Download Print this page

GPS -FC24-AC Installation, Operation & Maintenance Manual

2,400 cfm auto-cleaning needlepoint bipolar ionization system

Advertisement

Quick Links

GPS-FC24-AC
2,400 CFM Auto-Cleaning Needlepoint
Bipolar Ionization System
Product Description
The GPS-FC24-AC is an auto-cleaning, needlepoint bipolar ionization system designed to handle up to 2,400 CFM. The
unit is designed for multiple mounting options including fan inlet, interior duct wall or interior duct floor. The composite
and carbon fiber construction allows the product to be mounted in corrosive environments.
Standard Features
Universal voltage input, in-line On/Off switch, programmable auto-cleaning cycle, plasma on indication light,
alarm contacts, magnets for ease of installation and replaceable carbon fiber brush emitters.*
*Life cycle testing shows no mechanical degradation of the carbon fiber brushes due to repeated cleaning cycles
Benefits
Particle Reduction and Smoke Control
Odors Neutralized by destroying VOCs
Pathogens Killed (Bacteria, Viruses, Mold), Helps to Control Allergens/ Asthma*, Prevents Dirty Sock Syndrome
Energy Savings of 30% by Reducing Outdoor Air Intake by up to 75%, reduces pressure loss by keeping coils clean
without expensive UV system, and requires No Maintenance!
*These statements are based on numerous customer testimonials and have not been evaluated by the FDA
Specifications
Input Voltage
Frequency
Total
Ion Output
Airflow Capacity
Temperature/Humidity
Unit Dimensions/Weight
Electrical Listings
Alarm Contact Rating
Compliance & Certifications
Engineering Air for a Cleaner World
24VAC to 240VAC
Amps
0.17-0.017A operating/0.33-0.03A cleaning cycle
Power
4 Watts operating / 8 Watts cleaning cycle
50/60HZ
> 300 Million ions/cc/sec
0 to 2,400 CFM or up to 6 tons
-20°F to 200°F / 0 - 100% RH
7.9"L x 1.1"W x 5.0"H / 1.25 lbs
UL, cUL, CE
250VAC / 1A
UL 867, OSHPD Seismic (OSP), IAQP
GPS, GPS-FC24-AC, Global Plasma Solutions and its logos are trademarks of Global Plasma Solutions, Inc.
TM
www.GlobalPlasmaSolutions.com
Commercial Applications
• Schools and Universities
• Arenas and Stadiums
• Transportation Hubs
• Office Buildings
• Manufacturing
• Food Service
• Animal Care
• Institutional
• Senior Care
• Healthcare
• Hospitality
• Child Care
• Worship
Global Plasma Solutions, Inc.
© 2019 Global Plasma Solutions, Inc.

Advertisement

loading
Need help?

Need help?

Do you have a question about the GPS-FC24-AC and is the answer not in the manual?

Questions and answers

Summary of Contents for GPS GPS-FC24-AC

  • Page 1 Bipolar Ionization System Product Description The GPS-FC24-AC is an auto-cleaning, needlepoint bipolar ionization system designed to handle up to 2,400 CFM. The unit is designed for multiple mounting options including fan inlet, interior duct wall or interior duct floor. The composite and carbon fiber construction allows the product to be mounted in corrosive environments.
  • Page 2 GLOBAL PLASMA SOLUTIONS GPS-FC24-AC Installation Operation & Maintenance Manual 3101 Yorkmont Road Suite 400 Charlotte, NC 28208 (980) 279-5622 www.globalplasmasolutions.com 030120-GPSFC24-IOM REV A.docx...
  • Page 3 5. Install the GPS-FC24-AC so that airflow is passing by both emitters at the same time (like a football through goalposts). Make sure the unit is positioned so it obstructs as little airflow as possible.
  • Page 4 Browns Dry Contacts/BAS Alarm 3. Wire in BAS terminals (optional) The GPS-FC24-AC is equipped with a set of dry contacts that are normally open and close when the GPS-FC24-AC is on and has no faults. The contacts are rated up to 250VAC and 1A.
  • Page 5 © 2019 Global Plasma Solutions, Inc. © 2019 Global Plasma Solutions, Inc. GPS, GPS-DM48-AC, Global Plasma Solutions and its logos are trademarks of Global Plasma Solutions, Inc. ® GPS, GPS-DM48-AC, Global Plasma Solutions and its logos are trademarks of Global Plasma Solutions, Inc.
  • Page 6 GLOBAL PLASMA SOLUTIONS GPS-DM48-AC Installation Operation & Maintenance Manual 3101 Yorkmont Road Suite 400 Charlotte, NC 28208 (980) 279-5622 www.globalplasmasolutions.com 020120-GPSDM48-IOM REV B.docx...
  • Page 7 2. Find an appropriate location. Verify the 8-inch depth clearance for the GPS-DM48-AC. 3. Cut a 4-inch round hole in the duct. 4. Install the GPS-DM48-AC so that airflow is passing by both emitters at the same time (like a football through goalposts). The conduit and connection grommet should be pointed down or to the side.
  • Page 8 CAUTION! NEVER TOUCH BRUSHES WHILE OPERATING - SHOCK MAY OCCUR Once powered, the unit initiates an internal check of all systems. After initializing the display will blink between “ON”, “GPS”, and the number of days the unit has been powered. If there is a fault, “FALT” will be displayed.
  • Page 9 Submittal Sheet 23 3/4" LOUVERED DISCHARGE SLOPED TOP 34 3/4" 31 1/4" ON/OFF SWITCH & FAN ADJUSTMENT 2 1/2" HEPA FILTER LOUVERED INTAKE SIDE ACCESS PRE FILTER PANEL 23 3/4" ELECTRICAL ENCLOSURE CASTER NOMINAL AIRFLOW (CFM) FULL LOAD AMPS SOUND (dBA) UNIT WEIGHT 115V 4.6 A...

This manual is also suitable for:

Gps-dm48-ac