Download Print this page

NEC DSX-160 SYSTEM LOAD FACTOR Hardware Manual page 2

Hide thumbs Also See for DSX-160 SYSTEM LOAD FACTOR:

Advertisement

System Configuration
Description
CPU Card
16ESIU Card
8SLIU Card
16SLIU Card
8COIU Card
16COIU Card
T1/E1/PRI Card
Item 1: Load Type Totals
(Cannot exceed Item 2: Power Supply Capacity.)
If you have one power supply installed, the capacity is:
If you have two power supplies installed, the capacity is:
If you have three power supplies installed, the capacity is:
Notes:
DSX-80 can only have 1 power supply.
DSX-160 can have up to 3 power supplies. You cannot have more than two 16ESIU Cards per power supply,
regardless of System Load Factor calculations.
Exceeding the allowed Load Type Total (Item 1) will cause the system's power supplies to automatically shut down
and/or cause erratic system operation.
The total of all station, line, DSS Console, and voice mail ports cannot exceed 160.
20 ◆ Components
DSX-80/160 System Load Factor Worksheet
Qty
Load
1
12
8
5
10
3
6
8
Item 2: Power Supply Capacity
Load Type
5 VDC
Total
12
5 VDC = 40
40 VDC = 48
5 VDC = 80
40 VDC = 80
5 VDC = 120
40 VDC = 120
DSX-80/160 Hardware Manual
40 VDC
Load
Total
0
0
20
8
16
0
0
0

Advertisement

loading

This manual is also suitable for:

Dsx-80