Page 2
NI-SCOPE instrument driver software. This document applies to the following digitizers: NI 5102, NI 5105, NI 5112, NI 5114, NI 5122, NI 5124, NI 5132, NI 5133, NI 5142, NI 5152, NI 5153, NI 5154, NI 5620, NI 5621, NI 5622, NI 5911, and NI 5922.
Page 3
NI 5152/5153/5154 Front Panels....................20 NI 5622 Front Panels ........................21 Appendix B: Front Panels for Traditional NI-DAQ (Legacy) Devices..........22 NI 5102 Front Panels ........................22 NI 5112 Front Panels ........................25 NI 5620/5621 Front Panels ......................26 NI 5911 Front Panel........................27 Appendix C: Troubleshooting ......................
Page 4
NI LabVIEW SignalExpress CD (USB devices only) Note SMC-based devices are based on the National Instruments Synchronization and Memory Core architecture. These include the NI 5105, NI 5114, NI 5122, NI 5124, NI 5142, NI 5152, NI 5153, NI 5154, NI 5622, and NI 5922. For more information, refer to the NI High-Speed Digitizers Help.
Page 5
Other Required Items In addition to the items contained in the kit, you need the following items: ❑ 1/8 in. flat-head screwdriver ❑ One of the following configurations: – (PXI Devices) A PXI chassis, a PXI/SCXI combination chassis, or a PXI/CompactPCI chassis with a controller and the chassis documentation (PXI Express Devices) –...
Page 7
PXI Chassis Screws NI PXI Module Ejector Handle in Downward Position Figure 1. PXI Module Installation PXI Express Modules Follow the installation instructions in the PXI Modules section and install the module in a PXI Express slot of the chassis. Refer to the chassis documentation for information about the markings that denote PXI Express slots.
Page 9
Secure the device to the PCI chassis with a screw. Caution It is important to completely screw the device front panel into the PCI slot, both for mechanical stability and to create a solid ground connection. Improperly secured devices may affect the accuracy of the device.
Page 11
Mounting the USB-513x You can use the USB-513x on a desktop or mount it to a standard DIN rail or a panel. Desktop Use The USB-513x has plastic guides on the underside that allow it to be stacked on top of other USB-513x devices.
Page 13
Note (USB devices) When you first install an NI USB-5132/5133, Windows will recognize a new device. Click Next on any dialog boxes that appear to complete the installation. After Windows recognizes newly installed device, a dialog box prompts you to select from the following options, which may vary depending on the devices and software installed on your system: •...
Page 15
Soft Front Panel. The NI-SCOPE SFP provides context-sensitive help for its controls. Acquiring Data Programmatically You can use NI-SCOPE to begin programming the digitizer in your ADE. Refer to the Programming section of the NI High-Speed Digitizers Help at Start»All Programs»National Instruments» NI-SCOPE»Documentation. NI-SCOPE Examples ™...
Page 17
NI 5114 Front Panels Figure 11 shows the NI PXI-5114 and NI PCI-5114 front panels. For the AUX connector pinout information, refer to Figure 13. NI PXI-5114 CH 0 CH 0 CH 1 CH 1 TRIG TRIG CLK IN CLK IN AUX I/O +5 V AUX I/O...
Page 19
Table 3. NI 5122/5124/5142/5922 Front Panel Signal Connections (Continued) Connector Description Function CLK OUT Standard SMB jack NI 5122/5124/5142: Output for the reference clock or sample connector clock. NI 5922: Output for the reference clock. AUX I/O 9-pin mini-circular DIN Provides access to the multipurpose digital timing and connector triggering lines, PFI 0, and PFI 1 (with optional cable).
Page 21
NI 5152/5153/5154 Front Panels Figure 16 shows the NI PXI-5152/5153/5154 and NI PCI-5152/5153/5154 front panels. ACCESS ACTIVE CH 0 TRIG TRIG CH 1 PFI 0 PFI 1 PFI0 PFI1 Figure 16. NI 5152/5153/5154 Front Panels Table 5 describes the signal connections for the NI 5152/5153/5154. Table 5.
Page 23
NI-DAQ (Legacy) devices: NI 5102, NI 5112, NI 5620/5621, and NI 5911. NI 5102 Front Panels The NI 5102 is available for PXI and PCI platforms. This section describes the front panels and signal connections for both types of NI 5102 digitizers.
Page 24
9-pin mini-circular DIN Access to PFI 2 (with optional cable). For pinout information, connector refer to Figure 19. Figure 19 shows the pin assignments for the 9-pin DIN connector on the NI PXI-5102. +5 V (Fused) Reserved Reserved Reserved...
Page 25
PFI 2 Standard SMB jack Multipurpose digital timing and triggering signal. connector Note When used as inputs, NI 5102 PFI lines can trigger an acquisition and/or allow an external sample clock connection. NI High-Speed Digitizers Getting Started Guide ni.com...
Page 27
NI 5620/5621 Front Panels Figure 22 shows the NI PXI-5620/5621 front panels. NI PXI-5620 NI PXI-5621 64 MS/s Digitizer 64 MS/s Digitizer INPUT INPUT +20 dBm MAX +20 dBm MAX ±2 VDC MAX ±3 VDC MAX REF CLK IN REF CLK IN +16 dBm MAX +20 dBm MAX ±10 VDC MAX...
Page 29
Appendix C: Troubleshooting Front Panel ACCESS LED on PXI/PXI Express Module is Off when PXI/PXI Express Chassis is On If the ACCESS LED on the digitizer is not lit after you power on the PXI/PXIe chassis, a problem may exist with the PXI/PXIe power rails, a hardware device, or the LED. Note The LEDs may not light until the device has been configured in MAX.
Page 30
If the software optimization application is not installed on your system, use the MXI software CD or the National Instruments Driver CD included with your kit to install the software. After installation, you may need to restart your computer before running the MXI Optimization Application.
Page 31
National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. National Instruments also has offices located around the world to help address your support needs. For telephone support in the United States, create your service request at and follow the calling instructions or dial 512 795 8248.
Page 32
National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or ni.com/patents.
Page 33
スタートアップガイド 高速デジタイザ NI-SCOPE このドキュメントでは、 高速デジタイザの取り付け、構成、テスト、また 計 測器ドライバソフトウェアによるプログラミング方法について説明します。 このドキュメン NI 5102 NI 5105 NI 5112 NI 5114 NI 5122 NI 5124 NI 5132 NI 5133 トは、 、 、 、 、 、 、 、 、 NI 5142 NI 5152 NI 5153 NI 5154...
Page 34
......................20 フロントパネル NI 5152/5153/5154 ..................... 21 フロントパネル NI 5622 ........................22 フロントパネル NI-DAQ ..........23 付録 従来型 (レガシー)用デバイスのフロントパネル NI 5102 ........................23 フロントパネル NI 5112 ........................26 フロントパネル NI 5620/5621 ......................27 フロントパネル NI 5911 ........................28 フロントパネル ......................29 付録...
Page 36
Synchronization メモ 対応デバイスは、ナショナルインスツルメンツ ( and Memory Core )アーキテクチャに基づいています。 対応デバイスには、 NI 5105 NI 5114 NI 5122 NI 5124 NI 5142 NI 5152 NI 5153 NI 5154 NI 5622 、 、 、 、 、 、 、 、 、 NI 5922 および が含まれます。詳細については、 『 高速デジタイザヘルプ』を参照し...
Page 48
A: SMC 付録 対応デバイスおよび デバイスのフロントパネル NI 5105 NI 5114 NI 5122 この付録では、 対応デバイスおよび デバイス 、 、 、 NI 5124 NI 5132 NI 5133 NI 5142 NI 5152 NI 5153 NI 5154 NI 5622 、 、 、 、 、 、 、 、および...
Page 50
NI 5122/5124/5142/5922 フロントパネル NI PXI-5122/5124/5142/5922 NI PCI-5122/5124/5142/5922 図 は、 および のフロントパ NI PXI-5122 NI PXIe-5122 ネルを示します。 および のフロントパネルは同じです。 NI 5122/5124/5142/5922 図 フロントパネル ni.com/jp 高速デジタイザ スタートアップガイド...
Page 54
NI 5622 フロントパネル NI PXI-5622 図 は、 のフロントパネルを示します。 NI PXIe-5622 16-Bit IF Digitizer ACCESS ACTIVE IF IN PFI 1 CLK IN CLK OUT TTL (+5 V MAX) NI 5622 図 フロントパネル NI 5622 表 は、 の信号接続を示します。 6. NI 5622 表 フロントパネルの信号接続...