3 Pin Input/Output Harness; Entry Illumination Detail - Prestige 1286568 Installation Instructions Manual

4 channel remote start / keyless entry system
Table of Contents

Advertisement

3 Pin Input/Output Harness:

Dark Blue/Black Trace Wire: External Trigger Input
The Dark Blue/Black trace wire allows the remote start unit to be activated from an external source. The
intent of this wire is to allow the unit to be controlled from a "POSSE/CAR-LINK" paging system or similar
device. When this wire receives a ground pulse, the unit will start the vehicle. Connect this wire to a
ground pulsed output from the controlling circuit.
Green w/ White Trace Wire: Entry Illumination Ground Output
This wire provides a 30 second ground output (300 mA Max.) whenever the remote is used to unlock the
doors . This wire should be connected to an external relay, and wired to the vehicles interior entry lighting
whenever the optional Interior Illumination circuit is desired. See below for relay wiring details.
Black w/ White Trace Wire: 300 mA Horn Output
The black w/ white trace wire is provided to beep the vehicle's horn. This is a transistorized low current
output, and should only be connected to the low current ground output from the vehicle's horn switch.
If the vehicle uses a + 12 VDC horn switch, then connect the black w/ white trace wire to terminal 86 of the
AS 9256 relay ( or an equivalent 30 Amp automotive relay ), and connect relay terminal 85 to a fused + 12
VDC battery source. Connect relay terminal 87 to the vehicle's horn switch output, and connect relay
2
terminal 30 to a fused + 12 VDC battery source.
1. RF Programmable Features:
Feature
1 Flash
1st Door Lock O/P
1S/1S
2nd Auto Locks
On
3rd Auto Unlock
Dr. Door
4th Run Time
5 Min
5th Lights
On Steady
6th Horn Timing Select
10mS
7th Input Check
Voltage
8th Check Level
> 0.5V B4 Start
9th Ign 2 Crank
Off
10th Diagnostics
Off
11 Crank Time
0.8Sec
12th Gas/Diesel
Gas
13th 2nd Step Unlock
On
NOTE: When selecting Diesel operation, (Feature #11), over gasoline, the only change is to the ignition
circuits. When Diesel is selected, the ignition circuits will power up for X seconds, as dictated by
the feature selection, before the start circuit. The intent of this feature is to allow the glow plug
warming required by some diesel engines. If your vehicle is a instant start diesel, it is not necessary
to activate this feature.

Entry Illumination Detail

2 Flash
3 Flash
3.5S/3.5S
1S/Dbl1S
Off
All Doors
Off
10 Min
15 Min
Flash
16mS
30mS
Tach
< 0.5V B4 Start
On
On
1.0 Sec
1.5 Sec
Diesel 10
Diesel 15
Off
13
4 Flash
Default
1S/1S
Off
Off
20 Min
10 Min.
Steady
40mS
16mS
Tach
>0.5
On
Off
2.0 Sec
1.0
Diesel 20
Gas
Off
128-6568
13 of 20