  • Page 1 ® ® COMMERCIAL & DOMESTIC RO COMMERCIAL & DOMESTIC RO ® PALLAS RO500 MANUAL...
  • Page 2 DEAR CUSTOMER, Water Treatment Systems use Reverse Osmosis System which is one of the advanced technologies in the world. Water Treatment Systems have been designed to remove physical, chemical and microbiological pollutants in water and to produce water in drinkable quality. Water Treatment Systems not only produce drinkable water but also produce water in best quality for meeting the needs of domestic consumption.
  • Page 3: Table Of Contents

    GENERAL INFORMATION .....................4 PURIFICATION STAGES IN UNDERCOUNTER REVERSE OSMOSIS SYSTEM ....5 WORKING PRINCIPLE ....................5 POINTS TO BE CONSIDERED BEFORE INSTALLATION OF THE DEVICE ......6 BOX CONTENTS AND ASSEMBLY PARTS ..............7 DEVICE PROPERTIES ....................8 INSTALLATION AND ASSEMBLY ...................9 MAINTENANCE AND CLEANING ..................11 START-UP AFTER MAINTENANCE ................14 WARRANTY CONDITIONS ...................15 IMPORTANT SAFETY AND ENVIRONMENTAL INSTRUCTIONS &...
  • Page 4: General Information

    Design of the reverse osmosis systemrequires va- and original parts supplied byan authorized service rious technical knowledge and experience such as must be used. product water quality,raw water analysis, type of membrane etc. | Pallas RO500...
  • Page 5: Purification Stages In Undercounter Reverse Osmosis System

    ION REMOVAL IN REVERSE OSMOSIS ION AND ORG. PESTICIDE REMOVAL ( % ) ION AND ORG. PESTICIDE REMOVAL ( % ) Aluminum 97-98 Nickel 97-99 Ammonium 85-95 Nitrate 93-96 Arsenic 94-96 Phosphate Magnesium 96-98 Potassium Bicarbonate 95-96 Radioactivity 95-98 Bromide 93-96 Radium Cadmium...
  • Page 6: Points To Be Considered Before Installation Of The Device

    TREATMENT DEVICE FLOW SCHEME TREATMENT DEVICE FLOW SCHEME Transformer Flow Restrictor Pump Selenoid Valve 5 Micron Sediment Filter Granular Activated Carbon Filter Carbon Block Filter RO membrane ST post carbon | Pallas RO500...
  • Page 7: Box Contents And Assembly Parts

    MANUAL BOX CONTENTS AND ASSEMBLY PARTS Reverse Osmosis Device 14. Tube in 8-10 mm diameter Star Faucet 15. Feed water connection parts 20” Transparent Housing 16. SV 20 Selenoid Valve 3/8” 20” Blue Mat Housing (2 Pcs) 17. Users manual and certificate of warranty 20”...
  • Page 8: Device Properties

    95 % ~ 99 % FLOW SCHEME ST - 33 Selonoid Valve High Pressure Ball Valve Low Pressure Pump Transformer Tank FLOW SCHEME Tanks are externally sold in 200/300/400/500 GPD units.The above visual is for the device including tank. | Pallas RO500...
  • Page 9: Installation And Assembly

    MANUAL INSTALLATION AND ASSEMBLY HOW TO ASSEMBLE SINGLE BATTERY WATER INTAKE DOUBLE BATTERY WATER INTAKE WATER INTAKE IN UNDER COUNTER Extension 3-way adapter 3-way adapter 3/8 Ball Valve 3/8 Ball Valve FIGURE A-2 1. Before the installation, turn off the valve of main feedwater line orthe inlet valve.
  • Page 10 Ÿ Drill a 6 mm hole on the outflow tube. sure and so, overflow. Ÿ Tighten the clamp (side with the seal) in correct Ÿ After these steps, RO unit is ready to be installed. relative position of the hole to prevent any pos- | Pallas RO500...
  • Page 11: Maintenance And Cleaning

    TANK TAP INSTALLATION INSTALLING CARTRIDGES Ÿ There is a pre-set amount of air in the water If the cartridge filters have packages, remove tank. Please do not touch the air valve. them and insert in proper housings according to the order shown in the installation diagram. Screw Ÿ...
  • Page 12 Do not forget to connect the power plug to the socket in The treatment device must not be supplied with hot water. Oth- models with pump. erwise, all filters will be damaged and the device will be out of warranty. | Pallas RO500...
  • Page 13 REPLACEMENT OF POST CARBON FILTER Ÿ Turn off the water supply and open drinking wa- Water inlet direction Water outlet direction ter faucet. Ÿ Loose tubing unions at inlet and outlet and dis- Flow card the used post-carbon. Ÿ Disconnect the union placed at the outlet of the filter.
  • Page 14: Start-Up After Maintenance

    10 (ten) years from the delivery date. The warranty is applicable only to defects in the device and we are not responsible for any other cost. No claim of indemnity can be made under any other name. | Pallas RO500...
  • Page 15: Warranty Conditions

    WARRANTY CONDITIONS EXCLUSIONS FROM THIS WARRANTY Ÿ Damages or defects due to natural disasters. Ÿ Damages or defects resulting from running the The warranty excludes defects caused by the misu- device with water below 5oC degrees and above se of water treatment device. The consumer should 40oC degrees.
  • Page 16: Important Safety And Environmental Instructions & Consumer Rights

    | Pallas RO500...
  • Page 17: Troubleshooting

    TROUBLESHOOTING Problem Possible Cause Action No water supply Ceck if water enters the system Faulty connection to power Check the electrical connections THE DEVICE DOES source NOT WORK Damaged adapter Replace it or contact service Faulty low pressure switch Replace it or contact service Water supply valve is closed Open the water supply valve NO PRODUCT (PURIFIED)
  • Page 18: Frequently Asked Questions

    Contact the seller, dealer, agent or representative office where you have purchased the product. The warranty peri- od of the product is 2 (two) years. You can contact us within this period in case of any dispute, damage or defect not resulting from misuse; | Pallas RO500...
  • Page 19 INVOICE DATE / NO DELIVERY DATE AND LOCATION AUTHORIZED SIGNATURE / STAMP PRODUCT TYPE : WATER TREATMENT DEVICE BRAND : Pallas RO500 MODEL : HIGH FLOW 200/300/400/500 GPD WARRANTY : 2 YEARS MAX. REPAIR TIME : 20 WORK DAY BANDEROL AND SERAL NO DEVICE LIFETIME: WATER TREATMENT DEVICE HAS 10 (TEN) YEARS LIFETIME.
  • Page 20 The product you have purchased complies with the standards of 2014/35/EU; DECLARATION OF CONFORMITY We hereby declare that we manufacture the products in compliance with the requirements of Low Voltage Directive 2014/35 / EU as described below. Product : Pallas RO500 Models : HIGH FLOW 200/300/400/500 GPD Conformity Assessment...