INTERFACE CONNECTIONS
① Insert the SFP module into the SFP slot.
② Insert the Cat5/6 cable into the RJ45 port.
③ Insert the fibre patch cable into the SFP
module.
Important Note:
Both the RJ45 and SFP ports must be
connected before either port will link.
Both ports must be operating at the same
speed either 1Gb or 10Gb. It is not possible
to mix speeds between ports.
PORT SPEEDS
Example part code:
AMG250-1XBT-1XS-P90
Character
RJ45 Port Speed
F
10/100 Base-T(X)
G
10/100/1000 Base-T(X)
X
1/10G Base-T(X)
*SFP's supplied separately. Refer to AMG website and SFP Datasheets for available models.
POE CAPABILITIES
Example part code:
AMG250-1XBT-1XS-P90
Characters
PoE Standard Supported
None
Non-PoE Model
AT
IEEE 802.3at 30W Port
BT
IEEE 802.3bt 60/90W Port
Check the product label to determine the PoE power supported
on each port and the units total maximum PoE budget.
AMG Systems Ltd. 4 Pioneer Way, Castleford, WF10 5QU, UK T: +44 (0) 1767 600 777 E: technical@amgsystems.com
AMG Systems Inc. 62 Spring Hill Road, Trumbull, CT 06611, USA T: +1-855-AMGPOE1 (855-264-7631)
D33856-00
SFP* Port Speed
100/1000 Base-FX
1/10G Base-R FX
Ensure the PSU size
used is at least equal
to the maximum PoE
budget figure.
IEEE 802.3at Models
Characters
PoE Budget
Type 1 & 2 PoE support
P30
30W Max
Mode A PSE only
P60
60W Max
IEEE 802.3bt Models
P90
90W Max
Type 1, 2, 3 & 4 PoE
support. Mode A
and/or Mode B PSE
www.amgsystems.com
Industrial 10G Media Converter
Industrial 10G Media Converter
amgsystems.com
AMG250 Series
AMG250 Series
Installation Manual - Hardware
Installation Manual - Hardware

Advertisement

loading
Need help?

Need help?

Do you have a question about the AMG250 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for AMG AMG250 Series

  • Page 1 Mode B PSE on each port and the units total maximum PoE budget. AMG Systems Ltd. 4 Pioneer Way, Castleford, WF10 5QU, UK T: +44 (0) 1767 600 777 E: technical@amgsystems.com amgsystems.com AMG Systems Inc. 62 Spring Hill Road, Trumbull, CT 06611, USA T: +1-855-AMGPOE1 (855-264-7631) D33856-00 www.amgsystems.com...
  • Page 2 DIN RAIL MOUNT INSTALLATION SURFACE MOUNT INSTALLATION IP RATING ① Remove the DIN rail clip by unscrewing the two fixing screws as shown. ② Attach the included wall To maintain the units IP40 rating any mount brackets with the screw holes that are not used should still ③...