Page 1
ELETTROQUADRI SINCE 1983 USER, MAINTENANCE AND INSTALLATION MANUAL MICROPROCESSOR SYSTEM TRANSLATION OF THE ORIGINAL INSTRUCTIONS ENGLISH 2023 - rev. 1.2...
Page 2
REASON FOR REVISION DATE OF REVISION Updated text 18/04/2023 ELETTROQUADRI S.r.l. All rights reserved. This document may not be reproduced or disclosed even in part in any way. Any viola on is punishable by law. Subject to modifi ca on.
Page 3
4.1. General warnings ........................17 4.2. Programming unit (REMP2 remote terminal) ................18 4.2.1. REMP2 programmer display ......................19 4.3. Programming the MP3 board ....................20 4.3.1. How to make a call from the control panel ................. 20 4.4. Further REMP2 programmer func ons ..................32 4.4.1.
Page 4
6.6.3. Serial boards in the car and at the fl oor landings ............... 48 6.6.4. ACF board ............................ 48 6.7. MP3 board lay-out ........................49 6.7.1. LED on MP3 board ........................49 6.8. MPCAB board lay-out ......................50 6.8.1. LEDs on MPCAB board ........................ 50 6.9.
ELETTROQUADRI S.r.l. declines all liability for improper use of the board and for damages caused as a result of opera ons not considered in this manual or in any case unreasonable.
Page 6
3. CHAPTER of the Installa on Manual sec on - NUMBER and NAME 4. Type of manual 5. Board model and manual revision index 6. Number corresponding to the current page and total number of pages in the whole manual 7. Manufacturer's name and copyright 6 / 56 MP3 rev. 1.2...
Page 7
1.2.3. G Some recurring terms in the manual are described to ensure a more complete understanding of their meaning. ELETTROQUADRI S.r.l., the manufacturer of the aforemen oned board, will be referred to as the Manufacturer. Danger zone: any area inside and/or near the electric cabinet containing the board in which the presence of a person cons tutes a risk for the health and safety of said person.
Page 8
INSTALLATION, USE AND MAINTENANCE MANUAL SINCE 1983 Maintenance personnel: Person responsible for servicing and repairing the board. REMP2 remote terminal: External programming device which connects to the MP3 or MPCAB boards. 1.3. M ELETTROQUADRI S.r.l. Via Puccini, 1 21050 Bisuschio (VA) - Italy Tel.
Page 9
Consequently, any interven on which alters board confi gura on shall automa cally exonerate the manufacturer from all liability. Consequently, any use other than those indicated in this manual shall exonerate ELETTROQUADRI S.r.l. from all liability for any risks which may occur.
Page 10
The Manufacturer, if s pulated in the contract with the user, may in any case guarantee, if needed, expert technical interven on via the a er-sales assistance service. 10 / 56 MP3 rev. 1.2...
Page 11
SAFETY FOOTWEAR MUST BE WORN PROTECTIVE GLOVES MUST BE WORN PROTECTIVE CLOTHING MUST BE WORN 2.4. C The MP3 board may ONLY be used in electrical li control cabinets ELETTROQUADRI S.r.l.. 2.5. I The board MUST NOT be used: •...
Page 12
ELETTROQUADRI INSTALLATION, USE AND MAINTENANCE MANUAL SINCE 1983 PAGE LEFT INTENTIONALLY BLANK 12 / 56 MP3 rev. 1.2...
For RM mini-contactor excita on. NORMAL INSPECTION • To bypass the safety chain contacts. N.B.: some terminals are op onal, if they are not present go to the next terminal. • Op onal : 24 VDC bi-stable. 13 / 56 MP3 rev. 1.2...
Page 14
For moving the car down. NORMAL NORMAL INSPECTION DOWN IMPORTANT For the response to the up/down control, refer to “Inspec on control”. CAUTION Before pu ng into opera on remove all jumpers previously wired. 14 / 56 MP3 rev. 1.2...
Page 15
The run of the car is limited by CRS and CRD mechanical switches or by bistable CRSB / CRDB switches at the top and bo om fl oors. • Once the inspec on is completed, the car, if it has been moved, resets to the lowest fl oor, or to its former des na on. 15 / 56 MP3 rev. 1.2...
Page 16
“Con nuous reset” (i.e. with stop and restart) can be set with parameter t0 (see par. 4.4. “Programming the MP3 board”) by entering the car speed (in m/s), posi oning the DM slowdown strip at the bo om fl oor (length 30 cm), and adjus ng parameter P6 to delay ac va on (if necessary).
Page 17
IMPORTANT Before performing any procedure make sure you have read and understood all the various steps, seen all the rela ve images and adopted the safety and protec on measures described. 17 / 56 MP3 rev. 1.2...
Page 18
ELETTROQUADRI USER, MAINTENANCE AND INSTALLATION MANUAL SINCE 1983 4.2. P (REMP2 The REMP2 remote terminal is an external programmer which connects to the MP3 board (connector J4) or MPCAB board (connector J4). PROGR ENT/RST Select the op ons in Select an item and confi rm the selected op ons by moving the item.
Page 19
Floor posi on indicator (e.g. “-1”). Combina on of le ers and numbers for programming the board, mers and other variables and func ons. See par. “4.4. PROGRAMMING THE MP3 BOARD”. Error message. See par. “5.2. FAULT TABLE AND FAULT FINDING”.
Page 20
Press UP and DW together, the display will start fl ashing (and display the lowest fl oor). Select the fl oor you wish to call with UP and DW. Press ENT/RST to confi rm and make the call. 20 / 56 MP3 rev. 1.2...
Page 21
Pressed bu on Condi on Pressed bu on condi on The successive Pb submenu will display To confi rm: ENT/RST ENT/RST → → To go to the next func on in the AL submenu: PROGR → 21 / 56 MP3 rev. 1.2...
Page 22
fl oor. RISB. universal Type of manoeuvre collec ve down car: universal Floors: reserve in order of call fl oors: universal Car: reserved car: reserve. Floors: collec ve complete 22 / 56 MP3 rev. 1.2...
Page 23
fi re services fi re services manoeuvre selec on manoeuvre EN81 (EU regulatory) fi re services manoeuvre ASME (USA regulatory) fi re services manoeuvre EN81- fi re services manoeuvre EN81- 04-07 not u lised 23 / 56 MP3 rev. 1.2...
Page 24
0 to 30 dsec door open delay a er re ring cam drops 1 to 90 simplex: return to main fl oor me (x10) 1 to 90 hydraulic: return to lowest fl oor me 24 / 56 MP3 rev. 1.2...
Page 25
(parameter to = dsec rese ng mode selec on) 0 to 250 A3 hydraulic: valve excita on me during lowest fl oor test if = 0 the test does not run 25 / 56 MP3 rev. 1.2...
Page 26
(with dot on) Emergency manoeuvre actua on by board delay mer min. (with dot off ) 0 to 20 sec. (with dot on) Emergency manoeuvre by board maximum dura on mer min. (with dot off ) 26 / 56 MP3 rev. 1.2...
Page 27
(to close: DCB or wait for fl oor me to me out) disabled (the car parks at the set fl oors) duplo/duplex/triplex/quadruplex opera on: force parking at main fl oor enabled (car returns to main fl oor) 27 / 56 MP3 rev. 1.2...
Page 28
fl oor doors motorized disabled brake control with FLFRN board ac ve disabled enable opera on with code (keypad or RFID) ac ve disabled enable energy saving func on ac ve 28 / 56 MP3 rev. 1.2...
Page 29
UM+DM ac ve (without supplementary reed switches) • with two accesses: emergency stop with UM+DM, door selec no with SEB (DRA) (UM+DM = open side A; UM+DM+SEB = open side B) 29 / 56 MP3 rev. 1.2...
Page 30
fl oor display off set direc on arrows ac ve car display direc on arrows direc on arrows not ac ve direc on arrows fl oor display direc on arrows next direc on arrows 30 / 56 MP3 rev. 1.2...
Page 31
fl oor (default) arriving at car out of service occupied (default) with universal manoeuvre: J6 light opera on occupied fl ashing present arriving at fl oor arriving at car out of service 31 / 56 MP3 rev. 1.2...
Page 32
3. once the limit of 50 is reached, the process terminates; 4. to deac vate it at any me, hold ENT/RST down for at least 10 sec. 4.4.3. E C SELECTION IMPORTANT See the test manual. 4.4.4. I IMPORTANT See the test manual. 32 / 56 MP3 rev. 1.2...
Page 33
ELETTROQUADRI USER, MAINTENANCE AND INSTALLATION MANUAL SINCE 1983 PAGE LEFT INTENTIONALLY BLANK 33 / 56 MP3 rev. 1.2...
Page 34
(R) Recoverable faults: the li is s ll opera ve and restarts with next call. • (NR) Non recoverable faults: the li goes out of order and the MP3 board must be reset; the error is deleted in case of power failure, (faults Er - 25/25/27 are kept in memory).
Page 35
No opening of the door closure limit switch. • With the operator power and running disconnect the door closure contact from input J11/3 (DRA, led IC) or, if double access, contact J11/4 (DRB, led ID). 35 / 56 MP3 rev. 1.2...
Page 36
Er-13 Stopped away from fl oor When the car arrives at the fl oor inputs UM (M2A/2) and DM (M2A/3 ) are missing on the board. Rope, 1 or 2 speeds: the car resets. 36 / 56 MP3 rev. 1.2...
Page 37
Via reed switches UM / DM, the board detects high speed travel between consecu ve fl oors of more than 45 seconds ( me adjustable up to 60 seconds in parameter t0). Hydraulic: the car goes to the lowest fl oor. Rope: the car remains where it is. 37 / 56 MP3 rev. 1.2...
Page 38
Signal to input J7/6 (D2, led D2) lacking, but signal to input J7/4 (D1, led D1) present: the overtravel contact has opened. Hydraulic: the car goes to the lowest fl oor. Rope: the car remains where it is. 38 / 56 MP3 rev. 1.2...
Page 39
During reset, when the up or down signal is sent, the board does not have 24 VDC at J11/1 (FSC, led IA) a er two/four a empts, or does not receive 24 VDC at J11/2 (UD, led IB). 39 / 56 MP3 rev. 1.2...
Page 40
Er-31 (NR) Opera on test of the separate opening of the 2nd valve failed During tes ng at the lowest fl oor with the doors closed, the system releveled when the 2nd valve opened. 40 / 56 MP3 rev. 1.2...
Page 41
Call ELETTROQUADRI S.r.l. Er-65 (NR) Posi on and speed of car via the MP-ENC board • Check the Mpenc board Er-66 (NR) Posi on and speed of car via the MP-ENC board = not ac ve 41 / 56 MP3 rev. 1.2...
Page 42
With the car at the fl oor, it a empts to relevel every 60 s in both direc ons (yo-yo eff ect) at most 10 mes. Verify: • Magne c strip posi on. • Releveling frequency/speed. • Oil leak. Er-84 (NR) Error: doors locked due to too many errors 42 / 56 MP3 rev. 1.2...
Page 43
The set speed threshold. • Slowdown spaces. Er-A4 (NR) CRS1 error with MP-ENC board Er-A5 (NR) CRD1 error with MP-ENC board Er-A6 (NR) CRS2 error with MP-ENC board Er-A7 (NR) CRD2 error with MP-ENC board 43 / 56 MP3 rev. 1.2...
Page 44
Rese able ONLY when the system Is in inspec on mode Er-E6 (NR) RIDB STAYS CLOSED WITH CAR AT LOWEST FLOOR (bistable lowest fl oor inspec on ramp down switch) Rese able ONLY when the system Is in inspec on mode 44 / 56 MP3 rev. 1.2...
Page 45
The control signals for exci ng the drive contactors are output by connector J8 on board MP3, while the red leds light up on the REMP2, depending on the type of actua on:...
Page 46
Further informa ons on the procedure are stated on the control panel specifi c wiring diagram. 6.4. S The MP3 board checks the safety chain status through 4 pick-up points iden fi ed by 4 LEDs on REMP2: Pick-up no.
Page 47
/ mobile pit MPCAB • photocells / safety edges • door operators (op onal) and their limit switches • gong / overload signal IMPORTANT The maximum number of available stops is 32 47 / 56 MP3 rev. 1.2...
Page 48
Phase sampling (it transforms the mains voltage into two low voltage signals sent to terminals J2/2 and J2/3 used by the board to monitor the phases). 6 Amperes For Simplex systems with more than 12 stops and Duplex / Triplex / Quadruplex systems 48 / 56 MP3 rev. 1.2...
Page 49
6.7.1. LED Indica on Descrip on output/ and Input board/program ac ve indica on M2A/2 UM reed switch: up travel M2A/3 DM reed switch: down travel OVLD M2B/3 overload / overtemperature in the machine room 49 / 56 MP3 rev. 1.2...
Page 50
/ side B NC J22/3 rear operator mobile rib / side A NC J22/2 front operator closure limit switch / side A NC J22/1 front operator opening limit switch / side A NC 50 / 56 MP3 rev. 1.2...
Page 51
/ Side B NC J26/3 front door closure command / side A J26/1 front door opening / side A board / program ac ve indica on serial communica ons serial communica ons 6.9. FLSER 6.10. FLDISP 51 / 56 MP3 rev. 1.2...
Page 53
DM reed switch: down travel J11/7 DMS reed switch: up travel minimum distance J11/8 DMD reed switch: down travel minimum distance J21/1 mobile pit / 1 passenger present in car J21/2 no stop (80%) 53 / 56 MP3 rev. 1.2...
Page 54
DPXT board and the presence of the +24D terminal (fl oor reserva on common). IMPORTANT Manual The tests are detailed in Par. 7 "System Tests" in the for the system in ques on. 54 / 56 MP3 rev. 1.2...