AIR CONDITIONER (SPLIT TYPE)
Installation Manual
Indoor Unit
Model name:
High-Wall Type
RAV-HB301KRTP-UL
RAV-HB361KRTP-UL
1130850104_EN-FR-ES.indb c1
1130850104_EN-FR-ES.indb c1
For commercial use
Pour usage commercial
Para uso comercial
Owner's Manual
Manuel du proprietaire
Manual del propietario
1130850104
1
English
47
Français
85
Español
4/21/2567 BE 17:30
4/21/2567 BE 17:30

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RAV-HB301KRTP-UL and is the answer not in the manual?

Questions and answers

Summary of Contents for Toshiba RAV-HB301KRTP-UL

  • Page 1 AIR CONDITIONER (SPLIT TYPE) Installation Manual Indoor Unit Model name: For commercial use Pour usage commercial Para uso comercial High-Wall Type RAV-HB301KRTP-UL RAV-HB361KRTP-UL Owner’s Manual English Manuel du proprietaire Français Manual del propietario Español 1130850104 1130850104_EN-FR-ES.indb c1 1130850104_EN-FR-ES.indb c1 4/21/2567 BE 17:30...
  • Page 2: Table Of Contents

    Installation Manual Please read this Installation Manual carefully before installing the Air Conditioner. This Manual describes the installation method of the indoor unit. For installation of the outdoor unit, follow the Installation Manual attached to the outdoor unit. ADOPTION OF NEW REFRIGERANT This Air Conditioner uses R454B an environmentally friendly refrigerant.
  • Page 3 Installation Manual Thank you for purchasing this air conditioner. Please read carefully through these instructions that contain important information and ensure that you understand them. After reading these instructions, be sure to keep them in a safe place together with the Owner’s Manual and Installation Manual supplied with your product.
  • Page 4 Installation Manual Definition of Protective Gear When the air conditioner is to be transported, installed, maintained, repaired or removed, wear protective gloves and ‘Safety’ work clothing. In addition to such normal protective gear, wear the protective gear described below when undertaking the special work detailed in the table below.
  • Page 5: Warning Indications On The Air Conditioner Unit

    Installation Manual Warning indications on the air conditioner unit WARNING WARNING ELECTRICAL SHOCK HAZARD ELECTRICAL SHOCK HAZARD Disconnect all remote Disconnect all remote electric power supplies before servicing. electric power supplies before servicing. WARNING WARNING Moving parts. Moving parts. Do not operate unit with grille Do not operate unit with grille removed.
  • Page 6: Precautions For Safety

    Installation Manual PRECAUTIONS FOR SAFETY Ensure that all Local, National and International regulations are satisfied. Read this “PRECAUTIONS FOR SAFETY” carefully before Installation. The precautions described below include the important items regarding safety. Observe them without fail. After the installation work, perform a trial operation (test run) to check for any problem.
  • Page 7: Selection Of Installation Location

    Installation Manual ’ Selection of installation location – 6 – 6-EN 1130850104_EN-FR-ES.indb 6 1130850104_EN-FR-ES.indb 6 4/21/2567 BE 17:30 4/21/2567 BE 17:30...
  • Page 8: Installation

    Installation Manual Installation Install the air conditioner securely in a location where the base can sustain the weight adequately. If the strength is not enough, the unit may fall down resulting in injury. Follow the instructions in the Installation Manual to install the air conditioner. Failure to follow these instructions may cause the product to fall down or topple over or give rise to noise, vibration, water leakage or other trouble.
  • Page 9 Installation Manual Connect earth wire. (grounding wire) Incomplete grounding causes an electric shock. Do not connect grounding wires to gas pipes, water pipes, and lightning conductor or telephone grounding wires. After completing the repair or relocation work, check that the grounding wires are connected properly.
  • Page 10 Installation Manual Explanations given to user Upon completion of the installation work, tell the user where the circuit breaker is located. If the user does not know where the circuit breaker is, he or she will not be able to turn it off in the event that trouble has occurred in the air conditioner.
  • Page 11 Installation Manual CAUTION New refrigerant air conditioner installation This air conditioner adopts refrigerant R454B which does not destroy ozone layer. To disconnect the appliance from main power supply. The installation fuse (all types can be used) must be used for the power supply line of this air conditioner.
  • Page 12: Accessory Parts

    Installation Manual ACCESSORY PARTS ’ l l a (For hand over to customers) s ’ (For hand over to customers) l l a Wireless remote controller Remote controller holder Mounting screw Ø5/32 (4 mm) × 1.0 (25 mm) Flat head wood screw Ø1/8 (3.1 mm) ×...
  • Page 13: Selection Of Installation Place

    Installation Manual SELECTION OF INSTALLATION PLACE WARNING Install the air conditioner at enough strong place to withstand the weight of the unit. CAUTION Do not install the air conditioner in a location subject to a risk of exposure to a combustible gas.
  • Page 14: Installation Diagram Of Indoor Unit

    Installation Manual Installation diagram of Indoor unit For the rear left, bottom left and left piping Packing material Wall Split Hook Installation plate SPACER Hook Split out 2 pieces of SPACER from indoor unit packing material, insert between the indoor unit and wall to tilt the indoor unit for better operation.
  • Page 15: Wireless Remote Controller

    Installation Manual Wireless remote controller A place where there are no obstacles such as a curtain that may block the signal from the indoor unit. Do not install the remote controller in a place exposed to direct sunlight or close to a heating source, such as a stove.
  • Page 16 Installation Manual Installation of eletrical cover 2 holes type REQUIREMENT In case of group control, electrical cover 1 hole type need to change to electrical cover 2 holes type. Step to remove the electrical cover 1 hole. 1) The electical cover 1 hole can be removed by removing the screw securing the electical cover 1 hole and them pulling out the electical cover 1 hole.
  • Page 17: Cutting A Hole And Mounting Installation Plate

    Installation Manual CUTTING A HOLE AND MOUNTING INSTALLATION PLATE Cutting a hole When the installation plate is directly mounted on the wall In case of installing the refrigerant pipes from the rear: 1. Securely fit the installation plate onto the 1.
  • Page 18: Piping And Drain Hose Installation

    Installation Manual PIPING AND DRAIN HOSE INSTALLATION Piping and drain hose forming * Since dewing results in a machine trouble, make sure to insulate both connecting pipes. (Use polyethylene foam as insulating material.) Rear right Rear left Bottom left Left Bottom right Right 1.
  • Page 19 Installation Manual How to remove the drains cap Clip the drain cap by needle-nose pliers and pull out. Drain cap How to fix the drains cap 1) Insert hexagonal wrench (dia. 0.2 (4 mm)) in a centre head. Drain cap 2) Firmly insert drains cap.
  • Page 20 Installation Manual In case of bottom right or bottom left piping After scribing slits of the front panel with a knife or a marking-off pin, cut them with a pair of nippers or an equivalent tool. Slit Left-hand connection with piping Bend the connecting pipe so that it is laid within 1.7 (43 mm) above the wall surface.
  • Page 21: Indoor Unit Fixing

    Installation Manual INDOOR UNIT FIXING DRAINAGE 1. Pass the pipe through the hole in the wall, 1. Run the drain hose sloped downwards. and hook the indoor unit on the installation NOTE plate at the upper hooks. 2. Swing the indoor unit to right and left to Hole should be made at a slight downward confirm that it is firmly hooked up on the slant on the outdoor side.
  • Page 22: Refrigerant Piping

    Installation Manual REFRIGERANT PIPING Refrigerant Piping Permissible Piping Length and Height Difference 1. Use copper pipe with 0.03 (0.8 mm) or more thickness. (In case pipe size is They vary according to the outdoor unit. dia. 5/8 (15.9 mm), with 0.04 (1.0 mm) or For details, refer to the Installation Manual more.) attached to the outdoor unit.
  • Page 23 Installation Manual * In case of flaring for R454B with Piping with outdoor unit the conventional flare tool, pull it Shape of valve differs according to the outdoor out approx. 0.02 (0.5 mm) more unit. than that for R22 to adjust to the For details of installation, refer to the Installation specified flare size.
  • Page 24: Gas Leak Check

    Installation Manual Gas leak check Check with a leak detector or soap water whether gas leaks or not, from the pipe connecting section or cap of the valve. REQUIREMENT Use a leak detector manufactured exclusively HFC refrigerant (R454B, R134a, etc.). Wireless remote controller A-B selection Using 2 wireless remote controllers for the...
  • Page 25: Electrical Connection

    Installation Manual ELECTRICAL CONNECTION WARNING Use the specified wires for wiring connect the terminals. Securely fix them to prevent external forces applied to the terminals from affecting the terminals. Incomplete connection or fixation may cause a fire or other trouble. Connect earth wire.
  • Page 26 Installation Manual CAUTION When connecting to the central control device dedicated to TCC-Link, it is necessary to change to TCC-Link using a wired remote controller. Set according to the Communication type procedure of “11 Applicable controls”. Indoor unit Indoor unit Indoor unit Indoor unit Remote...
  • Page 27: Wiring Diagram

    Installation Manual Wiring between indoor unit and outdoor unit Figure below shows the wiring connections between the indoor and outdoor units and between the indoor units and remote controller. The wires indicated by the broken lines or dot-and-dash lines are provided at the locally. Refer to the both indoor and outdoor unit wiring diagrams.
  • Page 28: Wiring Connection

    Installation Manual Wiring Connection Power supply terminal block How to connect the power supply wiring Terminal cover and control wiring The power supply wire and the control wire can be connected without removing the front panel. Terminal block for REQUIREMENT communication/ remote controller Connect the power supply wire after connecting...
  • Page 29 Installation Manual Wiring connection (twin, triple, Clamp the wired remote controller wire double twin system) with the cord clamp. Install the clamp base with a screw. Connect a header unit by following the Insert the system interconnection wire procedure of wiring connection for single fully into the terminal block and secure it system.
  • Page 30 Installation Manual Wiring connection (twin, triple, Clamp the wired remote controller wire double twin system) with the cord clamp. Install the clamp base with a screw. Connect a header unit by following the Insert the system interconnection wire procedure of wiring connection for single fully into the terminal block and secure it system.
  • Page 31: Applicable Controls

    Installation Manual APPLICABLE CONTROLS Push [ Menu] to open the “Menu” REQUIREMENT When the air conditioner is used for the first Push and hold [ Menu] and [ ] at time, it will take some moments after the power the same time to open “Field setting has been turned on before the remote control menu”...
  • Page 32: Filter Sign Setting

    Installation Manual Installing indoor unit on high Filter sign setting ■ ■ ceiling According to the installation condition, the lighting time of the fi lter sign (Notifi cation of fi lter cleaning) When an indoor unit is installed on a ceiling higher can be changed.
  • Page 33 Installation Manual To secure better effect of heating TA sensor selection ■ ■ When it is diffi cult to obtain satisfactory heating The temperature sensor of the indoor unit senses due to installation place of the indoor unit or room temperature usually. Set the remote control structure of the room, the detection temperature sensor to sense the temperature around the of heating can be raised.
  • Page 34: Group Control

    Installation Manual Group control Simultaneous twin, triple or double twin system A combination with an outdoor unit allows simultaneous ON / OFF operation of the indoor units. The following system patterns are available. - Two indoor units for the twin system - Three indoor units for the triple system - Four indoor units for the double-twin system Twin system...
  • Page 35 Installation Manual Group control for system of multiple units One remote controller can control maximum 8 indoor units as a group. Group control in single system Outdoor unit Outdoor unit Outdoor unit Outdoor unit Outdoor unit Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit...
  • Page 36 Installation Manual [Procedure example] After fi nishing setting the data of the code (DN), push [ Set/Fix]. Manual address setup procedure While the operation stops, change the setup. “Continue?” is displayed. (Stop the operation of the unit.) <Indoor unit address> To set the data of Indoor unit address, Menu(1/3) push [...
  • Page 37: Central Control System

    Installation Manual Central control system To not do other settings, push Return]. Air conditioners at multiple locations can be If the “Indoor unit” or “Outdoor unit” controlled individually for each refrigeration selection screen is displayed before “ ” system from a control room. is displayed, push [ Return].
  • Page 38 Installation Manual Centrally control the system by the SDI series on their own setting for the terminating resistor is required. Use switch SW01 for the setting. Make the terminating resistor setting only for the indoor unit with the smallest line address number. Central Central control...
  • Page 39 Installation Manual How to set the SW01 Remove the electrical control box cover and set bit1 of SW01 on the board to ON. Remove the front panel. (Do not touch SW02 as it is used for other Before removing the front panel, direct the setting.) horizontal louver to the direction shown in the figure below.
  • Page 40 Installation Manual Centrally control the system by connecting to the TCC-LINK central control system. Setting central control addresses When air conditioners of the SDI, DI series are connected to the TCC-LINK central control system for central control using this product, set the addresses of indoor units using the following procedure. Completion of ELECTRIC WORK construction System power ON...
  • Page 41: Test Run

    Installation Manual TEST RUN Before test run Wired remote control ■ Before turning on the circuit breaker, carry out • the following procedure. 1) By using 500 V-megger, check that resistance of 1 MΩ or more exists between the terminal block L1 to L2 and the ground (grounding).
  • Page 42 Installation Manual In case of wireless remote controller (Forced test operation is performed in a different way) REQUIREMENT For the operation procedure, be sure to follow the Owner’s Manual. Finish the forced cooling operation in a short time because it applies excessive strength to the air conditioner.
  • Page 43: Maintenance

    Installation Manual MAINTENANCE Daily maintenance Mount the air filter Cleaning of air filter Turn on the circuit breaker, then push the is displayed on the remote controller, maintain button on the remote controller to the air filter. start the operation. Push the button to stop the operation, After cleaning, perform “Filter Sign Reset”.
  • Page 44 Installation Manual CAUTION Do not start the air conditioner while leaving air filter removed. Push the filter reset button. ( indication will be turn off.) Periodic maintenance For environmental conservation, it is strongly recommended that the indoor and outdoor units of the air conditioner in use be cleaned and maintained regularly to ensure efficient operation of the air conditioner.
  • Page 45: Troubleshooting

    Installation Manual TROUBLESHOOTING Confirm and check Contact information for repairs ■ ■ You can look for contact information for repairs. Check code Indoor unit number When a trouble occurs in the air conditioner, the In the “Information” screen, check code and the indoor unit number fl ash on push [ ] and [ ] to select...
  • Page 46 Installation Manual CAUTION Do not start the air conditioner while leaving air filter removed. Push the filter reset button. ( indication will be turn off.) Periodic maintenance For environmental conservation, it is strongly recommended that the indoor and outdoor units of the air conditioner in use be cleaned and maintained regularly to ensure efficient operation of the air conditioner.
  • Page 47 Installation Manual Error codes and parts to be checked Wired Wireless remote controller remote Sensor block display of controller receiving unit Judging Air conditioner display Main defective parts Parts to be checked / error description device status Operation Timer Indication Ready Flashing GR GR OR...
  • Page 48 Installation Manual Wired Wireless remote controller remote Sensor block display of controller receiving unit Judging Air conditioner display Main defective parts Parts to be checked / error description device status Operation Timer Indication Ready Flashing GR GR OR Room temp. sensor (TA), indoor P.C. Indoor unit room temp.
  • Page 49 Installation Manual Wired Wireless remote controller remote Sensor block display of controller receiving unit Judging Air conditioner display Main defective parts Parts to be checked / error description device status Operation Timer Indication Ready Flashing GR GR OR Indoor fan motor, indoor P.C. Board --- Indoor unit fan error Indoor Indoor AC fan error (fan motor thermal...
  • Page 50 CARRIER AIR CONDITIONING (THAILAND) CO., LTD. 144/9 MOO 5, BANGKADI INDUSTRIAL PARK, TIVANON ROAD, TAMBOL BANGKADI, AMPHUR MUANGPATHUMTHANI, PATHUMTHANI 12000, THAILAND 1130850104 1130850104_EN-FR-ES.indb c2 1130850104_EN-FR-ES.indb c2 4/21/2567 BE 17:30 4/21/2567 BE 17:30...