Download Print this page

laguna P Flux 3 Cyclone Manual

Extractor hepa 230v

Advertisement

Quick Links

N.B. Some pictures and diagrams in this manual may have buttons and electrical configurations
which differ slightly from the machine you purchased
P | Flux 3 Cyclone
Extractor HEPA 230v
Set Up &
Product
Support
Distributed by
Code: 111771
Distributed by
Version: 2
Date: 28/11/24
DIGITAL MANUAL
DIGITAL MANUAL
111771

Advertisement

loading
Need help?

Need help?

Do you have a question about the P Flux 3 Cyclone and is the answer not in the manual?

Questions and answers

Summary of Contents for laguna P Flux 3 Cyclone

  • Page 1 P | Flux 3 Cyclone Extractor HEPA 230v Code: 111771 Distributed by Version: 2 Date: 28/11/24 DIGITAL MANUAL Set Up & Product Support Distributed by N.B. Some pictures and diagrams in this manual may have buttons and electrical configurations which differ slightly from the machine you purchased DIGITAL MANUAL 111771...
  • Page 2 Contents Safety Important Safety Instructions General Safety Rules Wiring Diagrams Power Connections Power Supply Programming Remote Control Specifications Unpacking Assembly Operation Maintenance HEPA Filter Replacement Trouble Shooting Parts Breakdown / Exploded Views Parts List Conformity Certificates Warranty...
  • Page 3 Warranty Registration Register your machine at https://lagunatools.com/policies/warranty/ To prevent voiding this warranty, all products sold must be registered within thirty (30) days of receiving the product. Registering the product will enable the original purchaser to receive notifications about important product changes, receive customer service, and be able to file a warranty claim against defective workmanship, parts, or materials.
  • Page 4 (Used without the safety alert symbol) indicates a potentially hazardous situation which, if not avoided, may result in property damage. Woodworking (and similar materials) can be dangerous if safe and proper operating procedures are not followed. As with all machinery, there are certain hazards involved with the operation of the machine.
  • Page 5 4. Do not use this machine for other than its intended use. If used for other purposes, LAGUNA TOOLS INC., disclaims any real or implied warranty and holds itself harmless from any injury that may result from that use.
  • Page 6 • Lead from lead based paint. • Crystalline silica from bricks, cement and other masonry products. • Arsenic and chromium from chemically treated lumber. Your risk of exposure varies, depending on how often you do this type of work. To reduce your exposure to these chemicals, work in a well-ventilated area and work with approved safety equipment, such as face or dust masks that are specifically designed to filter out microscopic particles.
  • Page 7 20.Make your workshop child proof with padlocks, master switches or by removing starter keys. 21.Give your work undivided attention. Looking around, carrying on a conversation and “horse-play” are careless acts that can result in serious injury. 22.Maintain a balanced stance at all times so that you do not fall or lean against the dust collector.
  • Page 8 GENERAL SAFETY RULES FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS INJURY. FOR YOUR OWN SAFETY, READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE OPERATING THE MACHINE. Learn the unit’s application and limitations as well as the specific hazards peculiar to it. KEEP WORK AREA CLEAN.
  • Page 9 Wear respirator. Fine dust that is too small to be caught in the filter will be blown into the ambient air during operation. Always wear a NIOSH-approved respirator during operation and for a short time after to reduce your risk of permanent respiratory damage. Emptying dust.
  • Page 10 SAVE THESE INSTRUCTIONS. Refer to them often and use them to instruct others. WIRING DIAGRAMS POWER CONNECTIONS 230V Figure 1: Power Connections & Wiring Mobile Dust Cyclone Manual...
  • Page 11 CONTROL PANEL 230V 230V Figure 1A: Control Panel SECONDARY JUNCTION BOX Figure 2: Internal Wiring Mobile Dust Cyclone Manual...
  • Page 12 Figure 2: Auto clean motor Internal Wiring DO NOT EXPOSE THE MACHINE TO RAIN OR OPERATE THE MACHINE IN DAMP LOCATIONS. MOTOR SPECIFICATIONS Your machine is wired for 230 volts, 50 HZ alternating current. Before connecting the machine to the power source, make sure the switch is in the "OFF" position. An (appx.) 8’ cord is included, a “plug”...
  • Page 13 1. This appliance must be connected to a grounded metal, permanent wiring system; or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the appliance. The installer, such as a qualified electrician, cut (or bend over) and insulate the grounding conductor from a field wiring supply cable.
  • Page 14 FUNCTION Full drum detection HEPA Filter detection *includes sound alert. ON/OFF button to illuminate drum ON/OFF Switch Receiver SET button On board circuit breaker Override Figure 3: High Frequency Remote Control Receiver and Manual Switch HEPA Filter detection – will illuminate when filter cleans (automatic cleaning/override) Full drum detection –...
  • Page 15 PROGRAMMING THE REMOTE CONTROL 1. Ensure the machine is switch ON before programming the remote control. 2. Press the black set button on the bottom of the remote switch until you hear two beeps. 3. Press the Remote set button on your hand held controller simultaneously with the black button until you hear three beeps to complete the set up.
  • Page 16 PRODUCT SPECIFICATIONS Motor 2200w (3hp) Power Supply 230 / 50Hz / 1PH (with 8" inlet) 17A @ 240v Running Amp Recommended Breaker Size (MCB) 30 Amps (Type D) Airflow (Traditional Method) 3831m3/hour (2253cfm) Airflow (Realistic Method) 2209m3/hour (1299cfm) Max. Static Pressure 285mm in water (11.2") Fan Diameter 390mm (15.5")
  • Page 17 UNPACKING Your Mobile Dust Cyclone comes packed in a single box. Before attempting to assemble this machine, follow these directions for unpacking: 1. Carefully cut the banding straps and remove them from the box. 2. Cut along the tape line at the top of the box. 3.
  • Page 18 For your own safety, do not connect the machine to the power source until the machine is completely assembled. Please also make sure that you read and understand the entire instruction manual. ASSEMBLY TIME ESTIMATE 5 to 6 hours Visit the Laguna Tools Video page for setup assistance. Mobile Dust Cyclone Manual...
  • Page 19 1. Remove (2) 5/16” x 5/8” hex bolts on the motor plate (shown by red arrow). Install (2) 5/16” eye bolts (not supplied) on the motor plate. With the help of another person, lift the upper cyclone assembly using a forklift. Make sure to hold the opposite side of the dust chute to prevent swaying while lifting the assembly up.
  • Page 20 With the help of another person carefully lift the upper cyclone assembly high enough to place on stands that you have completed in steps 3 and 4. Take note on precisely positioning the upper cyclone assembly onto the three lower upright supports.
  • Page 21 8. Take the intake cylinder, cyclone barrel and cyclone funnel and install 3 x 6mm foam tape to rims on each locations shown on the left. - Top rim of the intake cylinder - Top rim of the cyclone barrel - Top rim of cyclone funnel 9.
  • Page 22 11. Take the Autoclean motor and apply foam tape (3*6mm) to the shaft base as shown in photo. 12.. Loosen and remote the four bolts, washers and nuts from the gear motor. Set aside for step 14.. 13. Take the Autoclean cover plate and place over the auto clean motor.
  • Page 23 15. Attach the auto clean plate to the dust chute using (12) 3/16”*1/2” sheet metal thread bolts. 16. Take the (2) filter cleaning arms and assemble to the filter rotation shaft using (4) 1/4”*5/8” hex bolts, (8) 1/4” flat washers, and (4) 1/4” hex nuts.
  • Page 24 19.Secure and tighten the (1) 5/16”x 3/4” and (1) 5/16” x 23 x 2 flat washer on the rotation shaft base. 20. Open the canister filter shield and secure the HEPA canister filter onto the dust chute by fastening the band clamp on the top part of the HEPA canister filter.
  • Page 25 23. Secure the foot pedal support bracket to the lower upright support panel using (2) 5/16” x 1/2” carriage bolts, (2) 5/16” x 18 x 2 flat washers and (2) 5/16” hex nuts. Make sure the armrest of the support bracket is facing up.
  • Page 26 27. Secure the base of the foot pedal bar to the triangular support plate U Channel by holding the lower support plate vertically up against the foot pedal bar and securing the U channel provided onto the foot pedal bar using (2)5/16”*1-3/4”...
  • Page 27 31. Secure the movable supporting Octagon foot peddle brace on the foot peddle bar with the octagon foot peddle using (2) 3/8”*21mm hex bolts and 3/8” hex lock nuts. Make sure the bolt head is on the inside of the octagon foot peddle.
  • Page 28 34. Attach the LED light to the drum lid using (6) M4*10mm Philip HD Bolt, (6) 3/16” flat washers and (6) M4 hex nuts. 35. Attach the crossbar to the drum lid and tighten using (2) 5/16” x 3/4” Crossbar hex bolts, (4) 5/16”...
  • Page 29 38. Take the Octagon drum front and back panels and assemble together by securing with (12) M4 x 12mm sheet metal screws. 39. One the left and right side you will find three bolt holes. Take the matching side plate and secure to the outside of the panel using (6) 1/4”...
  • Page 30 42. Once completing the assembly, keep the drum laying on its side to Silicone apply silicone (not included) to the inside of the drum, including the base and the top rim of the drum before the rubber seal has been attached to seal and prevent air leakages.
  • Page 31 46. Lift the foot peddle bar. Align the Octagon drum window to the center point of the drum lid and push the drum in. Lower the foot peddle bar to seal the drum tight for normal machine operation. 47. Make sure when aligning the drum that both the left and right side lift plates are over the topping on the foot peddle bar assembly...
  • Page 32 49. Install the intake splitter. For the PFLUX2 install the 8” by 6” reducer or 8” by 4” x 2 ports to the intake using (3) M4 x 12mm sheet metal screws. Attach the rubber caps to each 4” port. PFLUX2 PFLUX3 For the PFLUX3 install the 8”...
  • Page 33 MAINTENANCE CLEANING THE FILTER This PFLUX2/PFLUX3 is equipped with auto clean every 10 minutes for 10 seconds one direction and another 10 seconds the other direction. The cleaning will continue for one cycle (10 seconds clockwise, 10 seconds counterclockwise when you shut the machine off. While the canister is cleaning the yellow LED light on the control panel will illuminate showing that it is in the process of cleaning.
  • Page 34 To maintain safe, clean air quality, the HEPA filter should be replaced after 2000 hours of operation (e.g., 8 hours/day x 250 days = 2,000 hours). Contact your dealer or Laguna Tools for a replacement HEPA filter. If your model has a “change filter indicator light” it will flash at 2,000 hours.
  • Page 35 Figure 43: Hold canister from bottom when releasing clamp 3. Remove the (4) 3/16” x 3/4” sheet metal Philip bolts, (1) 5/16” x 3/4” hex bolt and (1) 5/16” x 7/8” flat washer off the bottom of the canister filter. 4.
  • Page 36 TROUBLESHOOTING TROUBLESHOOTING Symptom Symptom Possible Cause Possible Cause Possible Solution Possible Solution Machine does Machine does Power supply switched OFF Power supply switched OFF Ensure power supply is ON and has the Ensure power supply is ON and has the not start or a not start or a or is faulty.
  • Page 37 Allow motor to cool, improve ventilation, On-board circuit breaker is press reset button. tripped. Check for broken wires or poor Wiring is open/has high connections, repair as necessary. resistance. Replace switch. Faulty power switch. TROUBLESHOOTING Impeller is loose. Impeller is loose. Check fan and cover;...
  • Page 38 EXPLODED VIEWS & PARTS 山富機械公司 2021.10.14 出圖章 Mobile Dust Cyclone Manual...
  • Page 39 SECTION A (Close up view) Mobile Dust Cyclone Manual...
  • Page 40 SECTION B (Close up view) Mobile Dust Cyclone Manual...
  • Page 41 SECTION C (Close up view) Mobile Dust Cyclone Manual...
  • Page 42 SECTION D (Close up view) Mobile Dust Cyclone Manual...
  • Page 43 No Part Name Description Q’TY No Part Name Description Q’TY LOWER UPRIGHT SUPPORT 1 PDCPF22201-1 MOTOR 2HP 9C PDCPF22201-9CV2 TWO DOT (3B) V2.2021 1 PDCPF32201-1 MOTOR 3HP 9D PDCPF22201-9D HEX BOLT 1/4”x5/8” 1A PDCPF22201-1A MOTOR GASKET PDCPF22201-9E FLAT WASHER 1/4”Xod13x1t 2 PDCPF22201-2 MOTOR SUPPORT BASE PDCPF22201-9F...
  • Page 44 No Part Name Description Q’TY No Part Name Description Q’TY 11F PDCPF22201-11F SPRING Ø42mm x 242mm L 15K PDCPF22201-15K SWIVEL CASTER OCTAGON DRUM FRONT 11G PDCPF22201-11G SKID BLOCK PDCPF22201-16V2 PANEL V2.2021 OCTAGON DRUM FOOT FLAT HEAD PHILIP BOLT 11H PDCPF22201-11H 16A PDCPF22201-16A PEDDLE 5/16”x3/4”...
  • Page 45 No. Part Name Description Q’TY No Part Name Description Q’TY 18B PDCPF22201-18B FOAM TAPE 3 x 6mm x 10M 24B PDCPF22201-24B WINDOW 18D PDCPF22201-18DV2 CYCLONE FUNNEL V2.2021 24C PDCPF22201-24C FOAM TAPE 5*20mm*1.5M 18E PDCPF22201-18E FLAT WASHER 5/16”xOD18x2t 24D PDCPF22201-24D LATCH #98 SHEET METAL BOLT 18F PDCPF22201-18F HEX BOLT 5/16”...
  • Page 46 No Part Name Description Q’TY No Part Name Description Q’TY ROUND HEAD BOLT 31I PDCPF22201-31I FLAT WASHER 1/4”*OD19*1t 43C PDCPF22201-43C M4*10mm 31J PDCPF22201-31J CANISTER FILTER SHIELD 43D PDCPF22201-43D PHILIP HD BOLT M4*6mm 31K PDCPF22201-31K HEX BOLT 1/4”*3/4” 43E PDCPF22201-43E BUZZER SUPPORT PLATE 31L PDCPF22201-31L FLAT WASHER 1/4”*OD19*1t 43F PDCPF22201-43F...
  • Page 47 - Machinery Directive: 2006/42/EC - Low Voltage Directive: 2014/35/EU The applicant: LAGUNA TOOLS, INC./ 744 Refuge Way, Suite 200, Grand Prairie, Texas 75050 USA Manufacturer: SAN FORD MACHINERY CO., LTD./ No.169, Chung shan Rd., FengYuan Dist., Taichung City 420, Taiwan (R.O.C.), Taiwan, manufacturer, declares that the machine described hereafter:...
  • Page 48 UK DECLARATION OF CONFORMITY ‘original’ Product model: P/Flux 3 Cyclone Extractor Name and address of the manufacturer: Laguna Tools Inc. 2072 Alton Parkway, Irvine, California 92606, USA. Name and address of the UK Authorised Representative: Axminster Tool Centre Ltd, Unit 10 Weycroft Avenue, Axminster, Devon EX13 5PH, United Kingdom.
  • Page 49 The labour required to install replacement parts is the responsibility of the user. Laguna Tools is not responsible for damage or loss caused by a freight company or other circumstances not in our control.
  • Page 52 Distributed by For after sales help visit axminstertools.com or call 03332 406406 The packaging is suitable for recycling. Please dispose of it in a responsible manner. EU Countries Only Do not dispose of electric tools together with household waste material. By law they must be collected and recycled separately.

This manual is also suitable for:

111771720914