BA00295P/00/EN/19.22-00
71556693
2022-05-04
Valid as of software version
04.01.zz
Products
Operating Instructions
Cerabar S PMC71, PMP71,
PMP75
Process pressure measurement
PROFIBUS PA
Solutions
Services

Advertisement

loading
Need help?

Need help?

Do you have a question about the Cerabar S PMC71 and is the answer not in the manual?

Questions and answers

Summary of Contents for Endress+Hauser Cerabar S PMC71

  • Page 1 Products Solutions Services BA00295P/00/EN/19.22-00 71556693 2022-05-04 Valid as of software version 04.01.zz Operating Instructions Cerabar S PMC71, PMP71, PMP75 Process pressure measurement PROFIBUS PA...
  • Page 2 The manufacturer reserves the right to modify technical data without prior notice. Your Endress+Hauser distributor will supply you with current information and updates to this manual. Endress+Hauser...
  • Page 3 ....48 Endress+Hauser operating program ..51 HistoROM®/M-DAT (optional) ....51 Locking/unlocking operation .
  • Page 4 About this document Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA About this document Document function These Operating Instructions contain all the information that is required in the various phases of the life cycle of the device: from product identification, incoming acceptance and storage, to mounting, connection, operation and commissioning through to troubleshooting, maintenance and disposal.
  • Page 5 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA About this document 1.2.4 Symbols for certain types of Information Symbol Meaning Permitted Indicates procedures, processes or actions that are allowed. A0011182 Not permitted Indicates procedures, processes or actions that are forbidden.
  • Page 6 The manufacturer is not liable for damage caused by improper or unintended use. Clarification for borderline cases: In the case of special fluids and fluids used for cleaning, Endress+Hauser is glad to provide assistance in clarifying the corrosion resistance of wetted materials, but does not accept any warranty or liability.
  • Page 7 It meets general safety standards and legal requirements. It also conforms to the EC directives listed in the device-specific EC Declaration of Conformity. Endress+Hauser confirms this by affixing the CE mark to the device.
  • Page 8 Identification Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Identification Product identification The measuring instrument can be identified in the following ways: • Nameplate specifications • Order code with breakdown of the device features on the delivery note • Enter the serial number from the nameplates in W@M Device Viewer (www.endress.com/deviceviewer): All the information about the measuring instrument is...
  • Page 9 The devices comply with the applicable standards and regulations as listed in the EC Declaration of Conformity and thus comply with the statutory requirements of the EC Directives. Endress+Hauser confirms the successful testing of the device by affixing to it the CE mark.
  • Page 10 Mounting Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Mounting Incoming acceptance, transport, storage 4.1.1 Incoming acceptance • Check the packaging and contents for any signs of damage. • Check the shipment, make sure nothing is missing and that the scope of supply matches your order.
  • Page 11 • It is possible to rotate the housing by up to 380° to ensure optimum readability of the on- site display. See also → ä 19, "Rotating the housing". • Endress+Hauser offers a mounting bracket for installation on pipes or walls. See also → ä 16, "Wall and pipe mounting (optional)".
  • Page 12 Mounting Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA ‣ Mount the device as follows. ® • Keep the pressure compensation and GORE-TEX filter (1) free from contamination and water. • Cerabar S devices without diaphragm seals are mounted in accordance with the same guidelines as a manometer (DIN EN 837-2).
  • Page 13 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Mounting Mount the Cerabar S with shutoff device above the tapping point so that any condensate can flow into the process. Pressure measurement in steams A0051850 Fig. 2: Measuring arrangement for pressure measurement in steams...
  • Page 14 Mounting Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Pressure measurement in liquids A0051851 Fig. 3: Measuring arrangement for pressure measurement in liquids Cerabar S Shutoff device Mount the Cerabar S with the shutoff device below or at the same level as the tapping point.
  • Page 15 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Mounting NOTICE Incorrect handling! Damage to the device! ‣ The diaphragm seal and the pressure sensor together form a closed, calibrated system which is filled with filling fluid through a hole in the upper part. This hole is sealed and not to be opened.
  • Page 16 Mounting Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA 4.4.5 Wall and pipe mounting (optional) Endress+Hauser offers a mounting bracket for installation on pipes or walls (for pipe diameters from 1 ¼" to 2"). ø42...60 (1.65...2.36) 122 (4.8) 140 (5.51) 158 (6.22)
  • Page 17 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Mounting 4.4.6 Assembling and mounting the "separate housing" version r ³ 120 (4.72) mm (in) P01-PMx7xxxx-11-xx-xx-xx-011 Fig. 6: "Separate housing" version In the "separate housing" version, the sensor is supplied with process connection and cable fitted.
  • Page 18 Material" in the order code up to, and including, 40 bar sensors (600 psi), Endress+Hauser recommends welding on the diaphragm seals as follows: the total welding depth of the fillet weld is 1 mm (0.04 in) at an external diameter of 16 mm (0.63 in).
  • Page 19 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Mounting 4.4.8 Rotating the housing The housing can be rotated by up to 380° by loosening the setscrew. A0019996 1. T14 housing: loosen the setscrew with a 2 mm (0.08 in) Allen key.
  • Page 20 Mounting Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Post-installation check After installing the device, carry out the following checks: • Are all screws firmly tightened? • Are the housing covers screwed down tight? Endress+Hauser...
  • Page 21 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Wiring Wiring Connecting the device WARNING Risk of electric shock! If the operating voltage is > 35 VDC: Dangerous contact voltage at terminals. ‣ In a wet environment, do not open the cover if voltage is present.
  • Page 22 Wiring Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA 5.1.1 Connection of devices with M12 plug PIN assignment for M12 plug Meaning Signal + Not assigned Signal – Earth A0011175 5.1.2 Devices with 7/8" plug PIN assignment for 7/8" plug Meaning Signal –...
  • Page 23 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Wiring 5.2.2 Current consumption Up to HW Version 1.10: 11 mA ±1 mA, switch-on current corresponds to IEC 61158-2, Clause 21. As of HW Version 02.00: 13 mA ±1 mA, switch-on current corresponds to IEC 61158-2, Clause 21.
  • Page 24 Operation Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Operation Feature 20 "Output; operation" in the order code provides you with information on the operating options available to you. Version in the order code Operation PROFIBUS PA; external and LCD...
  • Page 25 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Operation The following table illustrates the symbols that can appear on the on-site display. Four symbols may appear at the same time. Symbol Meaning Alarm symbol – Symbol flashing: warning, device continues measuring.
  • Page 26 Operation Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA 6.2.2 Function of operating elements Operating elements Meaning – Position adjustment (zero point correction): Press key for at least 3 seconds. If the LED on the electronic insert lights up briefly, the pressure applied has been accepted for position adjustment.
  • Page 27 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Operation 6.2.3 Function of operating elements – on-site display connected Operating key(s) Meaning – Navigate upwards in the picklist – Edit the numerical values or characters within a function – Navigate downwards in the picklist –...
  • Page 28 6.3.2 Number of devices • The Endress+Hauser Cerabar S devices meet the requirements of the FISCO model. • Due to the low current consumption, the following can be operated at one bus segment when installation is performed according to FISCO Up to HW Version 1.10:...
  • Page 29 Special configuration and operating programs from various manufacturers are available for configuring the device, such as the Endress+Hauser operating program FieldCare (see → ä 51, "Endress+Hauser operating program"). This operating program makes it possible to configure the PROFIBUS PA and device-specific parameters. The predefined function blocks allow uniform access to network and device data.
  • Page 30 Operation Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Table of the identification numbers: Value for "IDENT Identification Selection text Status Diagnostics NUMBER SEL" number 0x9700 0x9700 Classic status / New diagnostic messages (Profile-specific 3.x) Condensed status 0x1501 0x1501 Classic status...
  • Page 31 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Operation 6.3.5 Device identification and addressing Note the following: • An address must be assigned to every PROFIBUS PA device. Only when the address is configured correctly will the measuring instrument be recognized by the control system/ master.
  • Page 32 Operation Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Configuring a new address via FieldCare. DIP switch 8 (SW/HW) is set to "On" (SW): Using the "Device Operation" menu → select the "Connect" option. The "Open Connection Wizard" screen is displayed.
  • Page 33 Each device receives an ID number from the Profibus User Organization (PNO). The name of the Device Master File (GSD) is derived from this. For Endress+Hauser, this ID No. starts with the manufacturer ID "15xx". The Profile 3.02 GSD file with the "Condensed status" option is only compatible with SW 04.01.zz and must be imported individually into the configuration tool.
  • Page 34 Operation Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA The Device Master Files (GSD) for Endress+Hauser devices can be acquired in the following manner: • Endress+Hauser website: http://www.endress.com → Downloads → Search for "GSD" • PNO website: http://www.profibus.com (Products – Product Guide) •...
  • Page 35 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Operation 6.3.7 Cyclic data exchange Cerabar S block model Measured variable Sensor Display Physical Block Signal evaluation with scaling Device-specific characteristics, e.g. software revision SEL. DISPLAY VAL. PA Input value Main Process...
  • Page 36 Operation Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Parameter description Parameter name Description OUT VALUE This parameter shows the digital output value of the Analog Input Block. Menu path FieldCare: PROFILE VIEW → ANALOG INPUT BLOCK → AI PARAMETER Menu path on-site display: GROUP SELECTION →...
  • Page 37 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Operation Modules for the cyclic data diagram Cerabar S makes the following modules available for the cyclic data diagram: • Main process value Depending on the operating mode selected, a pressure or level value is transmitted here.
  • Page 38 Operation Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Status codes Cerabar S supports the "Condensed status" function as defined in the PNO specification. However, the "Classic" status is also supported to ensure compatibility with older devices in the S series and due to the profile-specific identification number ("0x9700").
  • Page 39 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Operation Condensed status: The main reason for implementing the "Condensed" status mode in the Profibus PA Profile 3.02 is to clarify the diagnostic events resulting from use in the PCS/DCS and in the operating station.
  • Page 40 Operation Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA 6.3.8 Acyclic data exchange Acyclic data exchange is used: • To transmit commissioning or maintenance parameters • To display measured variables not contained in the cyclic data diagram. Using acyclic data exchange, device parameters can be modified even when the device is involved in cyclic data exchange with a PLC.
  • Page 41 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Operation 6.3.9 Slot/index tables The device parameters are listed in the following tables. You can access the parameters by means of the slot and index number. The individual blocks each contain standard parameters, block parameters and manufacturer-specific parameters.
  • Page 42 Operation Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Physical Block Parameter Slot Index Object type Data type Size [byte] Storage Class Read Write Physical Block standard parameters BLOCK OBJECT Record DS-32 STATIC REVISION NO. Simple Unsigned16 Simple Visible String...
  • Page 43 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Operation Parameter Slot Index Object type Data type Size [byte] Storage Class Read Write PCB TEMPERATURE Simple Float Allowed Min.TEMP Simple Float Allowed Max. TEMP Simple Float PCB COUNT T>Tmax Simple Unsigned16 PCB MAX.
  • Page 44 Operation Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Transducer Block Parameter Slot Index Object type Data type Size [byte] Storage Class Read Write Transducer Block standard parameters BLOCK OBJECT Record DS-32 STATIC REVISION NO. Simple Unsigned16 Simple Visible String...
  • Page 45 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Operation Parameter Slot Index Object type Data type Size [byte] Storage Class Read Write COUNTER T < Tmin Simple Unsigned16 MEAS. VAL. TREND Simple Unsigned8 TOTALIZER 1 Simple Visible String TOTAL. 1 OVERFLOW...
  • Page 46 Operation Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Parameter Slot Index Object type Data type Size [byte] Storage Class Read Write HI TRIM MEASURED Simple Float PERCENT UNIT Simple Unsigned16 X-VAL: Simple Float Y-VAL: Simple Float MASS FLOW UNIT...
  • Page 47 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Operation 6.3.10 Data format In the case of PROFIBUS PA, the cyclic transmission of analog values to the PLC is effected in data blocks 5 bytes long. The measured value is portrayed in the first 4 bytes in the form of floating point numbers in accordance with IEEE standard.
  • Page 48 Operation Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA On-site operation – on-site display connected If the on-site display is connected, the three operating keys are used to navigate through the operating menu, see → ä 27, "Function of operating elements – on-site display connected".
  • Page 49 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Operation 6.4.2 Selecting an option Example: select "English" as the language of the menu. On-site display Operation "German" has been selected as the menu language. A  in front of the menu text indicates the option that is currently active.
  • Page 50 Operation Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA 6.4.4 Editing a value Example: adjusting DAMPING VALUE function from 2.0 s to 30.0 s. See also → ä 27, "Function of operating elements – on-site display connected". On-site display Operation The on-site display shows the parameter to be changed.
  • Page 51 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Operation Endress+Hauser operating program The FieldCare operating program is an Endress+Hauser asset management tool based on FDT technology. Using FieldCare, you can configure all Endress+Hauser devices and devices from other manufacturers that support the FDT standard.
  • Page 52 Operation Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA 6.6.1 Copying configuration data ➁ ➀ Zero Display Sensor S D A 0 1 2 3 4 5 6 7 8 Address HW-Version: SW-Version: P01-xxxxxxxx-19-xx-xx-xx-110 Electronic insert with optional HistoROM®/M-DAT memory module ®...
  • Page 53 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Operation Copying configuration data from a HistoROM®/M-DAT to a device: Operation must be unlocked. Disconnect the device from the supply voltage. ® Attach the HistoROM /M-DAT module to the electronic insert. Configuration data from ®...
  • Page 54 Operation Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA The table provides an overview of the locking functions: Locking via View/read Modify/write via Unlocking via parameters On-site Remote DIP switch On-site Remote display operation display operation DIP switch On-site display Remote operation Parameters which refer to how the display appears, e.g.
  • Page 55 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Operation • Any customer-specific configuration carried out at the factory is not affected by a reset (customer-specific configuration remains). If, after a reset, you wish the parameters to be reset to the factory settings, please contact Endress+Hauser Service.
  • Page 56 Operation Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Reset code Description and effect 2506 PowerUp reset (warm start) – This reset resets all the parameters in the RAM. Data are read back anew from the EEPROM (processor is initialized again).
  • Page 57 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Commissioning Commissioning The device is configured for the "Pressure" measuring mode at the factory. The measuring range and the unit in which the measured value is transmitted, as well as the digital output value of the Analog Input Block OUT, correspond to the data on the nameplate.
  • Page 58 Commissioning Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Commissioning via Class 2 master (FieldCare) The procedure for commissioning and operating the FieldCare program is described in the integrated FieldCare online help. Proceed as follows to commission the device: Check the hardware write protection on the electronic insert (see → ä 53, "Locking/ unlocking operation").
  • Page 59 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Commissioning 7.4.2 FieldCare The MEASURING MODE parameter is displayed in the QUICK SETUP menus in FieldCare and in the BASIC SETUP function group. The following measuring modes are available: • Pressure • Level The LANGUAGE parameter is arranged in the DISPLAY group.
  • Page 60 Commissioning Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Position adjustment Due to the orientation of the device, there may be a shift in the measured value, i.e. when the vessel is empty or partly filled, the measured value does not display zero. There are three ways to perform position adjustment.
  • Page 61 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Commissioning Pressure measurement 7.6.1 Information regarding pressure measurement • A Quick Setup menu is available for both the "Pressure" and "Level" measuring modes and guides you through the most important basic functions. You specify which Quick Setup menu should be displayed with the setting in the MEASURING MODE parameter.
  • Page 62 Commissioning Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA On-site operation FieldCare POS. ZERO ADJUST POS. ZERO ADJUST Due to the orientation of the device, there may be a Due to the orientation of the device, there may be a shift in the measured value.
  • Page 63 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Commissioning Level measurement 7.7.1 Information on level measurement • The Level and Pressure operating modes each have a quick setup menu which guides you through the most important basic functions. See → ä 65 for the "Level" quick setup menu.
  • Page 64 Commissioning Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA 7.7.2 Overview of level measurement Measuring task LEVEL SELECTION/ Measured Description Note Measured value LEVEL MODE variable options display The measured variable is in LEVEL SELECTION: Via OUTPUT UNIT – Calibration with –...
  • Page 65 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Commissioning 7.7.3 Quick Setup menu for the Level measuring mode • Some parameters are only displayed if other parameters are appropriately configured. For example, the EMPTY CALIB. parameter is only displayed in the following cases: –...
  • Page 66 Commissioning Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA On-site operation FieldCare GROUP SELECTION Select the QUICK SETUP menu. POS. ZERO ADJUST POS. ZERO ADJUST Due to the orientation of the device, there may be a Due to the orientation of the device, there may be a shift in the measured value.
  • Page 67 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Commissioning Scaling OUT value In the Analog Input Block, the input value or input range can be scaled in accordance with the automation requirements. Example: The measuring range 0 to 500 mbar (0 to 7.5 psi) should be rescaled to 0 to 10000.
  • Page 68 Commissioning Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA System units (SET UNIT TO BUS) The Cerabar S on-site display and the MEASURED VALUE (FieldCare) show the same value as standard. The bar graph on the on-site display corresponds to the standardized value of the Analog Input Block.
  • Page 69 (1) free from contamination and water. P01-PMC71xxx-17-xx-xx-xx-001 Cleaning instructions Endress+Hauser provides flushing rings as an accessory to enable cleaning of the process membrane without removing the transmitter from the process. For further information, please contact your local Endress+Hauser Sales Center. 8.1.1...
  • Page 70 → For the error messages, see Page 77, Section 8.1.1 "On-site display error messages". • For support and further information, please contact Endress+Hauser Service. • → See also Section 8.4, 8.5 and 8.6. • The PROFIBUS status is updated depending on the message type, or depending on the setting for flexible alarms.
  • Page 71 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Troubleshooting Code Corresponds Message Message/description Cause Measure Priority to NA 64 category NE 107 110 (A110) Alarm Failure (F) F>Checksum error in – The supply voltage is – Reestablish supply voltage. If EEPROM: configuration disconnected when writing.
  • Page 72 Troubleshooting Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Code Corresponds Message Message/description Cause Measure Priority to NA 64 category NE 107 Warning Function C>Linearization table Note! From software version "03.10.xx" onwards, there is no min. (W604) check (C) not valid. Less than 2 span for the Y-points.
  • Page 73 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Troubleshooting Code Corresponds Message Message/description Cause Measure Priority to NA 64 category NE 107 Warning Maintenance M>Configuration in – Configuration (parameters) in – Copy data from the device to (W706) required (M)
  • Page 74 Troubleshooting Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Code Corresponds Message Message/description Cause Measure Priority to NA 64 category NE 107 717 (E717) Error Out of S>Transmitter over – The temperature measured in – Reduce ambient temperature. 34 specification...
  • Page 75 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Troubleshooting Code Corresponds Message Message/description Cause Measure Priority to NA 64 category NE 107 727 (E727) Error Out of S>Sensor pressure – Electromagnetic effects are – Block off electromagnetic specification error - overrange...
  • Page 76 Troubleshooting Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Code Corresponds Message Message/description Cause Measure Priority to NA 64 category NE 107 733 (E733) Error Out of S>URV Temp. User – Temperature measured value – Check system/temperature specification limits exceeded has overshot the value specified measured value.
  • Page 77 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Troubleshooting Code Corresponds Message Message/description Cause Measure Priority to NA 64 category NE 107 744 (A744) Alarm Failure (F) F>Main electronic PCB – Electromagnetic effects are – Restart the device. Perform error greater than specifications in reset (Code 2506 or 33062).
  • Page 78 Troubleshooting Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Response of outputs to errors The device differentiates between the message types "Alarm", "Warning" and "Error". → See the following table and Page 70, Section 8.1 "Messages". Output A (Alarm) W (Warning)
  • Page 79 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Troubleshooting 9.2.1 Analog Input Block If the Analog Input Block receives an input or simulation value with the status BAD, the Analog Input Block uses the failsafe mode defined in the FSAFE_TYPE parameter.
  • Page 80 Troubleshooting Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA In the FieldCare navigation window, go to PROFILE VIEW → PB Parameter In the default setting, all the bits have "Uncertain" for "Status Select Events", apart from 716. Select the "Bad" option for the row "Status Select Event 115". Press ENTER to confirm your entries.
  • Page 81 Explosion hazard! When repairing Ex-certified devices, please note the following: • Repairs to Ex-certified devices must be carried out by Endress+Hauser Service or by specialist personnel according to national regulations. • Relevant standards, national hazardous area regulations and Safety Instructions and Certificates must be observed.
  • Page 82 Troubleshooting Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Software history Date Software version Changes to the software 12.2004 03.00.zz Original software. Compatible with: ® – Update ToF Tool – Field Tool Package, version 2.03 or higher 05.2007 04.00.zz – Operation via on-site display with three keys implemented.
  • Page 83 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Technical data Technical data For technical data, please refer to Technical Information Cerabar S TI00383P. Endress+Hauser...
  • Page 84 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Index Acyclic data exchange ......40 Nameplate .
  • Page 85 Cerabar S PMC71, PMP71, PMP75 with PROFIBUS PA Wall mounting ........16 Warnings .
  • Page 86 71556693 www.addresses.endress.com...

This manual is also suitable for:

Cerabar s pmp71Cerabar s pmp75