Gree GMV-ND15G/B6B-T Owner's Manual
Hide thumbs Also See for GMV-ND15G/B6B-T:

Advertisement

Owner's Manual
Original Instructions
Commercial Air Conditioners
Multi Variable Air Conditioners
Wall Mounted Type Indoor Unit
Models
:
GMV-ND15G/B6B-T
GMV-ND18G/B6B-T
GMV-ND22G/B6B-T
GMV-ND28G/B6B-T
GMV-ND36G/B6B-T
GMV-ND45G/B6B-T
GMV-ND50G/B6B-T
GMV-ND56G/B6B-T
GMV-ND63G/B6B-T
GMV-ND71G/B6B-T
GMV-ND22G/C4B-T
GMV-ND28G/C4B-T
GMV-ND36G/C4B-T
GMV-ND45G/C4B-T
GMV-ND50G/C4B-T
GMV-ND56G/C4B-T
GMV-ND63G/C4B-T
GMV-ND71G/C4B-T
GMV-ND22G/C2B-T
GMV-ND28G/C2B-T
GMV-ND36G/C2B-T
GMV-ND45G/C2B-T
GMV-ND50G/C2B-T
GMV-ND56G/C2B-T
GMV-ND63G/C2B-T
GMV-ND71G/C2B-T
GMV-ND22G/D2B-T
GMV-ND28G/D2B-T
GMV-ND36G/D2B-T
GMV-ND45G/D2B-T
GMV-ND50G/D2B-T
GMV-ND56G/D2B-T
GMV-ND63G/D2B-T
GMV-ND71G/D2B-T
GMV-ND15G/B4B-T
GMV-ND18G/B4B-T
GMV-ND22G/B4B-T
GMV-ND28G/B4B-T
GMV-ND36G/B4B-T
GMV-ND45G/B4B-T
GMV-ND50G/B4B-T
GMV-ND56G/B4B-T
GMV-ND63G/B4B-T
GMV-ND71G/B4B-T
GMV-ND80G/B4B-T
GMV-ND90G/B4B-T
GMV-ND100G/B4B-T

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GMV-ND15G/B6B-T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gree GMV-ND15G/B6B-T

  • Page 1 Owner's Manual Original Instructions Commercial Air Conditioners Multi Variable Air Conditioners Wall Mounted Type Indoor Unit Models GMV-ND15G/B6B-T GMV-ND22G/C2B-T GMV-ND15G/B4B-T GMV-ND18G/B6B-T GMV-ND28G/C2B-T GMV-ND18G/B4B-T GMV-ND22G/B6B-T GMV-ND36G/C2B-T GMV-ND22G/B4B-T GMV-ND28G/B6B-T GMV-ND45G/C2B-T GMV-ND28G/B4B-T GMV-ND36G/B6B-T GMV-ND50G/C2B-T GMV-ND36G/B4B-T GMV-ND45G/B6B-T GMV-ND56G/C2B-T GMV-ND45G/B4B-T GMV-ND50G/B6B-T GMV-ND63G/C2B-T GMV-ND50G/B4B-T GMV-ND56G/B6B-T GMV-ND71G/C2B-T...
  • Page 2 To Users Thank you for selecting Gree product. Please read this instruction manual carefully before installing and using the product, so as to master and correctly use the product. In order to guide you to correctly install and use our product and achieve expected...
  • Page 3 Exception Clauses Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons: (1) Damage the product due to improper use or misuse of the product; (2) Alter, change, maintain or use the product with other equipment without abiding by the instruction manual of manufacturer;...
  • Page 4: Table Of Contents

    Contents 1 Safety Notices (Please be Sure to Abide) ............1 2 Product Introduction ..................4 2.1 Outline of the Unit and Main Parts ................4 2.2 Rated Operating Condition ..................4 3 Preparations for Installation ................5 3.1 Location for Installation ....................5 3.2 Schematic Diagram of Installation Space ..............
  • Page 5: Safety Notices (Please Be Sure To Abide)

    Multi Variable Air Conditioners Wall Mounted Type Indoor Unit 1 Safety Notices (Please be Sure to Abide) WARNING! If not abide strictly, it may cause severe damage to the unit or the people. NOTE! If not abide strictly, it may cause slight or medium damage to the unit or the people.
  • Page 6 Multi Variable Air Conditioners Wall Mounted Type Indoor Unit Installation should be conducted by the dealer Follow this manual to or qualified personnel. complete the installation Please do not attempt to work. Please read this install the air conditioner manual carefully before by yourself.
  • Page 7 Multi Variable Air Conditioners Wall Mounted Type Indoor Unit Open the door and window frequently to Do not insert fingers or keep good ventilation for objects into air outlet or avoiding oxygen deficit air return grille. when gas heater or oil heater is used in the room.
  • Page 8: Product Introduction

    Any personal injury or property loss caused by improper installation, improper debug, unnecessary repair or not following the instructions of this manual should not be the responsibility of Gree Electric Appliances, Inc. of Zhuhai. 2 Product Introduction 2.1 Outline of the Unit and Main Parts Fig 2.1...
  • Page 9: Preparations For Installation

    ② Please contact the local Gree appointed service center before installation. Any malfunctioncaused by the unit that is not installed by the Gree appointed service center would probably not be dealt with on time because of the inconvenience of the business contact.
  • Page 10: Requirements For Communication Line

    Multi Variable Air Conditioners Wall Mounted Type Indoor Unit Standard. ⑦ This unit shall only be connected to an appliance suitable for the same refrigerant. 3.3 Requirements for Communication Line NOTE! If the unit is installed in the place with strong electromagnetic interference, shielded wire must be applied on the communication wire between indoor unit and wired controller.
  • Page 11: Wiring Requirements

    3.4 Wiring Requirements Minimum Minimum Air Switch Power Cord Sectional Area Sectional Area Model Capacity Size of Ground of Power Wire(mm Cord(mm GMV-ND15G/B6B-T,GMV-ND18G/B6B-T 220-240V ~ GMV-ND22G/B6B-T,GMV-ND28G/B6B-T 50Hz GMV-ND36G/B6B-T,GMV-ND45G/B6B-T 208-230V ~ GMV-ND50G/B6B-T,GMV-ND56G/B6B-T 60Hz GMV-ND63G/B6B-T,GMV-ND71G/B6B-T GMV-ND15G/B4B-T,GMV-ND18G/B4B-T GMV-ND22G/B4B-T,GMV-ND28G/B4B-T 220-240V ~ GMV-ND36G/B4B-T,GMV-ND45G/B4B-T 50Hz GMV-ND50G/B4B-T,GMV-ND56G/B4B-T...
  • Page 12: Installation Instructions

    3mm (The same for both indoor unit and outdoor unit). 4 Installation Instructions 4.1 Installation of Indoor Unit Fig 4.1 Below are dimensions of W, H, D for different models: Unit: mm Item Model GMV-ND15G/B6B-T,GMV-ND18G/B6B-T GMV-ND22G/B6B-T,GMV-ND28G/B6B-T,GMV-ND36G/B6B-T GMV-ND15G/B4B-T,GMV-ND18G/B4B-T GMV-ND22G/B4B-T,GMV-ND28G/B4B-T,GMV-ND36G/B4B-T GMV-ND22G/C4B-T,GMV-ND28G/C4B-T,GMV-ND36G/C4B-T GMV-ND22G/C2B-T,GMV-ND28G/C2B-T,GMV-ND36G/C2B-T GMV-ND22G/D2B-T,GMV-ND28G/D2B-T,GMV-ND36G/D2B-T GMV-ND45G/B6B-T,GMV-ND50G/B6B-T...
  • Page 13: The Installation Of The Rear Panel

    Multi Variable Air Conditioners Wall Mounted Type Indoor Unit 4.2 The Installation of the Rear Panel Unit: mm Fig 4.2 ① Find the horizontal position by the seton method; since the drainage pipe is on the left side, it is necessary to adjust the rear panel to make its left side a little bit lower. ②...
  • Page 14: Installation The Connection Pipes

    Multi Variable Air Conditioners Wall Mounted Type Indoor Unit Fig 4.3 4.5 Installation the Connection Pipes Connect the ends of the connection pipe with two leading pipes, and then tighten the joint nuts tightly. Connect the connect pipe with the two relative leading pipe, tie the nut on tie –in of the connect pipe tightly.
  • Page 15: Wiring Work

    Multi Variable Air Conditioners Wall Mounted Type Indoor Unit 5 Wiring Work WARNING! Before obtaining access to terminals, all supply circuits must be disconnected. NOTES! ① Units must be earthed securely, or it may cause electric shock. ② Please carefully read the wiring diagram before carry out the wiring work, incorrect wiring could cause malfunction or even damage the unit.
  • Page 16: Power Cord Connection

    Multi Variable Air Conditioners Wall Mounted Type Indoor Unit Unit: mm Fig 5.1 Fig 5.2 5.2 Power Cord Connection NOTE! All indoor units must be unified of power supply so that they can be powered ON/OFF at the same time. If it’s with a plug, the power socket must be installed the place where is within your reach.
  • Page 17: Connection Of Communication Line Of Wired Controller

    Multi Variable Air Conditioners Wall Mounted Type Indoor Unit (3) Connect the communication line to terminal D1 and D2 on the 4-digit wiring board of indoor unit, as shown in Fig 5.4(D1D2 Rated Voltage/Current 5V/100mA,ClassⅡ). Fig 5.4 Fig 5.5 (4) Secure the communication line with the wire clamp on the electric box. (5) In order to ensure the reliability of communication between IDU and ODU and the communication among each IDU, add a matched resistance (supplied in a package before ex-factory) on the wiring board of the last indoor unit in a series connection.
  • Page 18: Installation Of The Indoor Unit

    (4) Guarantee that the installation height of the indoor unit should be 2.5m above the floor. Fig 5.6 5.7 Connection of External Water Pump The external water pump applicable model: GMV-ND15G/B6B-T,GMV-ND15G/B4B-T,GMV-ND18G/B6B-T,GMV-ND18G/B4B-T, GMV-ND22G/B6B-T,GMV-ND22G/B4B-T,GMV-ND22G/C4B-T,GMV-ND22G/C2B-T, GMV-ND22G/D2B-T,GMV-ND28G/B6B-T,GMV-ND28G/B4B-T,GMV-ND28G/C4B-T, GMV-ND28G/C2B-T,GMV-ND28G/D2B-T,GMV-ND36G/B6B-T,GMV-ND36G/B4B-T,...
  • Page 19 Multi Variable Air Conditioners Wall Mounted Type Indoor Unit GMV-ND36G/C4B-T,GMV-ND36G/C2B-T,GMV-ND36G/D2B-T,GMV-ND45G/B6B-T, GMV-ND45G/B4B-T,GMV-ND45G/C4B-T,GMV-ND45G/C2B-T,GMV-ND45G/D2B-T, GMV-ND50G/B6B-T,GMV-ND50G/B4B-T,GMV-ND50G/C4B-T,GMV-ND50G/C2B-T, GMV-ND50G/D2B-T,GMV-ND56G/B6B-T,GMV-ND56G/B4B-T,GMV-ND56G/C4B-T, GMV-ND56G/C2B-T,GMV-ND56G/D2B-T,GMV-ND63G/B6B-T,GMV-ND63G/B4B-T, GMV-ND63G/C4B-T,GMV-ND63G/C2B-T,GMV-ND63G/D2B-T,GMV-ND71G/B6B-T, GMV-ND71G/B4B-T,GMV-ND71G/C4B-T,GMV-ND71G/C2B-T,GMV-ND71G/D2B-T. The external water pump is purchased by the user, and the water pump is selected according to the requirements. The installation must be carried out by a professional according to the local laws and regulations and the pump manual.
  • Page 20: The Best Usage Method

    Multi Variable Air Conditioners Wall Mounted Type Indoor Unit Fig 5.7 6 The Best Usage Method Fig 6.1 (1) Adjust to proper indoor temperature, too cool of indoor temperature is not good for health.
  • Page 21 Multi Variable Air Conditioners Wall Mounted Type Indoor Unit (2) This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 22: Maintenance Method

    Multi Variable Air Conditioners Wall Mounted Type Indoor Unit 7 Maintenance Method WARNING ! (1) Do turn off the unit and cut off the power when cleaning the air conditioner, otherwise electric shock may happen. (2) Do not make the air conditioner wet or electric shock may be incurred; ensure that the air conditioner will not be cleaned by water rinsing under any circumstance.
  • Page 23: Check Before The Usage Season

    Multi Variable Air Conditioners Wall Mounted Type Indoor Unit NOTES! ① Do not clean the filter by hot water higher than 45°C for preventing fade or deformation. ② Do not burn it on fire or the filter would catches fire or deformation. (3) Install air filter Install the air filter properly along the arrow direction, making the side marked “Front”...
  • Page 24: Malfunction Analyzing

    Multi Variable Air Conditioners Wall Mounted Type Indoor Unit 9 Malfunction Analyzing WARNING: Do not repair the air conditioner by yourself for the incorrect repair would lead to electric shock or fire. Please contact the service center and have the unit repaired by the specialized personnel.
  • Page 25: After-Sales Service

    Multi Variable Air Conditioners Wall Mounted Type Indoor Unit 9.2 After-Sales Service When quality or other problems arise upon the purchased air conditioner, please contact the local service center. 10 Adjusting Method of The Air Direction 10.1 Adjusting Air Direction Up and Down (1) Controlling the guide louver motor by the wireless remote controller can make the guide louver swing up and down, or makes the guide louver stop at a certain angle to have air supplied.

Table of Contents