  • Page 1 Owner's Manual Original Instructions Commercial Air Conditioners Multi Variable Air Conditioners Ducted Type Indoor Unit Models: GMV-ND80PLS/C-T GMV-ND90PLS/C-T GMV-ND100PLS/C-T GMV-ND112PLS/C-T GMV-ND125PLS/C-T GMV-ND140PLS/C-T...
  • Page 2 To Users Thank you for selecting Gree product. Please read this instruction manual carefully before installing and using the product, so as to master and correctly use the product. In order to guide you to correctly install and use our product and achieve expected operating effect, we hereby instruct as below:...
  • Page 3 Exception Clauses Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons: (1) Damage the product due to improper use or misuse of the product; (2) Alter, change, maintain or use the product with other equipment without abiding by the instruction manual of manufacturer;...
  • Page 4 Contents 1 Safety Notices (Please be sure to abide them) ............1 2 Product Introductions ....................3 2.1 Names of Key Components ..................... 3 2.2 Rated Working Condition ......................3 3 Preparations for Installation ..................3 3.1 Standard Fittings ........................4 3.2 Location for Installation ......................
  • Page 5 Multi Variable Air Conditioners Ducted Type Indoor Unit 1 Safety Notices (Please be sure to abide them) WARNING: If not abide strictly, it may cause severe damage to the unit or the people. NOTE: If not abide them strictly, it may cause slight or medium damage to the unit or the people.
  • Page 6 Multi Variable Air Conditioners Ducted Type Indoor Unit Diameter of power cord should When the power cord is be large enough. The damaged connected, please fix the power cord and connection wire electric box cover properly to must be replaced with special avoid safety accidents.
  • Page 7 Any personal injury or property loss caused by improper installation, improper debug, and unnecessary repair or not following the instructions of this manual should not be the responsibility of Gree Electric Appliances, Inc. of Zhuhai. Correct Disposal of this product This marking indicates that this product should not be disposed with other household wastes throughout the EU.
  • Page 8 Multi Variable Air Conditioners Ducted Type Indoor Unit 3.1 Standard Fittings Please use the supplied standard fittings listed below as instructed. Name Appearance Q'ty Usage Wired Controller To control the indoor unit To connect with the hard PVC drain Drain Hose Assembly pipe Union nut To connect the exit tube...
  • Page 9 Multi Variable Air Conditioners Ducted Type Indoor Unit NOTES: ① Installation of the unit must be in accordance with National Electric Codes and local regulations. ② Improper installation will affect unit’s performance, so do not install the unit by yourself. Please contact local dealer to arrange professional technicians for the installation.
  • Page 10 Multi Variable Air Conditioners Ducted Type Indoor Unit Total Length L (m) of Communication Cable Material Type Wire size Material Standard Remarks between Indoor Unit and Indoor (Outdoor) Unit 1. If the wire diameter is enlarged to 2×1 Light/Ordinary mm², the total communication line polyvinyl length can reach 1500 m.
  • Page 11 Multi Variable Air Conditioners Ducted Type Indoor Unit 4 Installation Instructions 4.1 Installation of Indoor Unit 4.1.1 Outline Dimension and Installation Spots Equip with an inspection hatch after lifting the unit. For the convenience of maintenance, the service port should be on one side of the electric box and below unit’s lower level. Below are the outline dimension applicable to indoor units of GMV-ND80~140PLS/C-T。...
  • Page 12 Multi Variable Air Conditioners Ducted Type Indoor Unit Unit:mm Fig.4.1.3 Fig.4.1.4 2) Insert the M10 expansion bolt into the hole and then knock the nail into the bolt, as shown in Fig.4.1.5, and then remove the paper pattern. CAUTION: The length of bolt depends on the installation height of the unit, bolts are field supplied. Fig.4.1.5 (2) Install the indoor unit temporarily Assemble suspension bolt on the expansion bolt, attach the hanger bracket to the suspension bolt.
  • Page 13 Multi Variable Air Conditioners Ducted Type Indoor Unit After the indoor unit is installed, remember to check the horizontal status of the whole unit. It should be horizontal from front to back and slant 1% from left to right, following the drainage direction. Fig.4.1.7 (5) Remove the washer locating plate and then tighten the nut on it.
  • Page 14 Multi Variable Air Conditioners Ducted Type Indoor Unit (6) Install drainage pipe according to the following figure and arrange insulation to the drainage pipe. Improper installation may lead to water leakage and damp the furniture and other things in the room.
  • Page 15 Multi Variable Air Conditioners Ducted Type Indoor Unit Unit:mm Fig.4.3.4 (5) Install the trap as shown in following Fig.4.3.5. Fig.4.3.5 (6) Install one trap for each unit. (7) Convenience for cleaning trap in the future should be considered when installing it. (8) The horizontal pipe can be connected to vertical pipe in the same level;...
  • Page 16 Multi Variable Air Conditioners Ducted Type Indoor Unit Unit: mm Fig.4.3.9 Model A(mm) B(mm) C(mm) GMV-ND80PLS/C-T GMV-ND90PLS/C-T GMV-ND100PLS/C-T 1050 1000 GMV-ND112PLS/C-T GMV-ND125PLS/C-T GMV-ND140PLS/C-T (10) Drain pipes should have a downward slope of at least 1%~2%, in order to prevent pipes from sagging, install hanger bracket at intervals of 1000~1500mm.
  • Page 17 Multi Variable Air Conditioners Ducted Type Indoor Unit (3) It is strongly recommend to do the drain test before ceiling decoration. Fig.4.3.11 4.4 Installation of Air Duct CAUTION: ① There should be insulating layer on air-out duct, air-return duct and fresh air duct to avoid heat loss and moisture.
  • Page 18 Multi Variable Air Conditioners Ducted Type Indoor Unit (2) Installation of Circular Duct Fig.4.4.2 4.4.2 Shape and Size of Air Outlet and Air-return Opening Range of Capacity GMV-ND80~140PLS/C-T. Fig.4.4.3 Air Outlet Fig.4.4.4 Air-return Opening Unit:mm Size of Air Outlet Size of Air-return Opening Model GMV-ND80PLS/C-T 1016...
  • Page 19 Multi Variable Air Conditioners Ducted Type Indoor Unit 4.4.3 Installation of the Return Air Duct (1) The default installation location of the rectangular flange is at the back and the return air cover plate is at the bottom, as shown in Fig.4.4.5. Fig.4.4.5 (2) If the bottom return air is desired, just change the place of the rectangular flange and the return air cover plate.
  • Page 20 Multi Variable Air Conditioners Ducted Type Indoor Unit Fig.4.4.7 Fig.4.4.8 4.5 Installation of Wired Controller Please refer to User Manual of Wired Controller for the installation details. Note: When installation is finished, the unit must be tested and debugged before operation. Please refer to Instruction Manual of ODU for auto addressing and debugging details.
  • Page 21 Multi Variable Air Conditioners Ducted Type Indoor Unit 4) Use the screwdriver for tightening the terminal. Unit: mm Fig.5.1.1 Fig.5.1.2 5.2 Power Cord Connection WARNING! ① Every unit should be equipped with a circuit breaker for short-circuit and overload protection. ②...
  • Page 22 Multi Variable Air Conditioners Ducted Type Indoor Unit 5.3 Connection of Communication Wire between Indoor Unit and Outdoor Unit (or indoor unit) (1) Detach the electric box lid. (2) Let the Communication cable pass through the wiring through-holes. (3) Connect the communication wire to terminal D1 and D2 of indoor 4-bit wiring board, as shown in Fig.5.3.1.
  • Page 23 Multi Variable Air Conditioners Ducted Type Indoor Unit Fig.5.4.1 5.5 Illuminate for Connection of Wired Controller and Indoor Units Network (1) Communication wire of indoor unit and outdoor unit (or indoor unit) is connected to D1, D2. (2) Wired controller is connected to H1, H2. (3) One indoor unit can connect two wired controllers that must be set as master one and slave one.
  • Page 24 Multi Variable Air Conditioners Ducted Type Indoor Unit Fig.5.5...
  • Page 25 Multi Variable Air Conditioners Ducted Type Indoor Unit 6 Setting of External Static Pressure Working range for external static pressure of this series of duct type unit is 0 Pa~80 Pa. For corresponding external static pressure to the respective static pressure notch please see as below. The setting of static pressure for indoor fan can be done via wired controller.
  • Page 26 Multi Variable Air Conditioners Ducted Type Indoor Unit 8 The Table of Error Codes for Indoor Unit Error Error Error Content Content Content Code Code Code Quantity Of Group Control Indoor Unit Error Water Temperature Error Indoor Units Setting Error Indoor Fan Indoor Units Incompatibility Jumper Cap Error...
  • Page 27 Multi Variable Air Conditioners Ducted Type Indoor Unit 9 Troubleshooting The air conditioner is not expected to be serviced by users. Incorrect repair may cause electric shock or fire, so please contact an authorized service center for professional service. The following checks prior to contact may save your time and money.