All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, by anyone other than an authorized Safety-Kleen Service Representative, or employee, without prior written permission of Safety-Kleen Systems, Inc..
Safety-Kleen Systems, Inc. Models 90/90.5/94 and Models 2387/2388 HPM Operator Booklet AFETY EASURES Safety in the workplace is dependent upon the proper use of this unit and the cleaning solution used in it. Therefore, it is important to carefully follow all safe-use instructions and operational procedures provided in this booklet, as well as all instructions included in the cleaning solution’s Safety Data Sheet (SDS) and on the unit labels.
The Model 90 is fabricated with stainless steel; the Models 90.5 and 94 are carbon steel with plastic sink inserts. The Model 90’s sink is the largest of the three; Models 90.5 and 94 include smaller sinks. Each model’s sink sits atop a drum filled with aqueous cleaning solution.
Safety-Kleen Systems, Inc. Models 90/90.5/94 and Models 2387/2388 HPM Operator Booklet XPLODED IEWS ODEL Sink Assembly Lid Knob Fusible Link Standpipe Crumb Cup Filter Screen J-Hook Fusible Link Assembly Not Applicable Lid Hinge Hose & Brush Assembly Lock Nut Sock Filter...
Safety-Kleen Systems, Inc. Models 90/90.5/94 and Models 2387/2388 HPM Operator Booklet 90.5 ODEL Sink Liner Crumb Cup Fusible Link Wing Nut Lid Knob Fusible Link Bracket Fusible Link Hardware Lamp Assembly Sock Filter Half Moon Sink Lid Pump Hose Hose and Brush Assembly...
Use ONLY the cleaning solution provided such as ARMAKLEEN™ 4 in 1 Cleaner or other aqueous cleaning solutions offered by Safety-Kleen Systems. Do not spray aerosols into or around this equipment. Do not add any other cleaning solutions or chemicals to the cleaning solution. The use of other chemicals may cause a hazardous condition.
DO NOT INTERFERE WITH LID CLOSURE IN THE EVENT OF A FIRE. The Model 90 utilizes the J-Hook fusible link standpipe assembly, while the Models 90.5 and 94 have an updated fusible link assembly with a bracket replacing the standpipe.
Page 12
5. Open the lid and position the J-Hook around the standpipe to secure the lid in an open position. Bracket Fusible Link / Model 90.5 / Model 94 1. Align the four holes on the fusible link bracket with the holes located on the rear middle sink edge.
Safety-Kleen Systems, Inc. Models 90/90.5/94 and Models 2387/2388 HPM Operator Booklet PERATION Warning: The HPM control box contains electrical circuits that could electrocute and should only be opened by a qualified technician. Model 2387 HPM Control Box LED fault light...
Page 14
10. When all parts cleaning operations are complete, close the sink lid and set all control box power switches to “OFF”. Models 90.5 and 94 Hose and Brush Assembly 3-way Valve to Control the Flow of Cleaning Solution Nozzle “ON” position All “ON”...
Safety-Kleen Systems, Inc. Models 90/90.5/94 and Models 2387/2388 HPM Operator Booklet Models 90.5 and 94 Hose and Brush Assembly 3-way Valve to Control the Flow of Cleaning Solution Nozzle “ON” position All “ON” position Brush “ON” position ROUBLESHOOTING Check the power cord connection.
Safety-Kleen equipment be your primary contact with Safety-Kleen put the name and phone number of the nearest Safety-Kleen branch on the equipment and/or on the inside cover of this booklet provide information about your service contract with Safety-Kleen ...
Page 17
Safety-Kleen Systems, Inc. 42 Longwater Drive Norwell, MA 02061-9149 Printed in USA Rev. 2020/11 SK 817282...