Seasonal Shutdown Instructions
UV Modules
• Turn the Main Disconnect switch to the OFF position on the Ballast & ICA
enclosures. Leave the main power to the Ballast & ICA enclosures ON so
that the climate control will remain operational.
• Lift all of the modules to the highest position and insert the module safety
lock pins.
• Turn the power at the module lift and electric wipe control enclosures OFF.
• Remove module covers if available and clean the modules thoroughly with
Lime Away®, CLR®, or similar mild acidic cleaning solution to prevent scaling
on the quartz sleeves.
• If possible, all cables should remain plugged in to prevent damage to the
connectors.
• Stainless steel module covers should be mounted back on the module if
available.
• Wrap the cable connections with plastic to prevent damage from dust, dirt,
or water intrusion. Ideally wrap the Duron UV module with Wedeco's weather
resistant acrylic bags.
• Wedeco can provide weather resistant bags to cover the entire UV module
and protect it against rain, ice, dust and dirt intrusion. Contact our
aftermarket team (Ref No 14-659175) at 704-409-9793 or via email at
aftermarket@xyleminc.com for more details or to place an order.
• For additional storage recommendations, e.g. if the system will be out of
service for longer than a season, please contact the Wedeco Service Team.

Advertisement

loading
Need help?

Need help?

Do you have a question about the Wedeco DURON and is the answer not in the manual?

Questions and answers

Summary of Contents for Xylem Wedeco DURON

  • Page 1 Wedeco DURON UV System Seasonal Shutdown Instructions UV Modules • Turn the Main Disconnect switch to the OFF position on the Ballast & ICA enclosures. Leave the main power to the Ballast & ICA enclosures ON so that the climate control will remain operational.
  • Page 2: Control Panels

    • The submerged probe should be disconnected, removed from the channel, and thoroughly cleaned. Store the probe in a clean dry place. • The remaining cable connector should be sealed and protected from dust, dirt, and water intrusion. Wedeco DURON UV System Seasonal Site Shutdowns Instructions...
  • Page 3: General Notes

    • Fan filters should be checked for any obstructions and cleaned or replaced if needed. • If the system is equipped with air conditioning units, check the filters and clean or replace them as necessary. Wedeco DURON UV System Seasonal Site Shutdowns Instructions...
  • Page 4 • Turn the power ON to the UV system. • Place the system in the Automatic mode. • Once the system has been running for 15 minutes the flow can be started through the channel Wedeco DURON UV System Seasonal Site Shutdowns Instructions...
  • Page 5 Xylem, Inc. 14125 South Bridge Circle Charlotte, NC 28273 Tel 704.409.9700 Fax 704.295.9080 855-XYL-H2O1 (855-995-4261) © 2017 Xylem, Inc. All rights reserved. Flygt is a trademark are trademarks of Xylem Inc. or one of its subsidiaries.