sparklike Laser Portable 2.0 Instruction Manual
Hide thumbs Also See for Laser Portable 2.0:

Advertisement

Quick Links

Your IG Quality Assurance
NOTIFICATIONS:
Do not position the equipment in a way that it would be
Î
difficult to reach and operate the power cable.
If the equipment is used in a manner not specified by the
Î
manufacturer, the safety protection of the equipment
may be compromised.
Do not replace detachable mains supply cords with
Î
inadequately rated cords.
Always make sure that you are using a safety grounded
Î
socket with a safety grounded mains supply cord to
connect the mains supply.
INSTRUCTION MANUAL
Sparklike
Laser Portable
Table of Contents
1.
Sparklike Laser Specifications
2.
Starting up the Sparklike LASER
3.
Start using the equipment
4.
Taking a measurement
5.
Troubleshooting
6.
Service and maintenance
7.
Connections
8.
Technical specifications
Never flush the device with a gas flow greater than 3 litres/
Î
min (Chapter 3.2).
To ensure the measurement accuracy device must be
Î
calibrated annually.
Unauthorized modification or replacement of components
Î
is forbidden. This will void the warranty and may cause
danger to the user. For maintenance, refer to Sparklike Oy or
Sparklike Service Partners.
Sparklike technology since 2000
2.0

Advertisement

loading
Need help?

Need help?

Do you have a question about the Laser Portable 2.0 and is the answer not in the manual?

Questions and answers

Summary of Contents for sparklike Laser Portable 2.0

  • Page 1 Do not replace detachable mains supply cords with is forbidden. This will void the warranty and may cause Î inadequately rated cords. danger to the user. For maintenance, refer to Sparklike Oy or Sparklike Service Partners. Always make sure that you are using a safety grounded Î...
  • Page 2 Class 1 laser is eye-safe under normal maintenance. operating conditions. 2. STARTING UP THE SPARKLIKE LASER The power switch has an indicator light: After connecting all the cables, turn on the device from the power switch on the main unit. A blue light...
  • Page 3 Double glass measurement is set as a default for following chapter labelled Software - Settings Page). Sparklike Laser analyser, this can be observed from the “Double IG” indicator being green. It is possible to measure also triple glazed products. To...
  • Page 4 3.2.2 User interface – Settings Page “Enable counter” and “Meas. count” (3) refer to settings for making multiple measurements (discussed below in The Settings Page of the software entails the following Section 4.3.1). functions: defining glass and spacer thicknesses (pre- set), setting measurement time, setting the device for “High limit”...
  • Page 5 This ensures “Laser I (mA)” should be 1,7–5,9 mA and “Laser R Î the correct operation of Sparklike Laser. To ensure the (kOhm)” should be 5–17 kOhm). The values are quality of the measurements it is recommendable that...
  • Page 6 Apply dry and pure (> 99.9%) flushing gas flow of 1–3 Î l/min (maximum 3 l/min!) to the hose. Sparklike Laser is a gas fill analyser; however, it meas- ures the oxygen absorption from the insulating glass Press the “Gas fill” button on the software (light on Î...
  • Page 7 Save and close the file stops, and the measuring head is released from the glass. “Ready” led turns green and the results are dis- Stop and restart the Sparklike Application to use played on the Main Page. the new settings values.
  • Page 8 For a double glazed unit, only the “Cavity 1” Check that the glass and cavity dimensions are what Î result is shown. they should be. If they are not, see the troubleshooting section in Chapter 5.8. For a triple glazed unit, all three results are Î...
  • Page 9 Test page “Laser 20 seconds before restarting the device. I&R” test, one can fine-tune the temperature as follows (Sparklike technical support can help you on this). 5.4 Drive error Check from the connector panel that all the circular multipin connectors are firmly attached.
  • Page 10 20 min of flushing time. If the oxygen level settles to a value over 0.1% and does not go any lower, please check Sparklike Laser is a gas fill analyser that works by meas- that: uring the oxygen inside the glazing unit. To ensure cor- rect readings, oxygen needs to be removed from inside the used flushing gas is pure (>99.9 % argon)
  • Page 11 If the problems persist, please contact Î compare the results. If most of the measurements sparklike@sparklike.com. Also, please be prepared to are consistent but there are exceptional results, have the IG structure information, coating characteris- repeat the measurement. The exceptional results tics available, and the measurements data file.
  • Page 12 Please contact Sparklike sparklike@sparklike.com open the remote connection for technical support. 6.3 Packing and shipping Sparklike Laser Portable 2.0 is sensitive measuring device and the device must be packed appropriately to sparklike.com/guidance/lp ensure safe shipping. Go to to get instructions how to pack the device for transpor- tation.
  • Page 13 4x circular multipin connector, RJ-45, 2x USB 2.0, VAC Power (C14) Display 10.1” Touch Screen with Pen Software Windows 10, Laser Software by Sparklike (all included) Data logging capability SSD Storage (15 GB), USB/Network transfer * Typical construction of the insulating glass unit...
  • Page 14 Scan the QR-code for further instructions and support sparklike.com/guidance/lp SPARKLIKE OY www.sparklike.com Hermannin rantatie 12 A 21, 00580 Helsinki, Finland 05/2021...