Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Foldi 3S and is the answer not in the manual?

Questions and answers

Summary of Contents for UREVO Foldi 3S

  • Page 1 Model.URTM037 Foldi 3S Treadmill USER MANUAL...
  • Page 3 • • • Urevo YouTube Video...
  • Page 5 Accessories...
  • Page 6: How To Use

    HOW TO USE Unfolded To Run (Speed range : 0.6- 7.6mph) 1. Unbox to take out the treadmill with the related accessories, then place the treadmill on flat ground. 2. Counterclockwise roating fold lever 3. Open the armrest horizontally to unlock. upwards 4.
  • Page 7 safety stop (cord type) In any emergency occurs, treadmill stops automatically and show "E10" when the safety key is pulled out from the console. NOTE: Find the clip (A) onto the waistband of your clothes, another key (B) magnetic attracted under console. Level 0...
  • Page 8: Operation

    Standby Mode OPERATION When the treadmill is paused during operation, if the pause is not released within 10 minutes, it will return to the standby interface "0000", and at the same time, the previous operation data will be reset to zero; if there is no operation for 10 minutes on the standby interface, it will enter the sleep mode;...
  • Page 9: Care And Maintenance

    CARE & MAINTENANCE Symptom : walk belt off centered or slips. Centering walk belt process as follow : 1. Power off treadmill and unplug the power cord . 2. Manual centering process as follow: • If the walk belt has shifted to left, use the hex tool to turn the left idler roller screw clockwise 1/4 of a turn(refer to figure 1).
  • Page 10: Error Code

    Belt lubrication process, follow instruction below to ERROR CODE lubricate belt. 1. Power off treadmill and unplug power cord. 2. Using the hex tool, turn both idler roller screws counterclockwise till belt loosen and lifting easily. Error Code Fault Analysis Resolutions Tips: please markdown hex tool rotating cycles Unscrew motor hood and verify connection between...
  • Page 11: Troubleshooting

    TROUBLESHOOTING Problem Fault Analysis Resolutions 1. Power rock switch 1. Replace new power rock switch if it doesn't dyfunction. light on. No working 2. Power supply 2. Make sure that power cord is plugged into interrputed. properly grounded outlet. 3.Power cord damaged. 3.