Page 1
Features Qorvo recommends that the user evaluate the EVK functionality with an RF PA and with the EVK connected to a PC running the graphical user interface (GUI) software. The GUI allows the user to enable/disable the outputs and to customize the exact voltage and current requirements for the specific RF PA being tested.
Page 2
USER’S GUIDE EVK Contents The EVK ships with the following: • ACT43750EVK3 PCB • USB-TO-I2C Dongle and cables • The EVK does not ship with an RF PA Appendix Application Note 1: Safe Operation at High Drain Switching Frequency Application Note 2: How to Configure Bias Current and Current Limit...
Page 3
USER’S GUIDE Figure 2. ACT43750EVK3 SET-UP Figure 3. ACT43750EVK3 + QPD1004EVK SET-UP www.qorvo.com October 2024 Rev 2.0 | Subject to change without notice 3 of 27...
Page 4
11) If over-temperature protection is desired, an NTC can be placed on the RF PA and wired to the J6 NTC connector. The NTC along with R5 and R8 will set the over-temperature shutdown threshold. Recommended Operating Conditions The ACT43750EVK3 operates with a 10V to 55V drain voltage and supports up to a 10A load. Parameter Description...
Page 5
GUI Installation • Get GUI files from the Qorvo website • Plug the Qorvo dongle USB-TO-I2C cable into a free USB port. • The USB driver will be automatically installed. • Double click on the ACT43750 Customer GUI Rev0.5.exe to start the ACT43750EVK.
Page 6
• Confirm the drain voltage is zero • Note: “Enable Vdrain” button is only for continuous operation. For pulse operation, Apply PWM pulse to ENTX pin. www.qorvo.com October 2024 Rev 2.0 | Subject to change without notice 6 of 27...
Page 7
USER’S GUIDE QPD1004EVB and ACT43750EVK3 System Test Note 1: Calibration resistor change is necessary for certain RFPA dc bias current. Please refer to App Note 2. Note 2: RFPA drain capacitor change is necessary. Please refer to App Note 5 for drain capacitance and drain switching operation.
Page 8
6) Wait for 2 seconds to discharge the drain voltage. 7) Turn off the 12V bias supply Test Results Test condition, Input voltage=50V, Bias voltage=12V, Resistor load www.qorvo.com October 2024 Rev 2.0 | Subject to change without notice 8 of 27...
Page 9
USER’S GUIDE Test condition, Input voltage=50V, Bias voltage=12V, RFPA QPD1004 www.qorvo.com October 2024 Rev 2.0 | Subject to change without notice 9 of 27...
Page 11
USER’S GUIDE Layout Figure 7. Assembly Top Layer www.qorvo.com October 2024 Rev 2.0 | Subject to change without notice 11 of 27...
Page 12
USER’S GUIDE Figure 8. Top Layer Silk Screen www.qorvo.com October 2024 Rev 2.0 | Subject to change without notice 12 of 27...
Page 13
USER’S GUIDE Figure 9. Layout Top Layer www.qorvo.com October 2024 Rev 2.0 | Subject to change without notice 13 of 27...
Page 14
USER’S GUIDE Figure 10. Layer 2 – GND Plane www.qorvo.com October 2024 Rev 2.0 | Subject to change without notice 14 of 27...
Page 15
USER’S GUIDE Figure 11. Layer 3 - GND Plane www.qorvo.com October 2024 Rev 2.0 | Subject to change without notice 15 of 27...
Page 16
USER’S GUIDE Figure 12. Layout Bottom Layer www.qorvo.com October 2024 Rev 2.0 | Subject to change without notice 16 of 27...
Page 17
Standard 10nF/25V Ceramic, Capacitor, C0805_H Standard Standard Ceramic, Capacitor, C0805_H Standard Standard 22uF/16V Ceramic, Capacitor, C0603_H Standard Standard 470pF/16V Ceramic, Capacitor, C0603_H Standard Standard 100nF/16V Ceramic, www.qorvo.com October 2024 Rev 2.0 | Subject to change without notice 17 of 27...
Page 18
2.54, Male, 4P Unshroude 2.54, Male, 4P L25xx_MAPI_ Murata DFE252010F- Inductor, 6.8uH/1.1A Electronic 6R8M=P2 MMCX MMCX1, MMCX THT Taoglas PCB.MMCXFSTJ.HT Prefer MMCX2 limited or 1_1634009_0 Taoglas www.qorvo.com October 2024 Rev 2.0 | Subject to change without notice 18 of 27...
Page 19
R15, R17 R0805_H Standard Standard Resistor, R12, R13 R0805_H Standard Standard Resistor, R0603_H Standard Standard Resistor, R0603_H Standard Standard Resistor, R19, R0603_H Standard Standard R21, R22, R23 www.qorvo.com October 2024 Rev 2.0 | Subject to change without notice 19 of 27...
Page 20
Standard 100k R26, R28, Resistor, R27, R32 R0603_H Standard Standard Resistor, R29, R0603_H Standard Standard R30, R31 PCB-0354-01 Standard Standard PCB-0354-01 HP34_QFN37- Qorvo ACT43750-101 ACT43750-101 ACT43750 www.qorvo.com October 2024 Rev 2.0 | Subject to change without notice 20 of 27...
Page 21
Step 3, Find the resistors power rating that is higher than the requirement with a good margin Step 4, Locate R10 in the board, and replace it with higher power resistors www.qorvo.com October 2024 Rev 2.0 | Subject to change without notice...
Page 22
ID – RF PA drain current, unit A. R1 – Current limit resistance, unit mΩ. Please refer to the schematics and layout for resistor connection and location. www.qorvo.com October 2024 Rev 2.0 | Subject to change without notice 22 of 27...
Page 23
To reduce falling switching time, R12 and R13 should have smaller resistance value. To increase falling switching time, R12 and R13 should be larger resistance value. Please refer to schematics and layout for resistor connection and location. www.qorvo.com October 2024 Rev 2.0 | Subject to change without notice 23 of 27...
Page 24
Dongle connector GND is aligned with the AGND pin of J11 as shown in Figure 3. GUI PWM function is available. Figure 3. Old dongle connection at J11 Dongle is “Qorvo Rev2.0”, which works with ACT43750 Customer GUI Rev0.5 Version 1 Dongle connector on PCB needs flip 180 deg.
Page 25
The rise time depends on the gate resistance R11. The default gate resistance R11=10Ω. The rise time is 10ns. The R11=100Ω, the rise time is 100ns. www.qorvo.com October 2024 Rev 2.0 | Subject to change without notice 25 of 27...
Page 26
1. RF PA input signal is off. 2. Pull ENTX pin to logic low. 3. Turn off the drain power supply 4. Turn off the 12V bias voltage. www.qorvo.com October 2024 Rev 2.0 | Subject to change without notice 26 of 27...
Need help?
Do you have a question about the ACT43750EVK3 and is the answer not in the manual?