  • Page 1 ELETTROQUADRI SINCE 1983 USER, MAINTENANCE AND INSTALLATION MANUAL MICROPROCESSOR SYSTEM TRANSLATION OF THE ORIGINAL INSTRUCTIONS ENGLISH 2023 - rev. 2.9...
  • Page 2 REVISION INDEX REASON FOR REVISION DATE OF REVISION Updated text 18/04/2023...
  • Page 3 4  P ....................17 4.1. General warnings ........................17 4.2. Programming the board ......................17 4.2.1. MP2 board dip switches ......................18 4.2.2. Board display ..........................18 4.3. Programming the MP2 board ....................20 4.4. Further board func ons ......................32 4.4.1. LE selection - Fault log reading....................32 4.4.2.
  • Page 4 DUPLO connec on board (only with separate “arriving” indica ons for the two cabinets) ....48 TPX connec on diagram ........................48 CABSER/CABEXT board ......................... 48 6.5. MP2 board lay-out ........................49 LED on MP2 board..........................49 6.6. Manoeuvres ...........................51 Single call manoeuvre or collec ve down manoeuvre ................51 Collec ve up/down manoeuvre ......................
  • Page 5: General Information

    ELETTROQUADRI S.r.l. declines all liability for improper use of the board and for damages caused as a result of opera ons not considered in this manual or in any case unreasonable.
  • Page 6 3. CHAPTER of the Installa on Manual sec on - NUMBER and NAME 4. Type of manual 5. Board model and manual revision index 6. Number corresponding to the current page and total number of pages in the whole manual 7. Manufacturer's name and copyright 6 / 54 MP2 rev. 2.9...
  • Page 7 1.2.3. G Some recurring terms in the manual are described to ensure a more complete understanding of their meaning. ELETTROQUADRI S.r.l., the manufacturer of the aforemen oned board, will be referred to as the Manufacturer. Danger zone: any area inside and/or near the electric cabinet containing the board in which the presence of a person cons tutes a risk for the health and safety of said person.
  • Page 8 1.5. W The MP2 board warranty is valid for 1 year. CAUTION The Manufacturer declines all liability for accidents involving persons or things caused by a failure to observe the instruc ons and regula ons provided in this manual or the non-observance of the safety and accident preven on regula ons in force in the country of machine use.
  • Page 9 Consequently, any interven on which alters board confi gura on shall automa cally exonerate the manufacturer from all liability. Consequently, any use other than those indicated in this manual shall exonerate ELETTROQUADRI S.r.l. from all liability for any risks which may occur.
  • Page 10 The Manufacturer, if s pulated in the contract with the user, may in any case guarantee, if needed, expert technical interven on via the a er-sales assistance service. 10 / 54 MP2 rev. 2.9...
  • Page 11 SAFETY FOOTWEAR MUST BE WORN PROTECTIVE GLOVES MUST BE WORN PROTECTIVE CLOTHING MUST BE WORN 2.4. C The MP2 board may ONLY be used in electrical li control cabinetsELETTROQUADRI S.r.l.. 2.5. I The board MUST NOT be used: • for any uses other than those described in heading 2.4 "Correct use".
  • Page 12 ELETTROQUADRI INSTALLATION, USE AND MAINTENANCE MANUAL SINCE 1983 PAGE LEFT INTENTIONALLY BLANK 12 / 54 MP2 rev. 2.9...
  • Page 13: Installation

    For RM mini-contactor excita on. NORMAL INSPECTION • To bypass the safety chain contacts. N.B.: some terminals are op onal, if they are not present go to the next terminal. • Op onal : 24 VDC bi-stable. 13 / 54 MP2 rev. 2.9...
  • Page 14 • For moving the car down. NORMAL INSPECTION DOWN IMPORTANT For the response to the up/down control, refer to “Inspec on control”. CAUTION Before pu ng into opera on remove all jumpers previously wired. 14 / 54 MP2 rev. 2.9...
  • Page 15 H6 = Inspec on from panel + pit H7 = Inspec on from pit + car top + panel H FLASHING = pit control panel inspec on ac va on memory: reset MP2 microprocessor board with RST key. 15 / 54...
  • Page 16 “Con nuous reset” (i.e. with stop and restart) can be set with parameter t0 (see par. 4.5. “Programming the MP2 board”) by entering the car speed (in m/s), posi oning the DM slowdown strip at the bo om fl oor (length 30 cm), and adjus ng parameter P6 to delay ac va on (if necessary).
  • Page 17 ELETTROQUADRI USER, MAINTENANCE AND INSTALLATION MANUAL SINCE 1983 PROGRAMMING 4.1. G INSTALLER CAUTION During opera ons the operator must wear all the necessary Personal Protec ve Equipment (PPE). RESIDUAL RISK OF ELECTROCUTION Risk of electrocu on rela ng to all parts which remain live when the cabinet is opened.
  • Page 18 Floor posi on indicator (e.g. “-1”). Combina on of le ers and numbers for programming the board, mers and other variables and func ons. See par. “4.5. PROGRAMMING THE MP2 BOARD”. Error message. See par. “5.2. FAULT TABLE AND FAULT FINDING”.
  • Page 19 ELETTROQUADRI USER, MAINTENANCE AND INSTALLATION MANUAL SINCE 1983 Indica on on the display Descrip on Programming mode Pb → AC: • rear access only. Programming mode Pb → AC: • both accesses. Programming mode PS: • duplo/duplex/triplex/quadruplex: fl oors not served.
  • Page 20 ELETTROQUADRI USER, MAINTENANCE AND INSTALLATION MANUAL SINCE 1983 4.3. P Use the following keys to program the board: PROGR, ENT/RST. There are three ways to access it: • a er opening the automa c valve VA (always present in the electrical cabinet);...
  • Page 21 ELETTROQUADRI USER, MAINTENANCE AND INSTALLATION MANUAL SINCE 1983 MAIN MENU Codes Values Meaning Descrip on Basic programming Programming menu PROGR elements Time programming Op on programming Light signal programming read fault log (see par. 4.5.1) special procedures omnibus opera on (see par. 4.5.2) travel limit test (see par.
  • Page 22 ELETTROQUADRI USER, MAINTENANCE AND INSTALLATION MANUAL SINCE 1983 IMPORTANT The display will show the code of the selected menu and the submenu code (if any) in alterna on. Example of naviga on Possible ini al Pressed bu on Condi on...
  • Page 23 ELETTROQUADRI USER, MAINTENANCE AND INSTALLATION MANUAL SINCE 1983 IMPORTANT The following tables illustrate the complete programming structure, but some op ons may no longer display a er certain func ons have been set. Basic programming ENT/RST Codes Values Meaning Descrip on...
  • Page 24 ELETTROQUADRI USER, MAINTENANCE AND INSTALLATION MANUAL SINCE 1983 PP to UP -- = PP duplo/duplex/triplex/quadruplex: alterna ve parking fl oor 0 to UP duplo/duplex/triplex/quadruplex: fl oors not served (skip fl oors) front rear P.S. front+rear parking doors open parking doors...
  • Page 25 ELETTROQUADRI USER, MAINTENANCE AND INSTALLATION MANUAL SINCE 1983 Timer programming ENT/RST Code range unit of default meaning and use measurement 50 to 250 duplo/duplex/triplex/quadruplex: closest call func on ac va on me 0 to 250 only if Ele roquadri has set “PICK-UP manoeuvre”: main fl oor...
  • Page 26 U03* 0 to 50 emergency manoeuvre maximum dura on mer * IMPORTANT With MP2/NR or MP2/ND boards. A ".” a er the fi rst digit indicates SECONDS. No "." a er the fi rst digit indicates MINUTES. 26 / 54...
  • Page 27 ELETTROQUADRI USER, MAINTENANCE AND INSTALLATION MANUAL SINCE 1983 Op on programming ENT/RST Codes Values Meaning Descrip on does not monitor phase control monitors front self-retaining in door closure rear A.c. front+rear front self-retaining in door opening rear A.o. front+rear disabled...
  • Page 28 ELETTROQUADRI USER, MAINTENANCE AND INSTALLATION MANUAL SINCE 1983 Op on programming ENT/RST Codes Values Meaning Descrip on disabled: car call bu on actua on, closes fl oor me meout (door closure) the doors and resets fl oor me enabled: doors close on car call disabled (to close: DCB or wait for fl...
  • Page 29 ELETTROQUADRI USER, MAINTENANCE AND INSTALLATION MANUAL SINCE 1983 Op on programming ENT/RST Codes Values Meaning Descrip on disabled block second a empt to open with fl oor bu on ac ve in slowdown gong opera on on stop G.o. on doors opening...
  • Page 30 ELETTROQUADRI USER, MAINTENANCE AND INSTALLATION MANUAL SINCE 1983 Op on programming ENT/RST Codes Values Meaning Descrip on disabled If ac ve: • with one access: emergency stop with UM+DM (without supplementary reed switches) ac ve • with two accesses: emergency stop with UM+DM, door selec no with SEB (DRA) (UM+DM = open side A;...
  • Page 31 ELETTROQUADRI USER, MAINTENANCE AND INSTALLATION MANUAL SINCE 1983 Display and lights programming ENT/RST Codes Values Meaning Descrip on 1 row per fl oor type of car display (serial only) gray 0 to 7 car display off set absolute gray code, car display...
  • Page 32 ELETTROQUADRI USER, MAINTENANCE AND INSTALLATION MANUAL SINCE 1983 4.4. F 4.4.1. LE SELECTION Hold down PROGR un l LE displays, then press ENT/RST. The displays reads: 1. If no errors are memorized, the display indicates 0E; 2. the display shows the fi rst saved error with the indica on “Er+number” (see chapter 5 Diagnos cs);...
  • Page 33 (R) Recoverable faults: the li is s ll opera ve and restarts with next call. • (NR) Non recoverable faults: the li goes out of order and the MP2 board must be reset; the error is deleted in case of power failure, (faults Er - 23/25/27 are kept in memory).
  • Page 34 No opening of the door closure limit switch. • With the operator power and running disconnect the door closure contact from input J11/3 (DRA, led IC) or, if double access, contact J11/4 (DRB, led ID). 34 / 54 MP2 rev. 2.9...
  • Page 35 Er-13 Stopped away from fl oor When the car arrives at the fl oor inputs UM (M2A/2) and DM (M2A/3 ) are missing on the board. Rope, 1 or 2 speeds: the car resets. 35 / 54 MP2 rev. 2.9...
  • Page 36 Via reed switches UM / DM, the board detects high speed travel between consecu ve fl oors of more than 45 seconds ( me adjustable up to 60 seconds in parameter t0). Hydraulic: the car goes to the lowest fl oor. Rope: the car remains where it is. 36 / 54 MP2 rev. 2.9...
  • Page 37 Signal to input J7/6 (D2, led D2) lacking, but signal to input J7/4 (D1, led D1) present: the overtravel contact has opened. Hydraulic: the car goes to the lowest fl oor. Rope: the car remains where it is. 37 / 54 MP2 rev. 2.9...
  • Page 38 ▪ 24 VDC at terminals RZA/RZB (via the respec ve reed switches) and excita on of the corresponding minirelays. ▪ Check the safety circuit. • Defec ve board (if repor ng an error with the signal present). 38 / 54 MP2 rev. 2.9...
  • Page 39 During tes ng at the lowest fl oor with the doors closed, the system releveled when the 1st valve opened. Verify: • Opera on of the 2nd valve. Er-31 (NR) Rope: movement detected while tes ng prove clamp “FB” (clamp “A” does not hold) 39 / 54 MP2 rev. 2.9...
  • Page 40 The board verifi es the presence of the EQ-HAD board. Verify: • Board connec ons Er-67 When the front doors are opened, monitoring of the front door auxiliary contact opening The board verifi es the lack of input J21/6 (CF3, led CF3). 40 / 54 MP2 rev. 2.9...
  • Page 41 See error Er-07. Er-85 (NR) Fire services fault Check the fault on the variable frequency drive Er-86 (NR) Jumpers on car door contacts The board verifi es the presence of input J7/8 (D3, led D3). 41 / 54 MP2 rev. 2.9...
  • Page 42 CRSB MALFUNCTION (bistable ramp down control and top fl oor rese ng switch) Rese able ONLY when the system Is in inspec on mode Er-E4 (NR) RIDB MALFUNCTION (bistable lowest fl oor inspec on ramp down switch) 42 / 54 MP2 rev. 2.9...
  • Page 43 Rese able ONLY when the system Is in inspec on mode Er-E6 (NR) RIDB STAYS CLOSED WITH CAR AT LOWEST FLOOR (bistable lowest fl oor inspec on ramp down switch) Rese able ONLY when the system Is in inspec on mode 43 / 54 MP2 rev. 2.9...
  • Page 44 ELETTROQUADRI USER, MAINTENANCE AND INSTALLATION MANUAL SINCE 1983 PAGE LEFT INTENTIONALLY BLANK 44 / 54 MP2 rev. 2.9...
  • Page 45 INSTALLER 6.2. I IMPORTANT During electrical insula on test all sockets must be removed from MP2 board and from its expansions. Further informa ons on the procedure are stated on the control panel specifi c wiring diagram. 6.3. S UM/DM reed With only two contacts (UM / DM), in combina on with four magne c strips per fl...
  • Page 46 This is the motherboard, located in the control cabinet, responsible for serial communica ons, via inputs J3/2-3, with the "car serial boards". Exis ng in the following versions: MP2 – R/S Universal Max 12 stops Simplex collec ve down Max 12 stops MP2 –...
  • Page 47 PUC - 5 With 6 mini-relays per display with the “Gray” or “binary” logic PUC - 13 With 13 mini-relays per display with the “7 segment/a,b,c,d..” logic IMPORTANT Floor indica on from -9 to 32. 47 / 54 MP2 rev. 2.9...
  • Page 48 Two versions exis ng: DUPLO - For connec on with a 20 pole cable to the MP2 board DUPLO - For connec on with a 16 pole cable to the EXP expansion boards TPX connection diagram Installs in a Triplex in cabinet B or in a Quadruplex in cabinets B and C to simplify and facilitate connec on of external calls between the cabinets using fl...
  • Page 49 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 MANOEUVRE LED on MP2 board Indica on Descrip on o u t p u t /...
  • Page 50 J12/5 Programmable input J12/6 Programmable input J12/2 Programmable input J12/3 Programmable input M2B/3 open doors bu on M2B/4 close doors bu on M2B/5 reserve car manoeuvre J12/1 fi re services manoeuvre 50 / 54 MP2 rev. 2.9...
  • Page 51 • Duplo - universal manoeuvre with interdic on of simultaneous call between two li s • Duplo - universal manoeuvre with interdic on of simultaneous call between two li s and arrival of the nearest car Diff erent or special manoeuvres can be implemented on request. 51 / 54 MP2 rev. 2.9...
  • Page 52 MP2-D board and the presence of terminal +24D (fl oor reserve common). They can be recognised and diff er only in the diff erent posi ons of dip switches 6, 7 and 8 on the MP2-D board:...