Summary of Contents for Regency Fireplace Products Grandview G1200P
Page 1
Owners & Grandview G1200P ® Installation Manual Gas Fireplace MODEL: G1200P Large DV Gas Fireplace www.regency-fire.com Warning Fire or Explosion Hazard Failure to follow safety warnings exactly could result in serious injury, death, or property damage. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS •...
To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY . The Grandview™ G1200P has been designed to provide ® you with all the warmth and charm of a wood fireplace at the flick of a switch. The Grandview™ G1200P has been approved by Intertek for both safety and efficiency.
MANUFACTURED MOBILE HOME REQUIREMENTS INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency product has been tested and listed by Intertek as a Direct Vent Wall Furnace to the following ® standards: to Vented Gas Fireplace Heaters ANSI Z21.88 • CSA 2.33 and Gas-fired Appliances for Use at High Altitudes CSA 2.17-2017.
WARNING CARBON MONOXIDE POISONING HAZARD Failure to follow the steps outlined below for each appliance connected to the venting system being placed into operation could result in carbon monoxide poisoning or death. The following steps shall be followed for each appliance connected to the venting system being placed into operation, while all other appliances connected to the venting system are not in operation: 1.
safety decal This is a copy of the label that accompanies each Grandview™ G1200P Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one. ®...
MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
owner's information Gas Installation Checklist REGENCY GAS INSTALLATION CHECKLIST This general checklist does not contain all pertinent installation details or specifics and does not supersede the guidelines in this manual. Your Regency dealer/installer should use it in conjunction with manual instructions. Please follow all local codes and jurisdictions in authority. Customer: Date Installed: Install...
Page 10
owner's information REGENCY GAS INSTALLATION CHECKLIST Is the shut-off valve installed and easily accessible to the customer? Finishing If applicable, is only noncombustible material installed in the noncombustible areas? Do clearances meet installation and manual requirements? Do the mantels and/or projections comply with the installation manual? If applicable, was the solid fuel fireplace warning plate installed? Is the chase enclosure fully open the full width, height and depth above the fireplace as per the requirements noted in the framing section?
owner's information Before You Start YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN Safe installation and operation of this appliance THEY ARE IN THE SAME AREA requires common sense, however, we are required AS THE APPLIANCE. TODDLERS, by the Canadian Safety Standards and ANSI YOUNG CHILDREN AND OTHERS MAY Standards to make you aware of the following: BE SUSCEPTIBLE TO ACCIDENTAL...
owner's information Lighting Procedure The remote control system supplied has several options The first try for ignition will last approximately 60 seconds. If there is no flame ignition (rectification), the board will stop sparking for for starting/operating the appliance using the battery approximately 35 seconds.
owner's information Copy of Lighting Plate Instructions FOR YOUR SAFETY READ BEFORE LIGHTING POUR VOTRE SÉCURITÉ – À LIRE AVANT LA MISE EN MARCHE WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
owner's information Proflame II Remote Control Operating Instructions The transmitter and IFC are radio frequency devices. • The Proflame Transmitter 2 is an integrated part of the Proflame 2 System, which consists of these elements: » Proflame 2 Transmitter, in conjunction with »...
owner's information Temperature indication Display Remote-Flame Control With the system off, press the THERMOSTAT key and the MODE key at The Proflame has six (6) flame levels. With the system on and flame level the same time. Look on the transmitter's LCD screen for a C or F to the at maximum, the DOWN ARROW key will reduce the flame height by one right of the room temperature display (Fig.
owner's information Smart Thermostat (Transmitter Operation) Remote Dimmer Control (Bottom Light) The light bulb function controls the bottom lights by the dimmable light The smart thermostat function adjusts the flame height based on the control. To activate this function, use the MODE key (Fig. 1) to scroll to difference between the set point and the actual room temperatures.
owner's information Continuous Pilot/Intermittent Pilot (CPI/ 4. The screen will show either "Clr" or "Set". 5. "Clr" will remove a mode—use the up or down arrow while holding IPI) selection the ON/OFF and MODE keys (mode icon will disappear once removed). 6.
owner's information Proflame II Battery Holder Battery Replacement & Battery Pack up if 120 Volt Power is lost IMPORTANT: Battery Holder Battery Replacement & Battery Back up if 120 volt power is lost Non-Power Vent Model: Install the 4 AA batteries during power outages to run the main burner. However, the lights & optional fan will not operate. Power Vent Model: This appliance will not operate if 120 volt power is lost within the home.
owner's information Safety Screen Removal Magnetic Cover Removal Warning: Ensure power and gas is shut off and unit is cool before servicing. Lift up left side cover panel and pull towards center to release from magnets and remove (failure to lift panel may result in scratching cover panel).
owner's information Glass Door Removal 3. Tilt top of door open (approximately 45 degrees) and lift off To remove the glass door - loosen the 8 door clamp screws, 3 and out of bottom slots. Ensure door clears bottom cover each side and 2 at top.
installer's information Important Message 9. Wear gloves and safety glasses for protection while doing required maintenance. SAVE THESE INSTRUCTIONS 10. Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination. The G1200P Direct Vent Fireplace must be installed in accordance with these instructions.
installer's information Installation Checklist This includes: 4. This appliance is Listed for bedroom installations using the standard Remote (millivolt thermostat 1. Clocking the appliance to ensure the correct system). Some areas may have further 1. Locate appliance firing rate (rate noted on label 53,000 Btu/h requirements, check local codes before a) Room location (Refer to "Locating Your for natural gas and propane), after burning...
installation Clearance/Framing and Chase Vent Configurations The G1200P is designed to allow for unique installation options—depending on the desired finish. Please review the options and follow the specific clearance, framing, and finishing options for that application. The applications are as follows: Cool Wall installation: combustible materials can be installed right up to the fireplace opening with this option.
installation Cool Wall Installation (Combustible Finishing) Cool Wall Install: • Vented chase required • Combustible material can be used all around the fireplace • Combustible framing Note: Fan option is not permitted with Cool Wall Installation. Clean Front Non Cool Wall Installation (Non Combustible Finishing) Install: •...
installation Unit Assembly Prior to Installation (Nailing Flange Installation) - Cool Wall/Non Cool Wall IMPORTANT: The installation of the nailing flanges differ depending if this will be a cool wall or non cool wall installation. See following nailing flange installation instructions for both cool wall/ Top Nailing Flange non cool wall.
installation Non Cool Wall Nailing Flange Installation 1. Attach top and side nailing flanges using 6 screws provided in manual package. 2. Bend upper tabs inwards and rest these on unit top to set height. Attach sides to unit using 4 screws each. 3.
installation Cool Wall Clearances Cool Wall installation: Combustible materials can be installed right up to the fireplace opening with this option. Note: Fan option is not permitted with Cool Wall installation. The clearances listed below are minimum distances unless otherwise stated. A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials.
installation Cool Wall Mantel Clearances Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram below. Mantel Clearances Combustible 12" 6" Inches Top of Fireplace Opening To Floor...
installation Cool Wall Installation 2 x 4 or 2 x 6 - Framing NOTE: Framing may be constructed of combustible material (i.e. 2 x 4/2 x 6) and does not require steel studs. Framing Dimensions Description Cool Wall Framing Width 57-1/4"...
installation Cool Wall TV Recess Maximum TV Recess Flush TV with Hearth/Finished Floor 180 sq.in MIN. 180 sq.in MIN. CHASE VENT OPENING CHASE VENT OPENING 5-1/2” (140 mm) max. (not including finishing material) Max. Thickness of Finishing Material - 3/4” without finishing trim - 1-1/4”...
installation Cool Wall Installation - Cool Wall Conversion 4. Lift inner door and rotate tabs to lock it in place. Secure with the two (2) 1. Remove four (4) screws shown. screws removed in step 3. 2. Lift outer cover and secure with the 4 screws removed in step 1. 5 .
installation Chase Venting (Cool Wall) Note: The enclosure opening cannot be any lower than 1-1/2" from the top of the enclosure for all installations. Minimum height of enclosure from base of appliance is 88" (2235 mm). See details on next page. CHASE VENTING A minimum 180 sq.
Min 42.25” (1073 mm) installation Chase Enclosure (Cool Wall) Opening for vent When choosing to install the ventilation openings from the front, the top of the ventilation opening cannot be any lower than 1-1/2" (38mm) from the top of the chase enclosure for all installations. 4”-4.5”...
G800EC installation G1200P Chase Vent Installation—Cool Wall (Part # 796 -991 Chase Vent White) CHASE VENT INSTALLATION—COOL WALL (PART #796-991 CHASE VENT WHITE) Framed Opening must be at least 3-5/8” tall, and at least 55-3/8” wide to accomodate the Chase vent. The top of the Chase vent opening must be 1-1/2”...
installation Non Cool Wall - Clearances Non Cool Wall installation: Non-combustible required when installing materials right to the fireplace opening & no chase vent with this option. The clearances listed below are minimum distances unless otherwise stated: A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions.
installation Non Cool Wall - Mantel Clearances Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the Diagram on the right. Note: Ensure the paint that is used on the mantel and the facing is "High Quality" or the paint may discolour. Mantel Clearances Combustible Material 12"...
installation Non Cool Wall - Mantel Leg Clearances Combustible Non-combustible Non-combustible Combustible material material material material 3/4" (19 mm) 3/4" (19 mm) Mantel Leg Mantel Leg Side Opening Side Opening of Fireplace of Fireplace 12" (305 mm) 12" (305 mm) *42-1/4"...
installation Framing (Non Cool Wall) NOTE: Framing may be constructed of combustible material (i.e. 2 x 4/2 x 6) and does not require steel studs. Framing Dimensions Description G1200P - Non Cool Wall Framing Width 57-1/4" (1454 mm) Framing Height 60-1/4"...
installation Hearth Installation (Cool Wall/Non Cool Wall) Raised Hearth: If any combustible material extends above the bottom of the leveling legs, non combustible material such as tile, stone etc. must be used to act as a barrier. Combustible material cannot be exposed for the full width & depth of the hearth. See diagrams 1 & 3 Flush hearth /Finished Floor: Combustible Materials such material such as wood/vinyl flooring,linoleum, etc.
installation Finishing Material Installation - Cool Wall/Non Cool Wall The finishing material can be brought to the edge of the fireplace opening. Do NOT finish beyond the opening, doing so will prevent the screen or glass front from being attached and removed. IMPORTANT: Ensure that if this is a non cool wall application, only non combustible material is used.
installation Wall Board/Drywall/Non Combustible Board Installation G1200P (Cool Wall/Non Cool Wall) WARNING! Risk of Fire! Comply with all minimum clearances to combustibles as specified. Finishing Instructions: It is important to follow the framing and finishing instructions to ensure proper placement of fireplace into the surrounding framing/finishing materials. Wall board materials 1/2 in.
installation Vent Restrictor Installation 1. Determine the venting configuration. Note: The factory setting is Set 7: 3-1/2'' (89 mm) open. 2. Go to venting arrangements section (in the manual) to determine if a vent restrictor adjustment is required. (If required, proceed to Step 3). 3.
installation Cool Wall - Non Cool Wall Vent Pipe Clearances - Outside/Inside of Chase Enclosure This page notes all vent pipe clearances for both outside and inside of the chase enclosure. The clearances are different for both outside and inside of the chase enclosure and must be adhered to and is critical.
installation Exterior Vent Termination Requirements Minimum Clearance Requirements Canada Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) Clearance to window or door that may be opened 12"(30cm) 9" (23cm) Clearance to permanently closed window Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 29"(74cm) AstroCap/All Other 29"(74cm) AstroCap/All Other Approved Termination Caps...
installation 5" x 8" Rigid Pipe - Cross Reference Chart only 5" X 8" RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not all Rigid Pipe components are available directly from FPI. Components from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency. Note: Olympia Ventis DV venting is only approved for certain models.
Page 47
installation Description Simpson *Selkirk *Metal-Fab™ *ICC Excel *Olympia Direct Vent Pro ® Direct Temp™ Sure Seal Direct Ventis DV Attic Insulation Shield 12" 58DVA-IS* VDV-AIS05 Basic Horizontal Termination Kit (A ) 5DT-HKA TM-5HTK VDV-KW05 Horizontal Termination Kit (B) 58DVA-KHA 5DT-HKB TM-5HTK VDV-K05 Vertical Termination Kit...
Intertek WHI listing of these components. The Regency AstroCap is certified for installations using Regency venting systems as well as any specific chimney systems listed in this manual. AstroCap is a proprietary trademark of Regency Fireplace Products. | Grandview G1200P Gas Fireplace ®...
installation Horizontal Terminations - Flex Vent 5" x 8" These venting systems, in combination with the G1200P Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination Locations" section. Regency Direct Vent (Flex) System 4 foot Termination Kit (Part# 946-615), 6 foot Termination Kit (Part# 946-618) or 10 foot Termination ®...
installation Horizontal Terminations - Rigid Pipe 5" x 8" The minimum components required for a basic horizontal termination are: Horizontal Termination Cap Rigid Pipe Adaptor (770-994) Wall Thimble Length of pipe to suit wall thickness AstroCap XL (see chart) Horizontal (Part# 946-623/P) Termination Cap Wall thickness is measured from the back standoffs to the inside...
installation Venting Introduction Horizontal Terminations The G1200P uses the "balanced flue" technology co-axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber, thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.
installation Horizontal Terminations - Two 90 Elbows (Rigid/Flex Pipe 5" x 8") for Both Natural Gas/Propane One 90 elbow = Two 45 elbows. Option H + H1 With these options, maximum total pipe length is 30 feet with 2' Min. 4' Max.
installation Horizontal runs of vent must be supported Below Grade Snorkel Installation Unit Installation with every 3 feet (0.9meter). Wall straps are If the snorkel termination must be installed below Horizontal Termination - available for this purpose. grade, i.e. basement application, proper drainage 5"...
installation NOTE: Horizontal sections must be supported Unit Installation with AstroCap XL Dimensions at intervals not exceeding 3 feet Horizontal Termination - 5" x (946-623/P) (0.9 meter). (Flame picture and 8" Venting (Flex Vent Systems) performance will be affected by sags in the liner).
installation Venting Introduction Vertical Terminations The G1200P uses the "balanced flue" technology co-axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber, thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.
installation Venting Arrangements for Vertical Terminations - 5" x 8" (127 mm x 203 mm) Rigid and Flex Pipe (Propane) The shaded area in the diagram shows all allowable combinations If straight vertical and offset-to-vertical terminations, using two 90 elbows Horizontal (Feet) with rigid/flex pipe venting systems.
installation Vertical Terminations - Three 90 Elbows (Rigid/Flex Pipe 5" x 8") for Both Natural Gas/Propane One 90 elbow = Two 45 elbows. Option V + V1 H + H1 W i t h t h e s e o p t i o n s , maximum total pipe length 2' Min.
installation Unit Installation with Vertical 5. Cut a hole in the roof centered on the small drilled hole placed in the roof in Step 2. The hole Termination - 5" x 8" Venting should be of sufficient size to meet the minimum (Rigid Vent Systems) requirements for clearance to combustibles of 2".
Termination Cap installation Storm Collar Vertical Termination Flashing Vertical Terminations - Vertical Flex Vent Kit (Part #946-772) 5" (127 mm) x 8" (203 mm) Venting - Vertical Flex Vent Kit for North America (Part #946-772) Roof support Vertical Flex Vent Kit includes: Firestop spacer to prevent debris from falling into the •...
Page 60
Vertical Termination installation 5" (127 mm) x 8" (203 mm) Venting - Vertical Flex Vent Kit for North America installation (Part #946-772) 13. Slide the finished length up towards the flashing ensuring the length of pipe is a minimum of 2 feet (0.61 m) measured from installation 13.
G1200P installation LP Conversion (Part # 796-969) LP Conversion using SIT 885 PROFLAME Gas Valve G1200P using SIT 885 PROFLAME Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 7. Remove and lift out the log grate (2 screws) 10.Unscrew the NG pilot orifice with the Allen Each Kit contains one LP Conversion Kit...
Page 63
LP Conversion G1200P installation 14. Remove the valve cover by loosening two 17. Route and secure the new cable from the LP 19. Re-install the burner cover plate. screws and sliding it towards the back of regulator (stepper motor) with the velcro and Install two burner spacers with 2 screws as the unit then out.
installation G1200 Panel Installation (Part # 796-901, 796-903, 796-904, 796-905, 796-906, 796-907) Brick Panel Installation PANEL INSTALLATION IMPORTANT: THIS APPLIANCE CANNOT BE OPERATED WITHOUT EITHER BRICK PANELS OR INNER ENAMEL OR BLACK PANELS INSTALLED. These instructions are for use with the following products: 2.
Page 65
G1200 Panel Installation installation (Part # 796-901, 796-903, 796-904, 796-905, 796-906, 796-907) 5. Install the front panel(s)* by sliding it through the front of the firebox and underneath the side grate legs. *The front panel in the black steel/black glass panel set is a single For Black Steel and Black Glass Liner Panels: Remove the two part.
installation G1200 Oak/Birch/Driftwood Log Set Installation Log Set Installation (Part # 796-934, 796-931, 796-930) Read the instructions below carefully and refer to the images. If the logs are broken, do not use the unit until they are replaced. Improper positioning of the logs and may create carbon build-up and can alter the unit's performance.
Page 67
G1200 Oak/Birch/Driftwood Log Set Installation installation (Part # 796-934, 796-931, 796-930) 1. Fill the glass tray and outside of the burner tray with the 3/4" crushed glass. Mix black embers and the crushed glass to create a more realistic look. Sprinkle vermiculite crystals over glass/embers mix. 2.
Page 68
G1200 Oak/Birch/Driftwood Log Set Installation installation (Part # 796-934, 796-931, 796-930) 4. Place Log 3 on the three right pins in front of log 1. Log 3 5. Place log 6 on the two pins left of the burner. Log 6 | Grandview G1200P Gas Fireplace ®...
Page 69
G1200 Oak/Birch/Driftwood Log Set Installation installation (Part # 796-934, 796-931, 796-930) 6. Place log 7 on the two pins right of the burner. Log 7 7. Place log 8 on the left end of the burner. The log rests on the two pins on top of the burner. Log 8 8.
Page 70
G1200 Oak/Birch/Driftwood Log Set Installation installation (Part # 796-934, 796-931, 796-930) 9. Place log 4 along the grate with the notch on the left side of log 4 sitting on the second grate bar and the right side of the log resting on the third grate bar.
Page 71
G1200 Oak/Birch/Driftwood Log Set Installation installation (Part # 796-934, 796-931, 796-930) 12. Place log 11 in front of the left side of the grate. Move crystals out of the way if necessary. Log 11 Final Placement 920-770 05.23.24 Grandview G1200P Gas Fireplace | ®...
installation G1200 Faceplate Installation 3-Sided Finishing Trim Installation (Part # 796-912) 3-SIDED FINISHING TRIM INSTALLATION (PART #796-912) NOTE: This finishing trim can be adjusted from 1/2" (13 mm) minimum to 1-1/4" (32 mm) maximum depending on finishing depth. This finishing trim will not work with materials thicker than 1-1/4"...
installation G1200 Faceplate Installation 4-Sided Finishing Trim Installation (Part # 796-913) 4-SIDED FINISHING TRIM INSTALLATION (PART #796-913) NOTE: This finishing trim can be adjusted from 1/2" (13 mm) minimum to 1-1/4" (32 mm) maximum depending on finishing depth. This finishing trim will not work with materials thicker than 1-1/4"...
installation Pilot Adjustment Gas Pipe Pressure Testing NG System Data Periodically check the pilot flames. Correct The appliance must be isolated from the gas supply For 0 to 4500 feet altitude piping system by closing its individual manual shut- flame pattern has two strong blue flames: Burner Inlet Orifice Sizes: 1 flowing around the flame sensor and 1 off valve during any pressure testing of the gas...
installation Wall Mount On/Off Switch and Battery Holder Installation Required for All installations IMPORTANT INSTALLATION NOTE: The Battery Holder must be placed inside the supplied (Low Voltage) junction type wall box and installed into the wall only. DO NOT INSTALL WITHIN THE CONFINES OF THE FIREPLACE SWITCH MUST BE ACCESSIBLE Battery Holder Installation 1.
installation - general Proflame Wall Mount Transmitter WALL MOUNTING The Proflame remote control/transmitter is supplied with an adapter for wall mounting.Install the controller 59" (1.5m) above the floor level, well away from heat sources, kitchens, doors or windows. Metalllic structures or radio interferences can reduce the operative distance of the device.
installation Aeration Adjustment The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. Open the air shutter for a blue flame or close for a more yellow flame. Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty. Knob #1 -Right Burner (pull out to open, push in to close) Knob #2 - Center Burner (pull out to open, push in to close) Knob #3 - Left Burner (pull out to open, push in to close)
installation Wiring Diagram This appliance is equipped with a three pronged Install AA batteries into the back-up battery compartment for this unit to operate when power is lost. See battery back-up instructions in this (grounding) plug for your protection against manual.
installation G1200P Fan Install Installing the Optional Fan Prior to Unit Installation Into Framing Installing the Optional Fan Prior to Unit Installation Into Framing (Recommended - Part # 796-917) (Recommended - Part # 796-917) Note: Fan option is not permitted with Cool Wall 7.
installation G1200P Fan Install Fan Install After Unit Installation Fan Install After Unit Installation Note: Part # 796-980 Fan Service Gasket Kit must also be purchased separately. This includes a rear pressure relief gasket & split flow valve access plate gasket. 1.
installation operating instructions WIFI Dongle Installation (Part # 946-799) 8. Locate the dongle connection X0A on the IFC module. CAUTION: The gas supply must be shut off to the appliance & 120 Volt AC power must be disconnected, before proceeding with the WIFI kit installation. 1.
operating instructions Operating Instructions Normal Operating Sounds of Gas Appliances 1. Read and understand these instructions before operating this appliance. It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to 2. Check to see that all wiring is correct and the fact that there are various gauges and types enclosed to prevent possible shock.
operating instructions Proflame II Battery Holder Battery Replacement & Battery Pack up if 120 Volt Power is lost IMPORTANT: Non-Power Vent Model: Install the 4 AA batteries during power outages to run the main burner. However, the lights & optional fan will not operate.
operating instructions Copy of Lighting Plate Instructions FOR YOUR SAFETY READ BEFORE LIGHTING POUR VOTRE SÉCURITÉ – À LIRE AVANT LA MISE EN MARCHE WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
maintenance Maintenance Instructions Glass Replacement 2. Remove the Cap, and shine a flashlight down the Vent. Remove any bird nests, or other foreign material. In the event that you break your glass by impact, 1. Always turn off the gas valve before cleaning. 3.
maintenance Light Bulb Replacement - Bottom Lights Light Bulb Replacement -Top Light 1. Turn off fireplace and wait until it has reached room temperature. 1. Turn off fireplace and wait until it has reached room temperature. 2. Remove the Screen Barrier. See Section: Safety screen removal / 2.
maintenance Valve Replacement Removing Valve 10. Disconnect gas valve bracket by undoing 4 1. Shut off the gas and electrical supply. screws. 2. Remove the safety screen. 11. Disconnect the inlet and outlet fittings. 3. Remove all three cover panels. Installing Valve 4.
maintenance IFC Replacement IMPORTANT : Ensure 3 prong cord is disconnected from receptacle located Remove the 4 screws that secure the cover plate to the IFC box. on lower right hand side of appliance prior to servicing IFC. Then remove the cover plate. Label all wires prior to disconnection when servicing controls.
maintenance Split flow valve replacement IMPORTANT:Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. 1. Shut off the gas and electrical supply. 2. Remove the safety screen and cover panels. 3.
Gas Maintenance maintenance Gas Maintenance - Recommended Annual Routine Recommended Annual Routine Maintenance for Gas Fireplaces, Stoves and Inserts In order for your Regency appliance to continue to provide comfort to your home periodic maintenance must be performed to ensure it is operating at peak efficiency. The items in the list should be checked by a licensed gas service technician during the annual service check. Your unit may require more frequent maintenance checks if you notice any changes in how it operates. Operational changes to look for can include, but are not limited to, extended start up time, increased fan noise, residue/carbon build up, white build up on the glass/firebox, increased operating noise etc. Should any of these or other conditions arise, discontinue use and schedule a service check with your local licensed gas technician. The list below shows items your licensed service technician will need to check and service at least annually. Clean Inspect Check • Glass • Pilot assembly • Voltage on thermocouple/thermopile (mil- • Interior bricks / panels • Burner livolt models) • Burner ports & burner air shutter •...
parts list Main Assembly Grandview G1200P Gas Fireplace | ®...
Page 92
parts list Main Assembly ITEM PART # DESCRIPTION ITEM PART # DESCRIPTION 911-335 Cover Plate Switch White 796-574/P Valve Assembly - NG 911-343 Cover Plate Switch Black 796-576/P Valve Assembly - LP 796-525/P Burner Assembly Center NG/LP 911-084 Valve NG 885 SIT IPI 0.885.001 796-530/P Burner Assembly Left NG/LP 911-085...
parts list Optional Accessories ITEM PART # DESCRIPTION 796-138 Door Clamp Right 796-139 Top Door BrackeT Part Description 796-140 Door Clamp Top G1200 796-901 Brick Panel Standard Brown 796-142 Nailing Flange L/H G1200 796-902 Brick Panel Herringbone Brown 796-143 Nailing Flange R/H G1200 796-905 Brick Panel Standard Volcanic Black 796-144...
warranty Indoor Gas Product Warranty Limited Lifetime Warranty FPI Fireplace Products International Ltd. (for Canadian customers) and Fireplace Products US, Inc. (for US customers) (collectively referred to herein as “FPI”) extends this Limited Lifetime Warranty to the original purchaser of this Appliance provided the product remains in the original place of installation.
Page 95
warranty Any part(s) found to be defective during the warranty period as outlined above will be repaired or replaced at FPI’s option through an accredited distributor, dealer or pre-approved and assigned agent; provided that the defective part is returned to the distributor, dealer or agent for inspection if requested by FPI. Alternatively, FPI may, at its discretion, fully discharge all of its obligations under warranty by refunding the verified purchase price of the product to the original purchaser.
warranty Exclusions: This Limited Lifetime Warranty does not extend to paint, rust or corrosion of any kind due to a lack of maintenance or improper venting, combustion air provision, corrosive chemicals (i.e. chlorine, salt, air, etc.), door or glass gasketing, batteries, color fading, carbon/sooting of the log sets due to use and does not cover lava rock, platinum/glowing embers, vermiculite.
Page 97
warranty How to Obtain Warranty Service: Customers should contact the authorized selling dealer to obtain warranty service. In the event the authorized selling dealer is unable to provide warranty service, please contact FPI by mail at the address listed below. Please include a brief description of the problem and your address, email and telephone contact information.
warranty Warranty Registration Card Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
Page 99
warranty Grandview G1200P Gas Fireplace | ®...
Page 100
recycling PRODUCT LIFE CYCLE: By recycling your used appliances, you divert waste from your local landfills and help the environment. You also reduce the need for raw materials to manufacture new products. Contact your local municipality for appliance recycling services, local recycling programs, or appliance removal services to ensure your Regency appliance components, and packaging are properly recycled.
Page 101
notes Grandview G1200P Gas Fireplace | ®...
Page 102
notes | Grandview G1200P Gas Fireplace ®...
Need help?
Do you have a question about the Grandview G1200P and is the answer not in the manual?
Questions and answers