  • Page 1 Gigabit Ethernet over VDSL2 Converter/Bridge VC-231G/VC-231GF/VC-234G User’s Manual...
  • Page 2 PLANET has made every effort to ensure that this User’s Manual is accurate; PLANET disclaims liability for any inaccuracies or omissions that may have occurred.
  • Page 3 Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately. Revision PLANET Gigabit Ethernet over VDSL2 Converter/Bridge User's Manual For Models: VC-231G/VC-231GF/VC-234G Revision: 1.5 (DECEMBER 2024)
  • Page 4 Table of Contents 1. Package Contents ..................5 2. Product Features.................... 6 3. Hardware Introduction ................... 8 3.1 Front Panel and LED Indicators ..............8 3.2 Rear Panel and Mode DIP Switch ............10 3.3 Power Information ................13 4. Connecting and Using The VDSL2 Bridge ............14 4.1 Point-to-Point Application -- LAN to LAN Connection .........
  • Page 5 1. Package Contents Thank you for purchasing PLANET Gigabit Ethernet over VDSL Converter/Bridge Series, VC-231G, VC-231GF and VC-234G. In the following sections, the term “VDSL2 Bridge” means the VC-231G Series. Open the box of the VDSL2 Bridge and carefully unpack it. The box should contain...
  • Page 6 VDSL2 IP DSLAM for last-mile solution  Point-to-point application: LAN to LAN extension over phone wire  VC-231G: up to 200/200Mbps bandwidth (in G.INP, Sym, 8dB mode)  VC-231GF/VC-234G: up to 150/150Mbps bandwidth (in G.INP, Sym, 8dB mode)  ITU-T G.993.2 VDSL2 standard ...
  • Page 7  Advantage of minimum installation time (Simply by Plug and Play)  Supports extensive LED indicators for network diagnosis.  Compact size and wall-mountable design  Metal case  Easy installation; ideal solution for space-limited locations  The VC-231G/VC-231GF co-works with PLANET Media Chassis family (MC-700/ MC-1500/MC-1500R/MC-1500R48).
  • Page 8 LNK/ VC-231G 10/100/1000 Ethernet over VDSL Converter Figure 3-1-1: VC-231G Front Panel  10/100/1000BASE-T RJ45 connector for Ethernet  RJ11 connector for VDSL2 for connecting to IP DSLAM or another VDSL2 Bridge  LEDs for power, Ethernet and VDSL  VC-231GF Front Panel...
  • Page 9 Indicates the VDSL2 Bridge is running in CO mode. Green Indicates the VDSL2 Bridge is running in CPE mode. Green  10/100/1000BASE-T Port for VC-231G Color Function To indicate that the port is operating at 10/100/1000Mbps. To indicate that the VDSL Converter is actively sending or...
  • Page 10 3.2 Rear Panel and DIP Switch  VC-231G and VC-231GF Rear Panel 5V DC Mode Tran. Band Asym. 12dB G.INP Interleave Sym. Figure 3-2-1: VC-231G and VC-231GF Rear Panel  DIP switch  DC jack (DC input) for power adapter...
  • Page 11  DC jack (DC input) for power adapter  DC Power Jack The VC-231G Series requires 5V DC, 2A power input, which conforms to the bundled AC adapter. Should you have the issue of power connection, please contact your local sales representative.
  • Page 12  DIP Switch The Ethernet over VDSL2 Bridge provides 4 selective transmission modes. By switching the transmission modes, you can obtain a best transmission mode to suit your phone line quality or distance of connectivity. The following is the summary table of transmission setting, bandwidth and distance extensibility tested for AWG 24 (0.5mm) twisted-pair without noise and cross talk.
  • Page 13 Planet’s media chassis. Should you have the issue of power connection, please contact your local sales representative. Please keep the AC-DC adapter as a spare part when the VC-231G/VC-231GF is installed to a media chassis. Width of DC Receptacle: 2.5mm 2.5mm...
  • Page 14 Point-to-Multipoint (one multi-port CO device to multi CPE devices) and allows data and voice to work on the same telephone lines.  The VC-231G and VC-231GF provide only one RJ11 connector for VDSL2 port to build VDSL2 connection. For voice device connection, there is an additional splitter from the package of the VC-231G and VC-231GF.
  • Page 15 Router VC-231G 1000 VC-231GF Data Voice VDSL2 VDSL2 RJ11 Line Cord RJ11 Line Cord RJ11 Line Cord Splitter Splitter Phone 1000BASE-SX/LX Fiber Optic 1000 1000BASE-T UTP Telephone wire VDSL2 VDSL2 Phone RJ11 Phone Jack VC-234G 12dB 12dB Asym. Asym. 5V DC G.INP...
  • Page 16 4.1 Point-to-Point Application -- LAN to LAN Connection Two sets of the VDSL2 Bridge could be used to link two local area networks that are located in a different place. Through the normal telephone line, it could be set up as a 150/150Mbps (G.INP, Sym, 8dB) symmetric backbone, with one being VDSL2 Bridge must be Master (CO mode) and the other one, Slave (CPE mode).
  • Page 17 VC-820M) operates as a CO Master and needs to be placed in the wiring center (MDF room) and connects to the telephone line system.  On the other hand, it needs to install one or many CPE Slaves (the VC-231G or VC-234G VDSL Bridge) on the individual client side and connect to the multi-port Master through the telephone lines.
  • Page 18 Refer to the following procedure to set up the VDSL2 Bridge to IP DSLAM connection. 1. [Remote End] Set the remote IP DSLAM/VDSL2 switch to CO mode with proper VDSL2 profile. 2. [Local End] Set the VDSL2 Bridge at the local end to CPE mode from the DIP switch.
  • Page 19 5. Product Specifications Product VC-231G VC-231GF VC-234G Hardware Specifications 1 10/100/1000 1 1000BASE-SX/LX/ 4 10/100/1000 BASE-T BX SFP slot BASE-T LAN Ports RJ45 auto-MDI/ RJ45 auto-MDI/ MDI-X port MDI-X ports 1 VDSL2 RJ11 female phone jack VDSL Port Twisted-pair telephone wires (AWG24 or better) up to 1.4km...
  • Page 20 IEEE 802.3az 1000BASE-SX/LX(VC-231GF) IEEE 802.3x Full-duplex Flow Control IEEE 802.1p Class of Service Standards ITU-T G.993.1 VDSL Compliance ITU-T G.997.1 ITU-T G.993.2 VDSL2 (Profile 17a/30a/35b support) VC-231G ITU-T G.993.2 VDSL2 (Profile 17a/30a Support) VC-231GF/ VC-234G ITU-T G.993.5 G.Vectoring & G.INP ITU-T G.998...
  • Page 21 6. Performance Table  VC-231G Performance*, unit: Mbps Interleave (Downstream/Upstream)** Distance Asymmetric Symmetric (meter) 12dB 12dB 200m 260/56 267/57 175/180 165/172 400m 180/53 161/49 109/130 107/115 600m 111/48 93/46 75/93 65/82 800m 68/39 56/33 50/65 43/55 1000m 53/18 47/14 37/33...
  • Page 22  VC-231GF Performance*, unit: Mbps Interleave (Downstream/Upstream) Distance Asymmetric Symmetric** (meter) 12dB 12dB 200m 190/87 178/84 147/139 135/127 400m 161/60 143/53 112/110 96/96 600m 118/36 99/32 75/73 61/59 800m 59/24 48/22 44/44 40/40 1000m 47/7 41/5 26/25 23/18 1200m 39/4 33/3 24/13 22/9...
  • Page 23 44/5 35/3 25/13 23/8 1400m 24/2 21/1 10/5 *: The actual data rate will vary on the quality of the copper wire and environmental factors. **: Use VC-231GF as CO and VC-231G or VC-234G as CPE for superior VDSL2 performance.
  • Page 24 7. Troubleshooting SYMPTOM: VDSL LNK LED does not light up after wire is connected to the VDSL port. CHECKPOINT: 1. Verify the length of the wire (not more than 1.4km) connected between the VDSL2 Bridges. Please also try to adjust the DIP switch or the VDSL2 Bridge to the other SNR mode.
  • Page 25 A3: In order to guarantee the stability and better quality of network, we suggest the distance should not exceed 1.4 kilometers. Q4: What is the best data rate for the VDSL2 Bridge? A4: The best data rate of the VC-231G/VC-231GF is up to 190Mbps/100Mbps (downstream/upstream) asymmetric...
  • Page 26 9. Customer Support Thank you for purchasing PLANET products. You can browse our online FAQ resource on PLANET Website first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team.
  • Page 27 Step 4: Refer to chapter 3.3 Power Information for power supply to the VDSL2 Bridge. Before mounting the device to the wall, please check the location of the electrical outlet and the length of the Ethernet cable. Ø7mm Ø2mm VC-231G/VC-231GF Switch Bottom Side RJ11 Ethe rnet over VDS L Con vert er RJ45...
  • Page 28 VC-234G Switch Bottom Side RJ45 UTP Cable Chassis Installation and Rack Mounting (VC-231G and VC-231GF) To install the Ethernet over VDSL2 Bridge in a 10-inch or 19-inch Converter Chassis with standard rack, follow the instructions described below. Step 1: Place your VDSL2 Bridge on a hard flat surface, with the front panel positioned towards your front side.
  • Page 29 Step 3: Attach a rack-mount bracket to each side of the Converter Chassis with supplied screws attached to the package. Step 4: After the brackets are attached to the Converter Chassis, use suitable screws to securely attach the brackets to the rack. Step 5: Connect one end of the power cable to the 10-inch or 19-inch Converter Chassis.