The information in this document is subject to change without notice. All contents in this document, including statements, information, and recommendations, are believed to be accurate, but they are presented without warranty of any kind, express or implied. H3C shall not be liable for technical or editorial errors or omissions contained herein.
The following information is for generic reference. Plan your installation and removal procedures depending on the actual requirements. The figures in this document are for illustration only. Processor kit The processor kit for a UniServer B5700 G6 server includes the following components: • Processor •...
Page 5
Figure 1 Removing the server Remove the access panel. a. As shown by callout 1 in Figure 2, press the release button on the access panel and slide the access panel a little towards the rear. b. As shown by callout 2 in Figure 2, hold the two sides of the access panel and lift it away from the server.
Installing the processor Guidelines • To avoid damage to the processors or system board, only H3C-authorized personnel and professional server engineers are allowed to install a processor. • Make sure the processors are the same model if two processors are installed.
Figure 4 Processor locations Procedure CAUTION: When you remove the protective cover over the heatsink, be careful not to touch the thermal grease on the heatsink. As shown by callout 1 in Figure 5, tilt the processor to interlock the guide slot at one end of the processor with the guide post at one end of the retaining bracket.
Page 8
Installing a retaining bracket that carries a processor to a heatsink Remove the plastic box on the heatsink. As shown in Figure 6, lift the plastic box to remove it from the heatsink. NOTE: When removing the plastic box, be careful not to touch the thermal grease on the heatsink. Figure 6 Removing the plastic box from a heatsink Install the retaining bracket that carries the processor onto the heatsink.
Page 9
Remove the processor blank from the processor socket in the blade server CAUTION: • The pins in the processor socket are extremely fragile and easily damaged. To avoid replacing the system board due to pin damage, do not touch the pins. •...
Figure 9 Installing the heatsink with the processor onto the blade server Installing DIMMs After you install a new processor, install DIMMs for it. For DIMM installation when two processors are present, see the user guide for the server. To install a DIMM: Open the retaining clips of the DIMM slot.
Starting the server Install the removed air baffles. Install the access panel. Install the server in the rack. Connect power cords for the server. Power on the server.