Toshiba RAV-HB121BTP-UL Owner's Manual
Hide thumbs Also See for RAV-HB121BTP-UL:

Advertisement

Quick Links

AIR CONDITIONER (SPLIT TYPE)
Owner's Manual
Indoor Unit
Model name:
Concealed Duct Type
RAV-HB121BTP-UL
RAV-HB181BTP-UL
RAV-HB241BTP-UL
RAV-HB301BTP-UL
RAV-HB361BTP-UL
RAV-HB421BTP-UL
RAV-HB481BTP-UL
OM_1128950203.indb 1
OM_1128950203.indb 1
For commercial use
Pour usage commercial
Para uso comercial
1128950203
Owner's Manual
1
English
Manuel du Propriétaire
17
Français
Manual del Propietario
32
Español
19/4/2567 BE 13:50
19/4/2567 BE 13:50

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RAV-HB121BTP-UL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Toshiba RAV-HB121BTP-UL

  • Page 1 1128950203 AIR CONDITIONER (SPLIT TYPE) Owner’s Manual Indoor Unit For commercial use Pour usage commercial Model name: Para uso comercial Concealed Duct Type RAV-HB121BTP-UL RAV-HB181BTP-UL RAV-HB241BTP-UL RAV-HB301BTP-UL RAV-HB361BTP-UL RAV-HB421BTP-UL RAV-HB481BTP-UL Owner’s Manual English Manuel du Propriétaire Français Manual del Propietario Español...
  • Page 2: Table Of Contents

    – 1 – Contents Original instruction ADOPTION OF NEW REFRIGERANT 1 Precautions for safety ....................3 This Air Conditioner uses R454B an environmentally friendly refrigerant. 2 Part names ........................7 According to UL 60335-1 3 Wired remote controller ....................8 This appliance is not intended for use by persons (including 4 Operation .........................
  • Page 3: Warning Indications On The Air Conditioner Unit

    Thank you for purchasing this air conditioner. These safety cautions describe important matters concerning safety to prevent injury to users or other people Please read carefully through these instructions that contain important information and ensure that you understand and damages to property. Please read through this manual after understanding the contents below (meanings of them.
  • Page 4: Precautions For Safety

    – 3 – ■ Warning indications on the air conditioner unit Precautions for safety Warning indication Description The manufacturer shall not assume any liability for the damage caused by not observing the description of this manual. WARNING WARNING ELECTRICAL SHOCK HAZARD WARNING Disconnect all remote ELECTRICAL SHOCK HAZARD...
  • Page 5: Installation

    • The air conditioner must be transported in stable condition. Operation If any part of the product broken, contact your dealer. • Before opening the electrical control box cover of the indoor unit • When the air conditioner must be transported by hand, carry it by or service panel of the outdoor unit, set the circuit breaker to the two or more people.
  • Page 6 – 5 – • When the air conditioner is operated with a combustion appliance • If the fan guard is damaged, do not approach the outdoor unit but in the same place, ventilate the room sufficiently. Poor ventilation set the circuit breaker to the OFF position, and contact a qualified causes oxygen shortage.
  • Page 7 • Do not leave flammable sprays or other flammable materials near CAUTION the air conditioner, and do not spray flammable aerosol directly to To disconnect the appliance from the mains supply. the air conditioner. They may catch fire. • This appliance must be connected to the mains by means of a •...
  • Page 8: Part Names

    – 7 – ■ Information on the transportation, handling and storage of the Part names carton ◆ Examples of indication on the carton ■ Indoor unit Symbol Description Symbol Description Air discharge Connect a discharge duct. Keep dry Do not drop Electrical control box The ground screw is provided in the electrical control box.
  • Page 9: Wired Remote Controller

    Switching between the detailed display and simple display Wired remote controller (air conditioner main screen only) You can change the main screen to the simple display, depending on the “Display mode” setting. For details on changing “Display mode”, refer to “Display setting” in “Initial setting” in the Installation Manual. This remote controller can control the operation of up to 8 indoor units.
  • Page 10: Operation

    – 9 – ■ Icon list Operation ■ Running operation * Some operation modes are not available depending on the type of indoor unit. ■ Operations Press [ ON/OFF] to start operations The operation LED lights. ▼ Air conditioner Press [ ] and [ ] to select the item you want Displayed when “Energy saving operation”...
  • Page 11 ■ ■ Changing the fan speed Changing the temperature Press [ ] and [ ] to switch to the Press [ ] and [ ] to switch to the “Set temp.” “Fan Speed” screen screen Press [ ] and [ ] to select fan speed Press [ ] and [...
  • Page 12 – 11 – ■ 46°F (8°C) operation (For object pre-heating) Press [ Set/Fix] The air conditioner can control the heating temperature to about 46°F (8°C) in the heating mode. The 46°F (8°C) heating operation requires settings with the wired remote controller. Ask the installer or dealer for the settings according to the installation manual of the indoor unit.
  • Page 13: Off Reminder Timer

    Off reminder timer Energy saving ■ Off reminder timer Set for the energy saving operation: Energy saving operation, Set temp. range limit, Return back and Saving operation. Select “Energy saving”, and press [ Set/Fix] In the “Off reminder timer” screen, press ] and [ ] to select “Off reminder timer”...
  • Page 14: Maintenance

    – 13 – Energy saving ratio Maintenance Carry out the setting operation while the indoor unit is stopped. (Turn off the air conditioning unit before starting the setting operation.) Turn off the power before maintenance. In the “Energy saving operation” screen, press [ ] and [ ] to select...
  • Page 15: Troubleshooting

    NOTE Troubleshooting For environmental conservation, it is strongly recommended that the indoor and outdoor units of the air conditioner in use be cleaned and maintained regularly to ensure efficient operation of the air conditioner. When the air conditioner is operated for a long time, periodic maintenance (once a year) is recommended. Check the points described below before requesting repair.
  • Page 16: Operations And Performance

    – 15 – ■ Confi rmation and check Operations and performance Check code When an error occurs in the air conditioner, the check code and the indoor unit number flash on ▼ Check before running ▼ Protective device Indoor unit number the display of the remote controller.
  • Page 17: Installation

    Installation Do not install the air conditioner in the following places • Do not install the air conditioner in any place within 39.4" (1 m) from a TV, stereo, or radio set. If the unit is installed in such place, noise transmitted from the air conditioner affects the operation of these appliances. •...
  • Page 18 144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANGPATHUMTHANI, PATHUMTHANI, 12000 THAILAND 1128950203 OM_1128950203.indb 17 OM_1128950203.indb 17 19/4/2567 BE 13:50 19/4/2567 BE 13:50...

Table of Contents