Download Print this page

Pallas VIVA 6T Manual

Commercial & domestic ro

Advertisement

Quick Links

EN COMMERCIAL & DOMESTIC RO
FR OSMOSE INVERSE COMMERCIALE ET DOMESTIQUE
DE RO FÜR GEWERBE UND PRIVATHAUSHALTE
ES ÓSMOSIS INVERSA PARA USO COMERCIAL Y DOMÉSTICO
®
MANUAL / MANUEL
HANDBUCH / MANUAL DE
PALLAS
VIVA 6T

Advertisement

loading
Need help?

Need help?

Do you have a question about the VIVA 6T and is the answer not in the manual?

Questions and answers

Summary of Contents for Pallas VIVA 6T

  • Page 1 ® EN COMMERCIAL & DOMESTIC RO FR OSMOSE INVERSE COMMERCIALE ET DOMESTIQUE DE RO FÜR GEWERBE UND PRIVATHAUSHALTE ES ÓSMOSIS INVERSA PARA USO COMERCIAL Y DOMÉSTICO MANUAL / MANUEL HANDBUCH / MANUAL DE PALLAS VIVA 6T...
  • Page 3 PALLAS VIVA 6T PALLAS VIVA 6T MANUAL PALLAS VIVA 6T MANUEL PALLAS VIVA 6T HANDBUCH MANUAL DE PALLAS VIVA 6T COMPONENT SHEET...
  • Page 4 Packing waste should not be disposed of with domestic and other waste. Please Risk of fire collect packing wastes at waste collection centres. Electric shock warning Warnings against dangers of safety of life and property Hot surface warning | PALLAS VIVA 6T...
  • Page 5 GENERAL INFORMATION ....................6 STAGES OF CLEAN WATER PRODUCTION IN REVERSE OSMOSIS SYSTEM ...... 7 WORKING PRINCIPLE ....................7 POINTS TO BE CONSIDERED BEFORE INSTALLATION OF THE DEVICE ......8 MANUAL BOX CONTENTS AND ASSEMBLY PARTS ............9 DEVICE PROPERTIES ....................10 MANUAL INSTALLATION AND ASSEMBLY ..............
  • Page 6 Design of the reverse osmosis systemrequires var- original parts supplied byan authorized service ious technical knowledge and experience such as must be used. product water quality,raw water analysis, type of membrane etc. | PALLAS VIVA 6T...
  • Page 7 ION REMOVAL IN REVERSE OSMOSIS ION AND ORG. PESTICIDE REMOVAL (%) ION AND ORG. PESTICIDE REMOVAL (%) Aluminum 97-98 Nickel 97-99 Ammonium 85-95 Nitrate 93-96 Arsenic 94-96 Phosphate Magnesium 96-98 Potassium Bicarbonate 95-96 Radioactivity 95-98 Bromide 93-96 Radium Cadmium 96-98 Selenium Calcium 96-98...
  • Page 8 TREATMENT DEVICE FLOW SCHEME Bacteria Flora Virus Lead Treated water Waste water Raw water entrance 5 Micron black Granular activated 5 Micron carbon filter carbon filter sediment filter | PALLAS VIVA 6T...
  • Page 9 MANUAL BOX CONTENTS AND ASSEMBLY PARTS Reverse Osmosis Device Metal Ball Valve Star Faucet Pump 10” White Housing (Double O-ring) Adapter 10” Block Carbon Cartridge Filter (CTO) Tube 10” GAC Carbon Cartridge Filter (UDF) Feed water Connection Adapter 10” Inline Coconut Post Carbon Filter Shut off valve 10”...
  • Page 10 Max. Inlet Water SDI Inlet Diameter 8 - 10 mm 8 - 10 mm NOTE: The equipments used in the product are in compliance with Water Quality, CE and NSF standards. The equipments are certi ed. | PALLAS VIVA 6T...
  • Page 11 MANUAL INSTALLATION AND ASSEMBLY HOW TO ASSEMBLE SINGLE BATTERY WATER INTAKE DOUBLE BATTERY WATER INTAKE WATER INTAKE IN UNDER COUNTER Extension 3-way adapter 3-way adapter 1/4 Ball Valve 1/4 Ball Valve FIGURE A-2 1. Before the installation, turn off the valve of main feedwater line orthe inlet valve.
  • Page 12 B: Product water tube is connected to RO RO FAUCET faucet. C: The tube at the outlet of post carbon is TANK connected to product water line. WASTEWATER D: The drain tube is connected to wastewater outflow line. WATER INLET | PALLAS VIVA 6T...
  • Page 13 START-UP AFTER INSTALLATION Once you have assembled and installed all the !! IMPORTANT !! components, turn on the water supply first tocheck for leaks.Then, turn on the faucet slowly. At the first *During the rst few days after installation, air bubbles stage, water will run from the faucet slowly.
  • Page 14 The children must not play with the device. The maintenance must not be carried out by the children Do not forget to connect the power plug to the socket in models without observance of an adult. with pump. | PALLAS VIVA 6T...
  • Page 15 REPLACEMENT OF POST CARBON FILTER Turn off the water supply and open drinking wa- ter faucet. Water inlet direction Water outlet direction Loose tubing unions at inlet and outlet and dis- card the used post-carbon. Flow Disconnect the union placed at the outlet of the filter.
  • Page 16 10 (ten) years from the delivery date. The warranty is applicable only to defects in the device and we are not responsible for any other cost. No claim of indemnity can be made under any other name. | PALLAS VIVA 6T...
  • Page 17 RO tank, resulting new cartridge positions. in bacteria presence at the RO faucet. 3. An additional Pallas filter housing with John Guest 1/4” IN & OUT connections and with riser IMPORTANT MEASURES TO PREVENT tube is installed in the inlet water tubing. It is rec- BIOFILM DEVELOPMENT ommended to fix this extra housing permanently...
  • Page 18 The customer cannot claim rights or indemnity other than these undertakings. Damages or defects due to sticking any label on the device. | PALLAS VIVA 6T...
  • Page 19 IMPORTANT SAFETY AND ENVIRONMENTAL INSTRUCTIONS & CONSUMER RIGHTS INFORMATION ON POTENTIAL HAZARDS FOR RIGHT OF CHOICE PROVIDED TO CONSUMER ENVIRONMENT AND HUMAN HEALTH DURING WITH 11th ARTICLE OF LAW OPERATION 1. If the product is found defective; Please note that the ground on which electrical Consumer can renege on the contract by noti- devices are placed is dry and isolated.
  • Page 20 Bacteria in the device Disinfect your device Clogged flow restrictor Replace flow restrictor NO WASTE WATER FLOW Filter maintenance date has Replace filters and membrane element expired SLOWLY FLOW OF PURIFIED WATER FRO Faulty storage tank Replace the tank FAUCET | PALLAS EF300...
  • Page 21 FREQUENTLY ASKED QUESTIONS “How often should filters be replaced?” “I do not often use the system, does it change life span of filters and membrane?” It depends on properties, quality of water supply and usage frequency of the system. It is recommended Replacement dates of the first three filters do not to replace filters every six months.
  • Page 22 PRODUCT TYPE : WATER TREATMENT DEVICE BRAND : Pallas MODEL : Viva 6T WITH STAND WOP/WP WARRANTY : 2 YEARS MAX. REPAIR TIME : 20 WORK DAY BANDEROL AND SERAL NO DEVICE LIFETIME: WATER TREATMENT DEVICE HAS 10 (TEN) YEARS LIFETIME. Purchased product has 2 (two) years of warranty.