Page 1
Modular Walk In Installation & Maintenance Instructions 10.23...
Page 2
We will resolve defects free of charge by repairing / replacing parts as we feel necessary. To be free of charge, service work must be carried out by Lakes Bathrooms or approved agents.
Page 3
It is strongly recommended that TWO PERSONS carry out installation! Setting Out: Ensure tray / base is completely Tools Required: level and all tray/base to wall edges are sealed prior to installation. DO NOT BEGIN INSTALLATION ON A TRAY WHICH IS NOT LEVEL &...
Page 4
Wall Mounted Panel Fitting: 1. Ensure 2x rubber buffers are affixed in wall profile before proceeding. Offer wall profile up to wall, ensure plumb and mark 3x screw hole positions. Remove wall profile, drill marked positions with 6mm tile or masonry bit & fit wall plugs. Ensuring wall profile is plumb, fix to wall using 3x screws.
Page 5
90° Corners: End Panel to Front Panel: Front Panel to Fixed Bypass: Fixed Bypass Front Front Panel Panel Panel Corner Bracket Corner Seal fitting (CNR*SEAL) Corner bracket type. (CNR***) Seal may be wetted to ease fitting. Clamp Screw screws cover Glass gaskets 1.
Page 6
4. Gently tighten clamp screws (x2) & press fit cover. Corner Post type. (CP***) Corner Top Cap Corner Post Ensure post grooves & glass edges are clean and free of debris. 1. Apply a continuous bead of silicone sealant the full length of both channels in the corner profile.
Page 7
Hinged Bypass Panel Fitting (profile type). (BY8** / BY10**) Ensure fixed glass edge, & profile groove are clean & free of debris. 1. Apply a continuous bead of silicone sealant the full length of the channel in the hinged bypass profile. 2.
Page 8
Hinged Bypass Panel Fitting (patch hinge type). (PH***) (PHL** / PHR**) Gasket Set - 8mm & 10mm versions 4 x Screw Cover Bottom Bypass Bottom Panel Main Hinge Panel Bypass Glass & Seal Top & Bottom Hinge (PHG***) 2. Carefully insert bypass glass into 1.
Page 9
4. Starting at bottom hinge, fit vertical hinge seal (loop 3. Peel backing strips, align & stick screw covers to the inside (wet) side of enclosure). Seal may be into recesses on hinges (2 top & 2 bottom). wetted to ease fitting. Sealing.
Page 10
In the unlikely event of an enclosure leak, water will be visible on the outside of the enclosure itself, or around the perimeter silicone seal ONLY. Water / moisture appearing outside this area (ie at floor level) is normally due to incorrect tray installation. Lakes Bathrooms Ltd Service : Northern Ireland Ian A Kernohan Alexandra Way...
Need help?
Do you have a question about the Modular Walk In and is the answer not in the manual?
Questions and answers