Download Print this page

Anritsu Company ShockLine ME7868A Quick Start Manual

Vector network analyzers verification kits and performance verification software

Advertisement

Quick Links

Quick Start Guide
ShockLine™ Series
Vector Network Analyzers
Verification Kits and
Performance Verification Software
MS46122B Series VNAs
MS46322B Series VNAs
MS46522B Series VNAs
MS46524B Series VNAs
ME7868A Modular VNA
ME7869A Modular VNA
Anritsu Company
490 Jarvis Drive
Morgan Hill, CA 95037-2809
USA
http://www.anritsu.com
Part Number: 10410-00766
Published: November 2024
Copyright 2024 Anritsu Company. All Rights Reserved.
Revision: D

Advertisement

loading
Need help?

Need help?

Do you have a question about the ShockLine ME7868A and is the answer not in the manual?

Questions and answers

Summary of Contents for Anritsu Company ShockLine ME7868A

  • Page 1 MS46322B Series VNAs MS46522B Series VNAs MS46524B Series VNAs ME7868A Modular VNA ME7869A Modular VNA Anritsu Company Part Number: 10410-00766 490 Jarvis Drive Revision: D Morgan Hill, CA 95037-2809 Published: November 2024 Copyright 2024 Anritsu Company. All Rights Reserved. http://www.anritsu.com...
  • Page 2 1. Introduction to the Quick Start Guide Introduction to the Quick Start Guide This quick start guide provides a brief overview of the installation and use of ShockLine Verification Kits and the 3-2300-610 Performance Verification Software (PVS) with ShockLine Series VNAs. Verification Kit Components The supplied Verification Kit components are listed in the general reference figure below.
  • Page 3 2. Verification Kit Components Calibration/Verification Kit Components Summary of Required Hardware The table below summarizes the required support hardware for each verification kit. Only one calibration kit, automatic or manual, is required. Note also that the PC Controller and the connecting GPIB cable are required for all VNAs and all verification kits.
  • Page 4 3. Required PC Controller Equipment Required PC Controller Equipment The following Personal Computer (PC) Controller equipment and software are required to control the ShockLine Series VNA. The PC Controller and the VNA are connected over an Ethernet network. The required Ethernet cable, test port adapters, and phase-stable through line with any required adapters are not included in the verification kit.
  • Page 5 4. PC Controller Cable Connections to VNA PC Controller Cable Connections to VNA ME7868A Verification Component Connection The basic connections between the PC Controller, the ME7868A VNA, and the verification components are shown below. See Figure 2 below. Note that the setup for any given verification kit varies slightly with additional adapters.
  • Page 6 4. PC Controller Cable Connections to VNA ME7869A Verification Component Connection The basic connections between the PC Controller, the ME7869A VNA, and the verification components are shown below. See Figure 2 below. Note that the setup for any given verification kit varies slightly with additional adapters.
  • Page 7 4. PC Controller Cable Connections to VNA MS46524B Verification Component Connection The basic connections between the PC Controller, the MS46524B VNA, and the verification components are shown below. See Figure 4 below. Note: For the MS46524B: Port-1/Port-2 are verified as a set and Port-3 and Port-4 are verified as a set.
  • Page 8 4. PC Controller Cable Connections to VNA MS46322B Verification Component Connection The basic connections between the PC Controller, the MS46322B VNA, and the verification components are shown below. See Figure 6 below. 1. ShockLine Series VNA 5. Port 1 Adapter (if needed) 2.
  • Page 9 5. Installing the ShockLine Performance Verification Software (PVS). Installing the ShockLine Performance Verification Software (PVS) This section describes how to install the Performance Verification Software (PVS) application and how to use the PVS user interface functions. Installing the Software The software is contained on the USB Memory Device supplied with each Verification Kit. Refer to Section 2.
  • Page 10 5. Installing the ShockLine Performance Verification Software (PVS). Anritsu ShockLine Verification Program Screen When the PVS Installation is complete, the Verification Software navigation page will then appear. See Figure 1. Menu Bar – File, Utilities, Help 8. Test Result– Test results Display 2.
  • Page 11 5. Installing the ShockLine Performance Verification Software (PVS). Setup the VNA and Verification Performance Software communication The Performance Verification Software program must be set-up to communicate with the VNA. To locate the VNA Network Address, on the VNA select: Main Menu | System | Network Interface. Refer to Figure 10.
  • Page 12 6. Adding Performance Verification Tools Adding Performance Verification Tools This section describes how to enter the required testing tools and components into the PVS program to perform a full performance verification. Adding the PVS Tools The following tools are required to perform a full VNA performance verification: Verification Kit •...
  • Page 13 6. Adding Performance Verification Tools 4. Select the Import Verification Kit Data tab on lower left of the Station Asset Utility menu. • A Import Verification Kit Data screen will appear. See Figure 12 Figure 12. Import Verification Kit Data Screen 5.
  • Page 14 6. Adding Performance Verification Tools • Add components to the Station Asset Utility list that are required for the Performance Verification testing, e.g. TOSLKF50A-40 and TOSLK50A-40. Figure 14. Additional Asset Information 13. Enter the Performance Verification tools adapters etc. into each field. 14.
  • Page 15 7. Starting Performance Verification Testing Starting Performance Verification Testing This section describes the performance verification testing process. 1. From the main Performance Verification Menu screen, select Start Session located at the top center part of the PVS screen. See.Figure 16 1.
  • Page 16 7. Starting Performance Verification Testing Figure 17. Starting New Session (Example) 2. Select OK to start Performance Verification testing. • An Unable to Connect Message will display when there is a discrepancy in the setup. The problem must be resolved before continuing with testing. 3.
  • Page 17 7. Starting Performance Verification Testing Test(s) that appear grayed-out indicate that not all equipment required those tests have been entered in the Station Asset Utility list. See Figure 19. Hover the mouse over the grayed test to Note display the test equipment that is not available. To enter the asset of the missing test equipment, go Section “To Add More Components:”...
  • Page 18 7. Starting Performance Verification Testing Close/Finish/View Data Report You can either close a session and continue later, or finish a session when all testing is complete and then view the testing data results. 1. Close Session – Closes and saves the test session. 2.
  • Page 19 7. Starting Performance Verification Testing Return to the Unfinished Session 1. Select Start Session from the Performance Verification Software main screen. • A dialog box will appear indicating a performance verification session already exists for your model/serial number. Figure 23. Existing Session 2.
  • Page 20 7. Starting Performance Verification Testing • The dialog box will appear as shown below. See Figure Figure 25. View Data/Report From here, select from the list displayed or enter in the Model Number and Serial Number to obtain the data to be displayed.