  • Page 1 INSTALLATION AND OPERATING INSTRUCTIONS MATCH-Angle flange LWR50L-29-00001-A DDOC02345 THE KNOW-HOW FACTORY www.zimmer-group.com...
  • Page 2: Table Of Contents

    13 RoHS declaration ..................................13 14 REACH declaration ..................................13 15 Declaration of Incorporation ..............................14 16 Declaration of Conformity ................................. 15 Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 3: Supporting Documents

    This category contains useful tips for handling the product efficiently. Failure to observe these tips will not result in damage to the product. This information does not include any information relevant to health or workplace safety. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 4: Safety Notices

    • Use of the product under extreme conditions, such as aggressive fluids or abrasive dusts • Additional drilled holes or threads Ö Zimmer GmbH shall accept no liability for any damage caused by improper use. The operator bears sole responsibility.
  • Page 5: Proper Use

    ► Operate the product only when it is in a technical condition that corresponds to the guaranteed parameters and operating conditions. Ö Zimmer GmbH shall accept no liability for any damage caused by improper use. The operator bears sole responsibility.
  • Page 6: Product Description

    Electrical and pneumatic lines are mounted in the angle flange that lead to the outer connections and can be used for the energy supply to the selected grippers. The product has the hot plug function, which enables coupling or decoupling while electrified. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 7: Technical Data

    8 Accessories/scope of delivery INFORMATION If any accessories not sold or authorized by Zimmer GmbH are used, the function of the product cannot be guaranteed. Zimmer GmbH accessories are specifically tailored to the individual products. ► For optional accessories and those included in the scope of delivery, refer to our website.
  • Page 8: Installation

    ► Position the adapter plate on the product with the straight pin. ► Install the adapter plate by using the mounting screws. Straight pins Adapter plate Mounting screw Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 9: Coupling The Stationary Part And Loose Part

    ► Lower the stationary part. Ö The loose part automatically locks with the stationary part during automatic extending out of the storage station. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 10: Installing The Energy Supply

    ► Connect the gripper and the angle flange to pneumatic hoses. ► Install the gripper plugs in the connecting sockets. Connecting socket Pneumatic connection Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 11: Pin Assignment

    ► Before installing an accessory, make sure it is suitable for use with the selected variant. ► You can find information on our website. ► Please contact Customer Service if you have any questions. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 12: Maintenance

    ► Disconnect the product completely from the power supply. ► Dispose of the components properly according to the material groups. ► Comply with the locally applicable environmental and disposal regulations. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 13: Rohs Declaration

    Rheinau, Germany, 2024-10-25 Authorized representative for the (Place and date of issuance) Martin Zimmer compilation of relevant technical (Legally binding signature) documents Managing Partner Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 14: Declaration Of Incorporation

    Rheinau, Germany, 2024-10-25 Authorized representative for the (Place and date of issuance) Martin Zimmer compilation of relevant technical (Legally binding signature) documents Managing Partner Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 15: Declaration Of Conformity

    Rheinau, Germany, 2024-10-25 Authorized representative for the (Place and date of issuance) Martin Zimmer compilation of relevant technical (Legally binding signature) documents Managing Partner Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...

Table of Contents