Paper Filter

VAMPYR CE...
TE No. 900.087.600
ET No. 668.901.268
Paper Filter Size 28
Microfilter
ET No. 668 100 151

Carrying and Storage

To make the appliance easier to store and carry,
slide the floor nozzle into the tool rail.
Parking System
For storing the suction tube and nozzle during
short pauses in use. The bracket on the nozzle is
slid into the parking rail on the appliance.


What to do, if ...

... the nozzle is hard to push
Turn down the power. Cleaning performance will
not be affected in this case.
... the motor thermal overload protection
device triggers
If the motor becomes overloaded, e.g. as the result
of the filter bag being full or a blocked accessory,
the thermal overload protection device will shut
down the motor. Turn off the appliance, unplug
from the mains, and allow the motor to cool down.
Check paper filter bag, suction tube and suction
hose, remove any blockage.
The appliance can be turned on again after approxi-
mately 30 minutes.
... the fuse has blown
The fuse may blow if you use other high power
electrical appliances on the same electrical circuit
at the same time as the vacuum cleaner is in use.
This may be prevented by setting the electronic
power regulator to minimum before turning on the
appliance and increasing the power setting after
switching on.
Your vacuum cleaner is equipped with an elec-
tronic soft start controller that reduces the start
up current of the motor, this avoids the mains fuse
blowing under normal circumstances. As a result,
at the lowest power setting the appliance may
have a start delay of approx.  seconds.
... the paper filter is damaged at some stage
and the HEPA filter is dirtied
Remove the HEPA filter, clean (tap out) and
replace.
Insert new paper filter.
... the thread lifters are worn
If the thread lifters on the suction inlet are worn
or matted, you can replace them with new thread
lifters.
You can order new thread lifters from customer
service under ET No. 668 901 690
... the lid jumps out of its hinge
If the housing lid jumps out of its hinge due to be-
ing opened too far, place it back on the housing and
press until it snaps back into place.

Additional Accessories

ROTOSOFT 1200 Turbo Brush
The ROTOSOFT 1200 makes the care of carpets
and smooth floors easier. The rotary motion of the
brushes loosens matted areas of short pile carpets
and improves their appearance.
Special Nozzle
For special care of parquet, tiles and hard floors.
Furniture Brush with Knuckle Joint
For vacuuming delicate materials and objects.
Only available from customer service.


Hide quick links: