Orvaldi VT1-3K on-line LCD User Manual

Uninterruptible power supply system

Advertisement

Quick Links

User Manual
ORVALDI VT1-3K on-line LCD
Uninterruptible Power Supply System
Version:1.9

Advertisement

loading
Need help?

Need help?

Do you have a question about the VT1-3K on-line LCD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Orvaldi VT1-3K on-line LCD

  • Page 1 User Manual ORVALDI VT1-3K on-line LCD Uninterruptible Power Supply System Version:1.9...
  • Page 2 Table of Contents 1. Important Safety Warning ........................1 1-1. Transportation ............................1 1-2. Preparation ............................1 1-3. Installation ............................1 1-4. Operation ............................. 1 1-5. Maintenance, service and faults......................2 2. Installation and setup ..........................3 2-1. Rear panel view ........................... 3 2-2.
  • Page 3 1. Important Safety Warning Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly and read carefully the following instructions before installing the unit. Do not operate this unit before reading through all safety information and operating instructions carefully 1-1.
  • Page 4 1-5. Maintenance, service and faults The UPS system operates with hazardous voltages. Repairs may be carried out only by  qualified maintenance personnel. Caution - risk of electric shock. Even after the unit is disconnected from the mains  (building wiring outlet), components inside the UPS system are still connected to the battery and electrically live and dangerous.
  • Page 5 2. Installation and setup NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. Please keep the original package in a safe place for future use. 2-1. Rear panel view VT1K India Type IEC Type Schuko Type Universal Type VT2K...
  • Page 6 VT1KL India Type IEC Type Schuko Type Universal Type VT2KL India Type IEC Type Schuko Type Universal Type Argentina Type UK Type India Type IEC Type Schuko Type Universal Type 1. AC input 2. Input circuit breaker 3. USB communication port 4.
  • Page 7 2-2. Operating principle The operating principle of the UPS is shown as below The UPS is composed of mains input, EMI/RFI filters, rectifier/PFC, inverter, battery charger, DC-to-DC converter, battery, dynamic bypass and UPS output. 2-3. Setup the UPS Step 1: Connect battery wires If UPS is long-run model, please connect external batteries as below chart.
  • Page 8 If using rack UPS, the UPS is shipped out from factory without connecting battery wires for safety consideration. Before installing the UPS, please follow below steps to re-connect battery wires first. Step 1 Step 2 Step 3 Remove front panel. Connect the AC input and Put the front panel back to the re-connect battery wires.
  • Page 9 Step 5: Turn on the UPS Press the ON/Mute button on the front panel for two seconds to power on the UPS. Note: The battery charges fully during the first five hours of normal operation. Do not expect full battery run capability during this initial charge period. Step 6: Install software For optimal computer system protection, install UPS monitoring software to fully configure UPS shutdown.
  • Page 10 3-2. LCD Panel Display Function Remaining backup time information Indicates the remaining backup time in pie chart. Indicates the remaining backup time in numbers. H: hours, M: minute, S: second Fault information Indicates that the warning and fault occurs. Indicates the warning and fault codes, and the codes are listed in details in 3-5 section.
  • Page 11 Indicates the ECO mode is enabled. Indicates the Inverter circuit is working. Indicates the output is working. Battery information Indicates the Battery level by 0-25%, 26-50%, 51-75%, and 76-100%. Indicates the battery is fault. Indicates low battery level and low battery voltage. Input &...
  • Page 12 3-5. UPS Setting There are three parameters to set up the UPS. Parameter 1 Parameter 1: It’s for program alternatives. Refer to below table. Parameter 2 and parameter 3 are the setting options or values for each program. Parameter 2 Parameter 3 01: Output voltage setting ...
  • Page 13 Parameter 3: Enable or disable ECO function. You may choose the following two options: ENA: ECO mode enable DIS: ECO mode disable (Default) 05: ECO voltage range setting  Interface Setting Parameter 2 & 3: Set the acceptable high voltage point and low voltage point for ECO mode by pressing Down key or Up key.
  • Page 14 90Vac to 110Vac. (Default: 90Vac) 8: Autonomy limitation setting  Interface Setting Parameter 3: Set up backup time on battery mode for general outlets. 0-999: setting the backup time in minutes from 0-999 for general outlets on battery mode. 0: When setting as “0”, the backup time will be only 10 seconds.
  • Page 15 3-6. Operating Mode Description Operating mode Description LCD display Online mode When the input voltage is within acceptable range, UPS will provide pure and stable AC power to output. The UPS will also charge the battery at online mode. ECO mode Energy saving mode: When the input voltage is within voltage regulation range, UPS will bypass...
  • Page 16 3-7. Faults Reference Code Fault event Fault code Icon Fault event Fault code Icon Bus start fail Inverter output short Bus over Battery voltage too high Bus under Battery voltage too low Bus unbalance Over temperature Inverter soft start failure Overload Inverter voltage high Charger failure...
  • Page 17 4. Troubleshooting If the UPS system does not operate correctly, please solve the problem by using the table below. Symptom Possible cause Remedy No indication and alarm even The AC input power is not Check if input power cord though the mains is normal. connected well.
  • Page 18 Symptom Possible cause Remedy Battery backup time is shorter Batteries are not fully Charge the batteries for at than nominal value charged least 5 hours and then check capacity. If the problem still persists, consult your dealer. Batteries defect Contact your dealer to replace the battery.
  • Page 19 6. Specifications Tower UPS MODEL ORVALDI VT1K ORVALDI VT2K ORVALDI 3K CAPACITY* 1000 VA / 900 W 2000 VA / 1800 W 3000 VA / 2700 W INPUT 90VAC/80VAC/70VAC/60VAC±5% or 180VAC/160VAC/140VAC/120VAC±5% Low Line Transfer (Ambient Temp.<35 ( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0) 100VAC/90VAC/80VAC/70VAC or 195VAC/175VAC/155VAC/135VAC ±...