Page 5
ELETTROQUADRI S.r.l. declines all liability for improper use of the board and for damages caused as a result of operations not considered in this manual or in any case unreasonable.
Page 6
3. CHAPTER of the Installation Manual section - NUMBER and NAME 4. Type of manual 5. Board model and manual revision index 6. Number corresponding to the current page and total number of pages in the whole manual 7. Manufacturer's name and copyright 6 / 28 MP2 - rev. 1.1...
Page 7
1.2.3. General definitions Some recurring terms in the manual are described to ensure a more complete understanding of their meaning. ELETTROQUADRI S.r.l., the manufacturer of the aforementioned board, will be referred to as the Manufacturer. Danger zone: any area inside and/or near the electric cabinet containing the board in which the presence of a person constitutes a risk for the health and safety of said person.
Page 8
1.5. Warranty The MP2 board warranty is valid for 1 year. CAUTION The Manufacturer declines all liability for accidents involving persons or things caused by a failure to observe the instructions and regulations provided in this manual or the non-observance of the safety and accident prevention regulations in force in the country of machine use.
Page 9
Consequently, any intervention which alters board configuration shall automatically exonerate the manufacturer from all liability. Consequently, any use other than those indicated in this manual shall exonerate ELETTROQUADRI S.r.l. from all liability for any risks which may occur. 2.2.2. Warnings for Installer safety Before commencing work, the Installer must be fully knowledgeable of board function, configuration, and technical operating characteristics.
Page 10
(e.g. supervision of installation, testing, adjustments, optimization, etc.). The Manufacturer, if stipulated in the contract with the user, may in any case guarantee, if needed, expert technical intervention via the after-sales assistance service. 10 / 28 MP2 - rev. 1.1...
Page 11
SAFETY FOOTWEAR MUST BE WORN PROTECTIVE GLOVES MUST BE WORN PROTECTIVE CLOTHING MUST BE WORN 2.4. Correct use The MP2 board may ONLY be used in electrical lift control cabinetsELETTROQUADRI S.r.l.. 2.5. Incorrect use The board MUST NOT be used: •...
Page 13
This is a generic manual, consequently, to proceed with installation always refer to the specifications and wiring diagram of the actual system. This is an appendix to the MP2 manual to which reference must be made for everything not concerning the "serial connection".
Page 15
Programming USER, MAINTENANCE AND INSTALLATION MANUAL PROGRAMMING 4.1. General warnings INSTALLER CAUTION During operations the operator must wear all the necessary Personal Protective Equipment (PPE). RESIDUAL RISK OF ELECTROCUTION Risk of electrocution relating to all parts which remain live when the cabinet is opened. IMPORTANT The Manufacturer declines all liability for operations performed: •...
Page 16
Programming USER, MAINTENANCE AND INSTALLATION MANUAL 4.2. Board technical specifications 4.2.1. MP2 base board There are three versions: MP2 - R This is the motherboard, located in the control cabinet, responsible for serial communications, via inputs J3/2-3, with the “car and floor serial boards”.
Page 17
Programming USER, MAINTENANCE AND INSTALLATION MANUAL 4.3. LEDs on CABSER board J22/1 input presence signal Front operator opening limit switch check J22/2 input presence signal Front operator closure limit switch check J22/3 input presence signal Front operator safety edge check (NC) J22/4 input presence signal Rear operator opening limit switch check J22/5 input presence signal...
Page 18
Programming USER, MAINTENANCE AND INSTALLATION MANUAL 4.5. Terminal blocks and connectors 4.5.1. Inputs / outputs on CABSER basic board I = Input U = Output Connector J20 (Numbering from right to left) I – 1 SER+ Serial line + I – 2 SER- Serial line - I –...
Page 19
Programming USER, MAINTENANCE AND INSTALLATION MANUAL Connector J27 (Numbering from left to right) I – 1 CDU/CDD common U – 2 Ascent direction signalling command U – 3 Descent direction signalling command U – 4 Car button press audible confirmation U –...
Page 20
Programming USER, MAINTENANCE AND INSTALLATION MANUAL Connector M13 (Numbering from left to right) U – 7 P6 / A Car position (decimal code) / 7 segments U – 8 P7 / B Car position (decimal code) / 7 segments U – 9 P8 / C Car position (decimal code) / 7 segments U –...
Page 21
Programming USER, MAINTENANCE AND INSTALLATION MANUAL Connector M1 (Numbering from left to right) I/U – 1 Car call/reserve I/U – 2 Car call/reserve I/U – 3 Car call/reserve I/U – 4 Car call/reserve I/U – 5 Car call/reserve I/U – 6 Car call/reserve I/U –...
Page 22
Programming USER, MAINTENANCE AND INSTALLATION MANUAL Connector J7 (Numbering from left to right) I/U – 1 + 24 I/U – 2 U – 3 "Going down" signal I – 4 Not used Connector J8 (Numbering from left to right) I/U – 1 + 24 I/U –...
Page 23
USER, MAINTENANCE AND INSTALLATION MANUAL 4.6. How to Address FLSER Floor Cards In order for it to be recognized and identified by the MP2 motherboard, each FLSER serial board must be “coded” by positioning the DIP switches according to the following table:...
Page 24
Programming USER, MAINTENANCE AND INSTALLATION MANUAL DIP-SWITCHES “1” “2” “3” “4” “5” “6” Control panel n° 37 Control panel n° 38 Control panel n° 39 Control panel n° 40 Control panel n° 41 Control panel n° 42 Control panel n° 43 Control panel n°...
Page 25
(R) Recoverable faults: the lift is still operative and restarts with next call. • (NR) Non recoverable faults: the lift goes out of order and the MP2 board must be reset; the error is deleted in case of power failure, (faults Er - 23/25/27 are kept in memory).
Page 26
Diagnostics USER, MAINTENANCE AND INSTALLATION MANUAL PAGE LEFT INTENTIONALLY BLANK 26 / 28 MP2 - rev. 1.1...
Page 27
It is assumed, for the safe use of the board, that the reader of this chapter is already familiar with the contents of heading 2.2 "Safety Warnings". INSTALLER 6.2. CABSER board lay-out IMPORTANT The layout below is subject to change without prior notice from the manufacturer. 27 / 28 MP2 - rev. 1.1...
Need help?
Do you have a question about the MP2 and is the answer not in the manual?
Questions and answers