Do not position the equipment in a way that
it would be difficult to reach and operate the
power cable.
If the equipment is used in a manner not
specified by the manufacturer, the safety
protection
of
the
compromised.
Do not replace detachable mains supply cords
with inadequately rated cords.
Always make sure that you are using a safety
grounded socket with a safety grounded
mains supply cord to connect the mains
supply.
Sparklike
Laser Portable
Table of Contents
1.
Sparklike Laser Specifications
2.
Connections
3.
Starting up the Sparklike Laser
4.
Start using the equipment
5.
Taking a measurement
6.
Troubleshooting
7.
Service and maintenance
8.
Technical specifications
equipment
may
be
INSTRUCTION MANUAL
Never flush the device with a gas flow greater
than 3 litres/min (Chapter 5.1.2).
To ensure the measurement accuracy device
must be calibrated annually.
Unauthorized modification or replacement
of components is forbidden. This will void the
warranty and may cause danger to the user.
For maintenance, refer to Sparklike Oy or
Sparklike Service Partners
Sparklike technology since 2000
2.2
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Laser Portable 2.2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for sparklike Laser Portable 2.2

  • Page 1 ▶ Do not replace detachable mains supply cords For maintenance, refer to Sparklike Oy or with inadequately rated cords. Sparklike Service Partners ▶ Always make sure that you are using a safety...
  • Page 2 Connector panel: Connections 3. STARTING UP THE SPARKLIKE LASER After connecting all the cables and turning the main switch on, turn on the device from the power switch on the main unit. A green light will light up after few seconds around the power switch.
  • Page 3 Double glass measurement is set as a default for The following chapters will discuss each page of the Sparklike Laser analyser, this can be observed software – Main Page, Settings Page, and Test Page from the “IG type” indicator. It is possible to –...
  • Page 4 In the middle of the page, the user is able to set values via the drop-down boxes, the software observe the results on the thickness of the identifies the glass and cavities thicknesses in the glass and the space between the glasses as well ±1 mm range from each given value.
  • Page 5 This spaced and between 30-70 points spacing ensures the correct operation of Sparklike Laser. approximately. See test menu picture. To ensure the quality of the measurements it is recommendable that the user checks the oxygen If these are correct, press STOP. The indicator below concentration every two hours.
  • Page 6 ▶ Apply dry and pure (> 99.99%) flushing gas flow of 1–3 l/min (max 3 l/min and 1 bar) to the hose. Sparklike Laser is a gas fill analyser; however, it ▶ Press the “Flushing” button on the software measures the oxygen absorption from the insulating (light on the button will turn on).
  • Page 7 Safe values to edit   Blue light blinking Vacuum missing are, e.g. High_limit and Low_limit for the indicator lights on the Main page of Sparklike  Green Measurement about to end/ Application. It is not recommended to edit done other values without consulting Sparklike product support.
  • Page 8 Main page with results for triple glass Average result on the Settings page 5.5 Factors to consider when measuring consistent but there are exceptional results, Here is a list of factors that might impact the repeat the measurement. The exceptional measuring.
  • Page 9 DAQ card is working. Then shut down windows and after that, restart the device. If this does not solve the problem, contact the product support at Sparklike for instructions. If DAQ led is off, contact the product support at Sparklike for instructions.
  • Page 10 “Laser I&T” test, one can fine-tune the temperature correct, the device is firmly against the glass, and as follows (Sparklike technical support can help the device is not tilted. In these cases, the device with this).
  • Page 11 Settings Page problems ▶ turn the measuring head slowly upside Sparklike Laser is a gas fill analyser that works by down a few times to help remove oxygen measuring the oxygen inside the glazing unit. (otherwise keep the measuring head...
  • Page 12 Here is a list of Error message/User notification and recommended actions. Error message/User notification Recommended actions Options, Settings and/or Calibration file compatibility Check or update the files. error! Calibration will expire soon! Contact “Sparklike.com” Send device to calibration. for calibration. Calibration Expired! Contact “Sparklike.com” for Send device to calibration. calibration.
  • Page 13 TEC NOT ON! Check that the lights are ON in the “Connector panel” located inside the main unit. Restart the device. Contact service@sparklike.com. LASER ON CURRENT LIMIT! Check that the “I_value” in “Settings.ini” file is between 4,3-5,7 and “Laser I&T” test gives the same result as int the “Settings.ini”...
  • Page 14 Go to sparklike. made for delicate optical instruments. com/guidance/lp to get instructions how to pack the device for transportation. With Laser Portable 2.2 you have the option to send The device pack on a pallet...
  • Page 15 Power output Display 12” HD Touch Screen Software Windows 10, Laser Software by Sparklike (all included) Data logging capability SSD Storage (232 GB), USB/Network transfer * Typical construction of the insulating glass unit ** At least 30 measurements are needed that 95 % confidence interval is valid...
  • Page 16 Scan the QR-code for further instructions and support SPARKLIKE OY www.sparklike.com Helsinki, Finland 09/2023...