activity Extreme Networks Universal Compute Platform Appliance 2130C...
27 European Waste Electrical and Electronic Equipment (WEEE) Notice on page 28 The following sections detail the regulatory information for the 2130C appliance. Safety Guidelines Learn about the safety guidelines that are intended to protect your personal safety and prevent damage to the equipment.
“Digital Apparatus,” ICES-003 of the Canadian Department of Communications. Cet appareil numérique respecte les limites bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel Extreme Networks Universal Compute Platform Appliance 2130C...
BSMI Statement - Taiwan This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Extreme Networks Universal Compute Platform Appliance 2130C...
This product complies with the requirements of Directive 2011/65/EU and its amendments of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. Extreme Networks Universal Compute Platform Appliance 2130C...
4. It is the user's responsibility to utilize the available collection system to ensure WEEE is properly treated. For information about the available collection system, please contact Extreme Environmental Compliance at Green@extremenetworks.com. Extreme Networks Universal Compute Platform Appliance 2130C...
Need help?
Do you have a question about the 2130C and is the answer not in the manual?
Questions and answers