Summary of Contents for Euresys PC3629

  • Page 1 HANDBOOK eGrabber Coaxlink Converter Handbook PC3629 Coaxlink CXP-12 to QSFP+ Converter © EURESYS S.A. 2024 - Doc. D219ET-Coaxlink Converter Handbook-eGrabber-24.12.1.2193 built on 2024-12-17...
  • Page 2 This documentation is provided with eGrabber 24.12.1 (doc build 2193). www.euresys.com This documentation is subject to the General Terms and Conditions stated on the website of EURESYS S.A. and available on the webpage https://www.euresys.com/en/Menu-Legal/Terms-conditions. The article 10 (Limitations of Liability and Disclaimers) and article 12 (Intellectual Property Rights) are more specifically...
  • Page 3 3. CoaXPress-over-Fiber Device Interface 3.1. CoaXPress-over-Fiber Interface Specifications 3.2. CoaXPress-over-Fiber PART III : HARDWARE MANUAL 1. Mechanical Specification 1.1. PC3629 Coaxlink CXP-12 to QSFP+ Converter 1.2. Connectors CoaXPress Micro-BNC 4 Connector CoaXPress-over-Fiber QSFP+ Connector 24 V DC Power Input 1.3. LEDs and Switches...
  • Page 4 eGrabber Coaxlink Converter Handbook 4.3. DC Power Output PART IV : GENAPI FEATURES 1. Coaxlink Converter 1.1. Root Category DeviceControl ConverterControl ImageFormatControl AcquisitionControl TransportLayerControl DeviceDetails 1.2. DeviceControl Category DeviceType DeviceScanType DeviceVendorName DeviceModelName DeviceManufacturerInfo DeviceProductCode DeviceSerialNumber DevicePartNumber DeviceUserID DeviceVersion DeviceFirmwareVersion DeviceFirmwareVariant ExpectedXMLVersion XMLVersion XMLFirstRelease...
  • Page 5 eGrabber Coaxlink Converter Handbook Height PixelFormat TestPatternSelector 1.5. AcquisitionControl Category AcquisitionMode AcquisitionStart AcquisitionStop 1.6. TransportLayerControl Category PayloadSize CoaXPress TLParamsLocked 1.7. CoaXPress Category CxpLinkConfigurationPreferred CxpLinkConfiguration CxpConnectionSelector CxpTestMode CxpConnectionTestErrorCount CxpConnectionTestPacketCount CxpConnectionTestPacketCountTx 1.8. DeviceDetails Category FlacVersion PreviousBootBank NextBootBank CurrentBankSelect NextBankSelect PotBankStatus NextBootRevision...
  • Page 6 eGrabber Coaxlink Converter Handbook PART I GETTING STARTED...
  • Page 7 1.1. Installation Box content Quantity Item PC3629 Coaxlink CXP-12 to QSFP+ Converter 2-pin 5.08mm pitch terminal plug 3629 Coaxlink CXP-12 to QSFP+ Converter Installation Guide Mounting The out-of-the box product is ready for a desktop or a wall-mount usage. The enclosure is fitted...
  • Page 8 eGrabber Coaxlink Converter Handbook PART I Getting Started 1.2. Connectors Location and Markings CoaXPress QSFP+ POWER STATUS POWER Input Output 24 V DC 1.3. Connections Power input Connect a 24V DC power supply to the POWER IN connector via a 2-pin 5.08 mm pitch terminal plug: Turn off or disconnect the power source before proceeding Connect the GND to the GND input (pin 2) of the 2-pin terminal plug...
  • Page 9 Configure the converter After booting, the converter is in "Maintenance mode" where all converter-specific parameters are accessible from the GenAPI Remote Device Module. In "Maintenance mode" , the PC3629 Coaxlink CXP-12 to QSFP+ Converter allows configuring the converter parameters. Configure the converter parameters according to your needs.
  • Page 10 eGrabber Coaxlink Converter Handbook PART II FUNCTIONAL GUIDE...
  • Page 11 Coaxlink Converter Handbook PART II Functional Guide 1. Converter Modes State Diagram PC3629 Coaxlink CXP-12 to QSFP+ Converter state diagram The converter has two operation modes, respectively named Maintenance mode and Converter mode . Maintenance mode In Maintenance mode , the converter supports the CoF Device discovery.  It appears as a regular...
  • Page 12 Advanced features with Euresys frame grabber When the converter is connected to the Euresys PC3625 Coaxlink QSFP+ frame grabber, a subset of the Converter GenApi features is exposed in its GenTL Interface XML file:...
  • Page 13 eGrabber Coaxlink Converter Handbook PART II Functional Guide Loss of CoaXPress-over-Fiber ● Trip on any PoCXP overcurrent protection (OCP) ● Enforce the Maintenance mode* ● * Only when connected to a PC3625 Coaxlink QSFP+...
  • Page 14 2.3. CoaXPress LED Lamps 2.4. CoaXPress LED lamps mode control 2.5. Power Over CoaXPress 2.6. Connection Test 2.1. CoaXPress Host Interface Specifications Functional specifications summary of the CoaXPress camera interface of PC3629 Coaxlink CXP- 12 to QSFP+ Converter Connectivity requirements Property Value...
  • Page 15 Image stream format Rectangular image - Line-scan Scanning Progressive-scan 2.2. Host Connections Maps The Host Interface of PC3629 Coaxlink CXP-12 to QSFP+ Converter supports the following connection mappings 1D4 host connections map One 1- or 2- or 4-connection device Connection 0...
  • Page 16 eGrabber Coaxlink Converter Handbook PART II Functional Guide 3D211 host connections map One 1- or 2-connection and one or two 1-connection devices Connection 0 Connection 0 Connection 1 Device 0 Connection 0 Device 1 Connection 0 Device 2 4D1111 host connections map One or two or three or four 1-connection devices Connection 0 Device 0...
  • Page 17 3629 This table describes the states of the CoaXPress LED lamps mounted on the front panel of PC3629 Coaxlink CXP-12 to QSFP+ Converter. The last column shows the availability of a state: All modes: the state is available with both...
  • Page 18 0.5 Hz color 2, 1 second off) NOTE The Euresys frame grabbers provides the capability to control the lamps. Refer to "CoaXPress LED lamps mode control" on page 19 In case of multiple errors, there shall be at least two green Flash_12_5 pulses before the next error is indicated...
  • Page 19 eGrabber Coaxlink Converter Handbook PART II Functional Guide 2.4. CoaXPress LED lamps mode control LampMode feature of the Interface module defines the lamps operation mode: When set to Standard (default value), the lamps indicate the state of the CoaXPress Link ●...
  • Page 20 JPEG, PC3620-4 Coaxlink Quad CXP-12 JPEG, PC3621 Coaxlink Mono CXP-12, PC3621-LH Coaxlink Mono CXP-12 LH, PC3622 Coaxlink Duo CXP-12, PC3622-LH Coaxlink Duo CXP-12 LH, PC3623 Coaxlink Quad CXP-12 Value, PC3624 Coaxlink Quad CXP-12 DF, PC3633 Coaxlink Quad CXP-12 3D-LLE and PC3629 Coaxlink CXP-12 to QSFP+ Converter.
  • Page 21 eGrabber Coaxlink Converter Handbook PART II Functional Guide Automatic PoCXP control command the PTU controller initiates a PoCXP device On execution of the CxpPoCxpAuto detection procedure . NOTE Since version 3.1 of the driver, the automatic PoCXP is enabled at system power-up! The application is not anymore required to enable PoCXP powering by issuing a CxpPoCxpAuto...
  • Page 22 eGrabber Coaxlink Converter Handbook PART II Functional Guide PoCXP detection mode control CxpPoCxpDetectionMode feature of the Interface module selects either the standard or the extended (default) power over CoaXPress detection mode. When set to Extended, the PoCXP device detection of Coaxlink cards is configured for an extended range of resistance values.
  • Page 23 eGrabber Coaxlink Converter Handbook PART II Functional Guide 2.6. Connection Test The CoaXPress Host Interface provides connection test facilities to test the quality up- and down-connections of the CoaXPress link according to the procedures defined in section 8.7 of the CoaXPress 1.1 standard. For each individual CoaXPress connector, it implements A test generator ●...
  • Page 24 eGrabber Coaxlink Converter Handbook PART II Functional Guide 3. CoaXPress-over-Fiber Device Interface 3.1. CoaXPress-over-Fiber Interface Specifications 3.2. CoaXPress-over-Fiber...
  • Page 25 Coaxlink Converter Handbook PART II Functional Guide 3.1. CoaXPress-over-Fiber Interface Specifications Functional specifications summary of the CoaXPress-over-Fiber interface of PC3629 Coaxlink CXP-12 to QSFP+ Converter Connectivity requirements Property Value Standard CoaXPress-over-Fiber (Device) Physical medium QSFP+ Link speed CoF-10 Link width...
  • Page 26 There is no "power over fiber". As signals in fiber optics are transmitted using light, there is ● no way to transfer power over fiber optics and devices such as cameras must be powered separately. PC3625 Coaxlink QSFP+ and PC3629 Coaxlink CXP-12 to QSFP+ Converter.
  • Page 27 eGrabber Coaxlink Converter Handbook PART II Functional Guide What are the cable options for CoaXPress-over-Fiber? One of the most important benefits of CoaXPress-over-Fiber is the wide variety of connectivity options already available from multiple companies. The initial connectivity options for CoaXPress-over-Fiber and the PC3625 Coaxlink QSFP+ at 10 Gbps are SFP+ and QSFP+ (Quad, or four times SFP+) modules.
  • Page 28 eGrabber Coaxlink Converter Handbook PART II Functional Guide What are the jitter and latency of CoaXPress-over-Fiber? How do they compare to "traditional" CoaXPress? CoaXPress-over-Fiber is based on the CoaXPress protocol and it exhibits the same high performance as CoaXPress in terms of jitter and latency. In addition, as CoaXPress-over-Fiber supports higher transmission speed compared to CoaXPress, the jitter and latency will be further improved in these versions.
  • Page 29 eGrabber Coaxlink Converter Handbook PART III HARDWARE MANUAL...
  • Page 30 Manual 1. Mechanical Specification Mechanical specifications of the product(s) including: product pictures, physical dimensions, connectors description and pin assignments, LEDs description, switches description, etc. 1.1. PC3629 Coaxlink CXP-12 to QSFP+ Converter 1.2. Connectors 1.3. LEDs and Switches 1.4. Physical Characteristics...
  • Page 31 Coaxlink Converter Handbook PART III Hardware Manual 1.1. PC3629 Coaxlink CXP-12 to QSFP+ Converter Product pictures Connectors and LED's From left to right on front panel: ● "CoaXPress LED Lamps" on page 39 CoaXPress ● "CoaXPress Micro-BNC 4 Connector" on page 34...
  • Page 32 eGrabber Coaxlink Converter Handbook PART III Hardware Manual Mounting...
  • Page 33 eGrabber Coaxlink Converter Handbook PART III Hardware Manual 1.2. Connectors CoaXPress Micro-BNC 4 Connector CoaXPress-over-Fiber QSFP+ Connector 24 V DC Power Input...
  • Page 34 Signal Usage Inner1 CXP_A CoaXPress Host Connection A Outer1 Ground Inner2 CXP_B CoaXPress Host Connection B Outer2 Ground Inner3 CXP_C CoaXPress Host Connection C Outer3 Ground Inner4 CXP_D CoaXPress Host Connection D Outer4 Ground PC3629 Coaxlink CXP-12 to QSFP+ Converter.
  • Page 35 Transmitter D inverted data Tx4p Transmitter D non-inverted data Ground ModSel Module select Reset Module reset Vcc-Rx +3.3 V receiver power supply Two-wire serial interface clock Two-wire serial interface data Ground Rx3p Receiver C non-inverted data PC3629 Coaxlink CXP-12 to QSFP+ Converter.
  • Page 36 eGrabber Coaxlink Converter Handbook PART III Hardware Manual Signal Usage Rx3n Receiver C inverted data Ground Rx1p Receiver A non-inverted data Rx1n Receiver A inverted data Ground Ground Rx2n Receiver B inverted data Rx2p Receiver B non-inverted data Ground Rx4n Receiver D inverted data Rx4p Receiver D non-inverted data...
  • Page 37 Value Name, Label POWER Type 2-pin 5.08mm pitch terminal socket Location Rear panel Usage 24 V DC power input Pin assignments For 3629 CXP to CoF adapter Signal Usage +24 V Power input Ground PC3629 Coaxlink CXP-12 to QSFP+ Converter.
  • Page 38 eGrabber Coaxlink Converter Handbook PART III Hardware Manual 1.3. LEDs and Switches CoaXPress LED Lamps CoaXPress-over-Fiber LED Lamps Status LED Power LED...
  • Page 39 3629 This table describes the states of the CoaXPress LED lamps mounted on the front panel of PC3629 Coaxlink CXP-12 to QSFP+ Converter. The last column shows the availability of a state: All modes: the state is available with both...
  • Page 40 0.5 Hz color 2, 1 second off) NOTE The Euresys frame grabbers provides the capability to control the lamps. Refer to "CoaXPress LED lamps mode control" on page 19 In case of multiple errors, there shall be at least two green Flash_12_5 pulses before the next error is indicated...
  • Page 41 Duty Cycle Flash_1 1 Hz 20% (200 milliseconds on, 800 milliseconds off) NOTE The Euresys frame grabbers provides the capability to control the lamps. Refer to "CoaXPress LED lamps mode control" on page 19 PC3629 Coaxlink CXP-12 to QSFP+ Converter.
  • Page 42 eGrabber Coaxlink Converter Handbook PART III Hardware Manual Status LED Applies to: 3629 Status LED indicator states Symbol Meaning state No power. The device is not powered. FPGA NOK. The FPGA start-up procedure is not completed. Device status OK. Solid The main power distribution network is operational and the FPGA green start-up procedure has successfully completed.
  • Page 43 eGrabber Coaxlink Converter Handbook PART III Hardware Manual Power LED Applies to: 3629 Power LED indicator states Symbol Meaning state No power. The device is not powered. Solid Power OK. green The main power distribution network is operational. Power NOK. Possible causes are: There is no power delivered on the +24 V power input ●...
  • Page 44 1.4. Physical Characteristics Weight Product Gross weight Net weight PC3629 Coaxlink CXP-12 to QSFP+ Converter 930 g 32.80 oz 776 g 27.37 oz PC1676 AC-DC Power Adapter, 24V, 160W 701 g 24.73 oz 654 g 23.07 oz Dimensions Product Dimensions...
  • Page 45 eGrabber Coaxlink Converter Handbook PART III Hardware Manual 2. Electrical Specification Electrical specification of the product(s) including: electrical characteristics of all the input/output ports, description of the power distribution, power requirements, etc. 2.1. CoaXPress CXP-12 Host Interface 2.2. CoaXPress CoF-10 Device Interface 2.3.
  • Page 46 Coaxlink Quad CXP-12 JPEG, PC3621 Coaxlink Mono CXP-12, PC3621-LH Coaxlink Mono CXP-12 LH, PC3622 Coaxlink Duo CXP-12, PC3622-LH Coaxlink Duo CXP-12 LH, PC3623 Coaxlink Quad CXP-12 Value, PC3624 Coaxlink Quad CXP-12 DF, PC3633 Coaxlink Quad CXP-12 3D-LLE and PC3629 Coaxlink CXP-12 to QSFP+ Converter.
  • Page 47 eGrabber Coaxlink Converter Handbook PART III Hardware Manual PTU - Power transmitting unit specification Parameter Min. Typ. Max. Unit DC output voltage Available output power OCP holding current OCP nominal trip current Device detection sense resistance kΩ The Power Transmitting Unit provides 24 V DC power, over-current protection (OCP) and PoCXP device detection as specified by the CoaXPress Standard.
  • Page 48 It fulfills the electrical requirements of the SNIA SFF-8436 specification for QSFP+ 4X 10 Gb/s Pluggable Transceiver modules See also: "CoaXPress-over-Fiber QSFP+ Connector" on page 35 PC3629 Coaxlink CXP-12 to QSFP+ Converter. Identical to the effective receiver data rate of CXP-12...
  • Page 49 eGrabber Coaxlink Converter Handbook PART III Hardware Manual 2.3. Power Distribution Schemes...
  • Page 50 Coaxlink card above the operating temperature range is prohibited since it may induce unexpected PTC trips. "CoaXPress LED Lamps" on page 39 reflect the state of each CoaXPress host connection. See also: Power Over CoaXPress in the Functional Guide PC3629 Coaxlink CXP-12 to QSFP+ Converter.
  • Page 51 eGrabber Coaxlink Converter Handbook PART III Hardware Manual 3. Environmental Specification Environmental specification of the product(s) including: climatic requirements, electromagnetic standards compliance statements, safety standards compliance statements, etc. 3.1. Storage Conditions 3.2. Operating Conditions 3.3. Thermal Design Data 3.4. Compliance Statements...
  • Page 52 Coaxlink Quad CXP-12 JPEG, PC3620-4 Coaxlink Quad CXP-12 JPEG, PC3621 Coaxlink Mono CXP-12, PC3621-LH Coaxlink Mono CXP-12 LH, PC3622 Coaxlink Duo CXP-12, PC3622-LH Coaxlink Duo CXP-12 LH, PC3623 Coaxlink Quad CXP-12 Value, PC3624 Coaxlink Quad CXP-12 DF, PC3625 Coaxlink QSFP+, PC3633 Coaxlink Quad CXP-12 3D-LLE and PC3629 Coaxlink CXP-12 to QSFP+ Converter.
  • Page 53 The thermal design of the surrounding environment must ensure that, at ● any time, the FPGA die temperature never exceeds the recommended limit. Exceeding the upper limit of the FPGA die temperature can permanently ● damage the card. PC1628 Grablink Duo and PC3629 Coaxlink CXP-12 to QSFP+ Converter.
  • Page 54 12, PC3603-4 Coaxlink Quad CXP-12, PC3620 Coaxlink Quad CXP-12 JPEG, PC3620-4 Coaxlink Quad CXP-12 JPEG, PC3621 Coaxlink Mono CXP-12, PC3622 Coaxlink Duo CXP-12, PC3623 Coaxlink Quad CXP-12 Value, PC3624 Coaxlink Quad CXP-12 DF, PC3625 Coaxlink QSFP+, PC3633 Coaxlink Quad CXP-12 3D-LLE and PC3629 Coaxlink CXP-12 to QSFP+ Converter.
  • Page 55 This product has been tested in typical class A compliant host systems. It is assumed that this product will also achieve compliance in any class A compliant unit. To meet EC requirements, shielded cables must be used to connect a peripheral to the product. PC3629 Coaxlink CXP-12 to QSFP+ Converter.
  • Page 56 Connect the equipment into an outlet on a circuit different from that to which the receiver ● is connected. Consult the dealer or an experienced radio/TV technician for help. ● PC1629 Coaxlink Duo PCIe/104-EMB, PC1635 Coaxlink Quad G3 DF, PC3602 Coaxlink Octo and PC3629 Coaxlink CXP- 12 to QSFP+ Converter.
  • Page 57 Duo CXP-12, PC3622-LH Coaxlink Duo CXP-12 LH, PC3623 Coaxlink Quad CXP-12 Value, PC3624 Coaxlink Quad CXP-12 DF, PC3625 Coaxlink QSFP+, PC3629 Coaxlink CXP-12 to QSFP+ Converter, PC1636 InterPC C2C-Link Adapter, PC3610 HD26F I/O Extension Module - TTL-RS422, PC3612 HD26F I/O Extension Module - TTL-CMOS5V-RS422, PC3614 HD26F...
  • Page 58 eGrabber Coaxlink Converter Handbook PART III Hardware Manual 4. Accessories 4.1. PC1676 AC-DC Power Adapter, 24V, 160W 4.2. AC Power Input 4.3. DC Power Output...
  • Page 59 The input connector is a IEC320-C14 standard 3-pole AC inlet. The output is fitted with a 1.2 meter cable terminated with a 2-pin 5.08mm pitch terminal plug compatible with the PC3629 Coaxlink CXP-12 to QSFP+ Converter 24 V DC power input. Connectors ●...
  • Page 60 eGrabber Coaxlink Converter Handbook PART III Hardware Manual 4.2. AC Power Input Applies to 1676 Connector description Property Value Name, Label AC In Type IEC320 C14 male power cord inlet socket Location Power adapter body Usage Universal AC power input Pin assignments PC1676 AC-DC Power Adapter, 24V, 160W.
  • Page 61 eGrabber Coaxlink Converter Handbook PART III Hardware Manual 4.3. DC Power Output Applies to 1676 Connector description Property Value Name, Label DC Out Type 2-pin 5.08mm pitch terminal plug Location 1.2 m power adapter cable Usage 24 V DC power output Pin assignments For 1676 power adapter Signal...
  • Page 62 eGrabber Coaxlink Converter Handbook PART IV GenApi Features PART IV GENAPI FEATURES...
  • Page 63 eGrabber Coaxlink Converter Handbook PART IV GenApi Features 1. Coaxlink Converter Categorized features list of Remote Device module version 24_12_0 1.1. Root Category 1.2. DeviceControl Category 1.3. ConverterControl Category 1.4. ImageFormatControl Category 1.5. AcquisitionControl Category 1.6. TransportLayerControl Category 1.7. CoaXPress Category 1.8.
  • Page 64 eGrabber Coaxlink Converter Handbook PART IV GenApi Features 1.1. Root Category DeviceControl ConverterControl ImageFormatControl AcquisitionControl TransportLayerControl DeviceDetails...
  • Page 65 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceControl Feature Info Module Category Path Type Access Remote Device Root Category Imposed: RO Short Description Category for device information and control. Category Members See also: "DeviceControl Category" on page 71...
  • Page 66 eGrabber Coaxlink Converter Handbook PART IV GenApi Features ConverterControl Feature Info Module Category Path Type Access Remote Device Root Category Imposed: RO Short Description Category for the converter Control features. Category Members See also: "ConverterControl Category" on page 108...
  • Page 67 eGrabber Coaxlink Converter Handbook PART IV GenApi Features ImageFormatControl Feature Info Module Category Path Type Access Remote Device Root Category Imposed: RO Short Description Category for Image Format Control features. Category Members See also: "ImageFormatControl Category" on page 113...
  • Page 68 eGrabber Coaxlink Converter Handbook PART IV GenApi Features AcquisitionControl Feature Info Module Category Path Type Access Remote Device Root Category Imposed: RO Short Description Category for the acquisition control features. Category Members See also: "AcquisitionControl Category" on page 122...
  • Page 69 eGrabber Coaxlink Converter Handbook PART IV GenApi Features TransportLayerControl Feature Info Module Category Path Type Access Remote Device Root Category Imposed: RO Short Description Category that contains the transport Layer control features. Category Members See also: "TransportLayerControl Category" on page 126...
  • Page 70 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceDetails Feature Info Module Category Path Type Access Remote Device Root Category Imposed: RO Short Description Category gives device boot/flash bank information. Category Members See also: "DeviceDetails Category" on page 138...
  • Page 71 eGrabber Coaxlink Converter Handbook PART IV GenApi Features 1.2. DeviceControl Category DeviceType DeviceScanType DeviceVendorName DeviceModelName DeviceManufacturerInfo DeviceProductCode DeviceSerialNumber DevicePartNumber DeviceUserID DeviceVersion DeviceFirmwareVersion DeviceFirmwareVariant ExpectedXMLVersion XMLVersion XMLFirstRelease FirmwareXmlCompatibility DeviceSFNCVersionMajor DeviceSFNCVersionMinor DeviceSFNCVersionSubMinor DeviceManifestEntrySelector DeviceManifestXMLMajorVersion DeviceManifestXMLMinorVersion DeviceManifestXMLSubMinorVersion DeviceManifestSchemaMajorVersion DeviceManifestSchemaMinorVersion DeviceManifestPrimaryURL DeviceTLType DeviceTLVersionMajor DeviceTLVersionMinor DeviceTLVersionSubMinor DeviceStreamChannelCount DeviceStreamChannelSelector...
  • Page 72 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceStreamChannelType DeviceStreamChannelEndianness DeviceStreamChannelPacketSize...
  • Page 73 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceType Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Enumeration Imposed: RO Short Description Returns the device type. Enumeration Values Transmitter: Data stream transmitter device. ● Receiver: Data stream receiver device. ●...
  • Page 74 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceScanType Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Enumeration Imposed: RW Short Description Scan type of the sensor of the device. Enumeration Values Areascan: 2D sensor. ● Linescan: 1D sensor.
  • Page 75 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceVendorName Feature Info Module Category Path Type Access Remote Device Root → DeviceControl String Imposed: RO Short Description Name of the manufacturer of the device.
  • Page 76 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceModelName Feature Info Module Category Path Type Access Remote Device Root → DeviceControl String Imposed: RO Short Description Model of the device.
  • Page 77 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceManufacturerInfo Feature Info Module Category Path Type Access Remote Device Root → DeviceControl String Imposed: RO Short Description Manufacturer information about the device.
  • Page 78 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceProductCode Feature Info Module Category Path Type Access Remote Device Root → DeviceControl String Imposed: RO Short Description Device`s product code. This string is a unique identifier of the device.
  • Page 79 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceSerialNumber Feature Info Module Category Path Type Access Remote Device Root → DeviceControl String Imposed: RO Short Description Device`s serial number. This string is a unique identifier of the device.
  • Page 80 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DevicePartNumber Feature Info Module Category Path Type Access Remote Device Root → DeviceControl String Imposed: RO Short Description Device`s part number. This string is a unique identifier of the device.
  • Page 81 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceUserID Feature Info Module Category Path Type Access Remote Device Root → DeviceControl String Imposed: RW Short Description User-programmable device identifier.
  • Page 82 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceVersion Feature Info Module Category Path Type Access Remote Device Root → DeviceControl String Imposed: RO Short Description Version of the device.
  • Page 83 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceFirmwareVersion Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Integer Imposed: RO Short Description Version of the firmware in the device.
  • Page 84 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceFirmwareVariant Feature Info Module Category Path Type Access Remote Device Root → DeviceControl String Imposed: RO Short Description Variant of the firmware in the device.
  • Page 85 eGrabber Coaxlink Converter Handbook PART IV GenApi Features ExpectedXMLVersion Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Integer Imposed: RO Short Description First XML version used with this firmware.
  • Page 86 eGrabber Coaxlink Converter Handbook PART IV GenApi Features XMLVersion Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Integer Imposed: RO Short Description Version of the current XML file.
  • Page 87 eGrabber Coaxlink Converter Handbook PART IV GenApi Features XMLFirstRelease Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Integer Imposed: RO Short Description First firmware version using current XML.
  • Page 88 eGrabber Coaxlink Converter Handbook PART IV GenApi Features FirmwareXmlCompatibility Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Enumeration Imposed: RO Short Description Reports compatibility between firmware and XML file Enumeration Values Firmware_XML_match: Firmware and XML match. ●...
  • Page 89 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceSFNCVersionMajor Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Integer Imposed: RO Short Description Major version of the Standard Features Naming Convention that was used to create the device`s GenICam XML.
  • Page 90 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceSFNCVersionMinor Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Integer Imposed: RO Short Description Minor version of the Standard Features Naming Convention that was used to create the device`s GenICam XML.
  • Page 91 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceSFNCVersionSubMinor Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Integer Imposed: RO Short Description Sub minor version of Standard Features Naming Convention that was used to create the device`s GenICam XML.
  • Page 92 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceManifestEntrySelector Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Integer Imposed: RO Short Description Selects the manifest entry to reference. Selected Features ● "DeviceManifestXMLMajorVersion" on page 93 ● "DeviceManifestXMLMinorVersion" on page 94 ●...
  • Page 93 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceManifestXMLMajorVersion Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Integer Imposed: RO Short Description Indicates the major version number of the GenICam XML file of the selected manifest entry.
  • Page 94 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceManifestXMLMinorVersion Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Integer Imposed: RO Short Description Indicates the minor version number of the GenICam XML file of the selected manifest entry.
  • Page 95 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceManifestXMLSubMinorVersion Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Integer Imposed: RO Short Description Indicates the subminor version number of the GenICam XML file of the selected manifest entry.
  • Page 96 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceManifestSchemaMajorVersion Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Integer Imposed: RO Short Description Indicates the major version number of the schema file of the selected manifest entry.
  • Page 97 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceManifestSchemaMinorVersion Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Integer Imposed: RO Short Description Indicates the minor version number of the schema file of the selected manifest entry.
  • Page 98 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceManifestPrimaryURL Feature Info Module Category Path Type Access Remote Device Root → DeviceControl String Imposed: RO Short Description Indicates the first URL to the GenICam XML device description file of the selected manifest entry.
  • Page 99 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceTLType Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Enumeration Imposed: RO Short Description Transport Layer type of the device. Enumeration Values GigEVision: GigE Vision. ● CameraLink: Camera Link. ●...
  • Page 100 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceTLVersionMajor Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Integer Imposed: RO Short Description Major version of the Transport Layer of the device.
  • Page 101 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceTLVersionMinor Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Integer Imposed: RO Short Description Minor version of the Transport Layer of the device.
  • Page 102 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceTLVersionSubMinor Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Integer Imposed: RO Short Description Sub minor version of the Transport Layer of the device.
  • Page 103 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceStreamChannelCount Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Integer Imposed: RO Short Description Indicates the number of streaming channels supported by the device.
  • Page 104 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceStreamChannelSelector Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Integer Imposed: RW Value Info Minimum value: Maximum value: Short Description Selects the stream channel to control. Selected Features ●...
  • Page 105 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceStreamChannelType Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Enumeration Imposed: RO Short Description Reports the type of the stream channel. Enumeration Values Transmitter: Data stream transmitter channel. ●...
  • Page 106 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceStreamChannelEndianness Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Enumeration Imposed: RW Short Description Endianess of multi-byte pixel data for this stream. Enumeration Values Big: Stream channel data is big Endian. ●...
  • Page 107 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceStreamChannelPacketSize Feature Info Module Category Path Type Access Remote Device Root → DeviceControl Integer Imposed: RW Value Info Unit: B Short Description Specifies the stream packet size, in bytes, to send on the selected channel for a Transmitter or specifies the maximum packet size supported by a receiver.
  • Page 108 eGrabber Coaxlink Converter Handbook PART IV GenApi Features 1.3. ConverterControl Category DeviceOperatingMode DeviceReboot DeviceFanRotation DeviceTemperature...
  • Page 109 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceOperatingMode Feature Info Module Category Path Type Access Remote Device Root → ConverterControl Enumeration Imposed: RW Short Description Reports the operating mode. Enumeration Values Maintenance: Maintenance mode. ● Converter: Converter mode. ●...
  • Page 110 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceReboot Feature Info Module Category Path Type Access Remote Device Root → ConverterControl Command Imposed: WO Short Description Reboot device.
  • Page 111 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceFanRotation Feature Info Module Category Path Type Access Remote Device Root → ConverterControl Integer Imposed: RO Short Description Rotation of the fan.
  • Page 112 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceTemperature Feature Info Module Category Path Type Access Remote Device Root → ConverterControl Integer Imposed: RO Short Description Temperature of the board.
  • Page 113 eGrabber Coaxlink Converter Handbook PART IV GenApi Features 1.4. ImageFormatControl Category StreamSelect StreamID DeviceTapGeometry Width Height PixelFormat TestPatternSelector...
  • Page 114 eGrabber Coaxlink Converter Handbook PART IV GenApi Features StreamSelect Feature Info Module Category Path Type Access Remote Device Root → ImageFormatControl Enumeration Imposed: RW Short Description Stream select. Selected Features ● "Width" on page 117 ● "Height" on page 118 ●...
  • Page 115 eGrabber Coaxlink Converter Handbook PART IV GenApi Features StreamID Feature Info Module Category Path Type Access Remote Device Root → ImageFormatControl Integer Imposed: RO Short Description Stream ID of selected stream.
  • Page 116 eGrabber Coaxlink Converter Handbook PART IV GenApi Features DeviceTapGeometry Feature Info Module Category Path Type Access Remote Device Root → ImageFormatControl Enumeration Imposed: RW Short Description This device tap geometry feature describes the geometrical properties characterizing the taps of a camera as presented at the output of the device. Enumeration Values Geometry_1X_1Y: Geometry_1X_1Y ●...
  • Page 117 eGrabber Coaxlink Converter Handbook PART IV GenApi Features Width Feature Info Module Category Path Type Access Remote Device Root → ImageFormatControl Integer Imposed: RW Value Info Minimum value: Maximum value: 16384 Short Description Width of the image provided by the device (in pixels).
  • Page 118 eGrabber Coaxlink Converter Handbook PART IV GenApi Features Height Feature Info Module Category Path Type Access Remote Device Root → ImageFormatControl Integer Imposed: RW Value Info Minimum value: Maximum value: 16384 Short Description Height of the image provided by the device (in pixels).
  • Page 119 eGrabber Coaxlink Converter Handbook PART IV GenApi Features PixelFormat Feature Info Module Category Path Type Access Remote Device Root → ImageFormatControl Enumeration Imposed: RW Short Description Format of the pixels provided by the device. It represents all the information provided by PixelCoding, PixelSize, PixelColorFilter combined in a single feature.
  • Page 120 eGrabber Coaxlink Converter Handbook PART IV GenApi Features BayerGB16: ● BayerBG16: ● RGB8: ● RGB10: ● RGB12: ● RGB14: ● RGB16: ● RGBA8: ● RGBA10: ● RGBA12: ● RGBA14: ● RGBA16: ●...
  • Page 121 eGrabber Coaxlink Converter Handbook PART IV GenApi Features TestPatternSelector Feature Info Module Category Path Type Access Remote Device Root → ImageFormatControl Enumeration Imposed: RW Short Description Selects the type of test pattern that is generated by the device as image source. Enumeration Values GreyHorizontalRampMoving: ●...
  • Page 122 eGrabber Coaxlink Converter Handbook PART IV GenApi Features 1.5. AcquisitionControl Category AcquisitionMode AcquisitionStart AcquisitionStop...
  • Page 123 eGrabber Coaxlink Converter Handbook PART IV GenApi Features AcquisitionMode Feature Info Module Category Path Type Access Remote Device Root → AcquisitionControl Enumeration Imposed: RO Short Description Sets the acquisition mode of the device. It defines mainly the number of frames to capture during an acquisition and the way the acquisition stops.
  • Page 124 eGrabber Coaxlink Converter Handbook PART IV GenApi Features AcquisitionStart Feature Info Module Category Path Type Access Remote Device Root → AcquisitionControl Command Imposed: WO Short Description Starts the Acquisition of the device. The number of frames captured is specified by AcquisitionMode.
  • Page 125 eGrabber Coaxlink Converter Handbook PART IV GenApi Features AcquisitionStop Feature Info Module Category Path Type Access Remote Device Root → AcquisitionControl Command Imposed: WO Short Description Stops the Acquisition of the device at the end of the current Frame. It is mainly used when AcquisitionMode is Continuous but can be used in any acquisition mode.
  • Page 126 eGrabber Coaxlink Converter Handbook PART IV GenApi Features 1.6. TransportLayerControl Category PayloadSize CoaXPress TLParamsLocked...
  • Page 127 eGrabber Coaxlink Converter Handbook PART IV GenApi Features PayloadSize Feature Info Module Category Path Type Access Remote Device Root → TransportLayerControl Integer Imposed: RO Value Info Unit: B Short Description Provides the number of bytes transferred for each image or chunk on the stream channel. This includes any end-of-line, end-of-frame statistics or other stamp data.
  • Page 128 eGrabber Coaxlink Converter Handbook PART IV GenApi Features CoaXPress Feature Info Module Category Path Type Access Remote Device Root → TransportLayerControl Category Imposed: RO Short Description Category that contains the features pertaining to the CoaXPress transport layer of the device. Category Members See also: "CoaXPress Category"...
  • Page 129 eGrabber Coaxlink Converter Handbook PART IV GenApi Features TLParamsLocked Feature Info Module Category Path Type Access Remote Device Root → TransportLayerControl Integer Imposed: RW Short Description Used by the Transport Layer to prevent critical features from changing during acquisition.
  • Page 130 eGrabber Coaxlink Converter Handbook PART IV GenApi Features 1.7. CoaXPress Category CxpLinkConfigurationPreferred CxpLinkConfiguration CxpConnectionSelector CxpTestMode CxpConnectionTestErrorCount CxpConnectionTestPacketCount CxpConnectionTestPacketCountTx...
  • Page 131 eGrabber Coaxlink Converter Handbook PART IV GenApi Features CxpLinkConfigurationPreferred Feature Info Module Category Path Type Access Remote Device Root → TransportLayerControl → CoaXPress Enumeration Imposed: RO Short Description Provides the Link configuration that allows the Transmitter Device to operate in its default mode.
  • Page 132 eGrabber Coaxlink Converter Handbook PART IV GenApi Features CxpLinkConfiguration Feature Info Module Category Path Type Access Remote Device Root → TransportLayerControl → CoaXPress Enumeration Imposed: RW Short Description This feature allows specifying the Link configuration for the communication between the Receiver and Transmitter Device.
  • Page 133 eGrabber Coaxlink Converter Handbook PART IV GenApi Features CxpConnectionSelector Feature Info Module Category Path Type Access Remote Device Root → TransportLayerControl → CoaXPress Integer Imposed: RW Value Info Minimum value: Short Description Selects the CoaXPress physical connection to control. Selected Features ●...
  • Page 134 eGrabber Coaxlink Converter Handbook PART IV GenApi Features CxpTestMode Feature Info Module Category Path Type Access Remote Device Root → TransportLayerControl → CoaXPress Enumeration Imposed: RW Short Description Enables the test mode for all physical connection of the Device. Enumeration Values Off: Off ●...
  • Page 135 eGrabber Coaxlink Converter Handbook PART IV GenApi Features CxpConnectionTestErrorCount Feature Info Module Category Path Type Access Remote Device Root → TransportLayerControl → CoaXPress Integer Imposed: RW Short Description Reports the current connection error count for test packets recieved by the device on the connection selected by CxpConnectionSelector.
  • Page 136 eGrabber Coaxlink Converter Handbook PART IV GenApi Features CxpConnectionTestPacketCount Feature Info Module Category Path Type Access Remote Device Root → TransportLayerControl → CoaXPress Integer Imposed: RW Short Description Reports the current count for test packets recieved by the device on the connection selected by CxpConnectionSelector.
  • Page 137 eGrabber Coaxlink Converter Handbook PART IV GenApi Features CxpConnectionTestPacketCountTx Feature Info Module Category Path Type Access Remote Device Root → TransportLayerControl → CoaXPress Integer Imposed: RW Short Description Reports the current count for test packets recieved by the device on the connection selected by CxpConnectionSelector.
  • Page 138 eGrabber Coaxlink Converter Handbook PART IV GenApi Features 1.8. DeviceDetails Category FlacVersion PreviousBootBank NextBootBank CurrentBankSelect NextBankSelect PotBankStatus NextBootRevision...
  • Page 139 eGrabber Coaxlink Converter Handbook PART IV GenApi Features FlacVersion Feature Info Module Category Path Type Access Remote Device Root → DeviceDetails Integer Imposed: RO Short Description Verison of the FLAC.
  • Page 140 eGrabber Coaxlink Converter Handbook PART IV GenApi Features PreviousBootBank Feature Info Module Category Path Type Access Remote Device Root → DeviceDetails Integer Imposed: RO Short Description Flash bank used during the previous power on.
  • Page 141 eGrabber Coaxlink Converter Handbook PART IV GenApi Features NextBootBank Feature Info Module Category Path Type Access Remote Device Root → DeviceDetails Integer Imposed: RO Short Description Flash bank that will be used during the next power on.
  • Page 142 eGrabber Coaxlink Converter Handbook PART IV GenApi Features CurrentBankSelect Feature Info Module Category Path Type Access Remote Device Root → DeviceDetails Integer Imposed: RO Short Description Current Bank Select.
  • Page 143 eGrabber Coaxlink Converter Handbook PART IV GenApi Features NextBankSelect Feature Info Module Category Path Type Access Remote Device Root → DeviceDetails Integer Imposed: RO Short Description Next Bank Select.
  • Page 144 eGrabber Coaxlink Converter Handbook PART IV GenApi Features PotBankStatus Feature Info Module Category Path Type Access Remote Device Root → DeviceDetails Integer Imposed: RO Short Description Pot Bank Status.
  • Page 145 eGrabber Coaxlink Converter Handbook PART IV GenApi Features NextBootRevision Feature Info Module Category Path Type Access Remote Device Root → DeviceDetails Enumeration Imposed: RW Short Description CoaXPress revision store in rom. Enumeration Values Cxp11: CoaXPress Rev. 1.1 ● Cxp20: CoaXPress Rev. 2.0 ●...