Carrier AGAGC9PNS01E Installation Instructions Manual

Gas conversion kit, propane to natural condensing (90%+) furnaces

Advertisement

Quick Links

AGAGC9PNS01E
Gas Conversion Kit, Propane to Natural
Condensing (90%+) Furnaces
40,000 BTUh to 140,000 BTUh Models Only
NOTE: Read the entire instruction manual before starting the
installation.
SAFETY CONSIDERATION
WARNING
!
FIRE, EXPLOSION, ELECTRICAL SHOCK, AND
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal injury or death.
This conversion kit shall be installed by a qualified service agency in
accordance with the manufacturer's instructions and all applicable
codes and requirements of the authority having jurisdiction. If the
information in these instructions is not followed exactly, a fire,
explosion, or production of carbon monoxide could result causing
property damage, personal injury, or loss of life. The qualified service
agency is responsible for the proper installation of this furnace with this
kit. The installation is not proper and complete until the operation of the
converted appliance is checked as specified in the manufacturer's
instructions supplied with the kit.
AVERTISSEMENT
!
LE FEU, L'EXPLOSION, CHOC ELECTRIQUE,
ET MONOXYDE DE CARBONE EMPOISONNER
Cette trousse de conversion doit être installée par un servie d'entretien
qualifié, selon les instructions du fabricant et selon toutes les exigences
et tous les codes pertinents de l'autorité compétente. Assurezvous de
bien suivre les instructions dans cette notice pour réduire au minimum
le risque d'incendie, d'explosion ou la production de monoxyde de
carbone pouvant causer des dommages matériels, de blessure ou la
mort. Le service d'entretien qualifié est responsable de l'installation de
cette trousse. L'installation n'est pas adéquate ni complète tant que le
bon fonctionnement de l'appereil converti n'a pas été vérfié selon les
instructions du fabricant fornies avec la trousse.
Installing and servicing heating equipment can be hazardous due to gas
and electrical components. Only trained and qualified personnel should
install, repair, or service heating equipment.
Untrained personnel can perform basic maintenance functions such as
cleaning and replacing air filters. Trained service personnel must
perform all other operations. When working on heating equipment,
Installation Instructions
A200203
observe precautions in the literature, on tags, and on labels attached to or
shipped with the unit, and other safety precautions that may apply.
Follow all safety codes. In the United States, follow all safety codes
including the current edition of the National Fuel Gas Code (NFGC)
NFPA No. 54/ANSI Z223.1. In Canada, refer to the current edition of the
National Standard of Canada, Natural Gas and Propane Installation
Codes (NSCNGPIC), CAN/CSA-B149.1 and .2. Wear safety glasses and
work gloves. Have a fire extinguisher available during start-up,
adjustment steps, and service calls.
Recognize safety information. This is the safety-alert symbol
you see this symbol on the furnace and in instructions or manuals, be
alert to the potential for personal injury. Understand the signal words
DANGER, WARNING, CAUTION and NOTE. The words DANGER,
WARNING, and CAUTION are used with the safety alert symbol.
DANGER identifies the most serious hazards which will result in severe
personal injury or death. WARNING signifies a hazard which could
result in personal injury or death. CAUTION is used to identify unsafe
practices which may result in minor personal injury or product and
property damage. NOTE is used to highlight suggestions which will
result in enhanced installation, reliability, or operation.
INTRODUCTION
WARNING
!
FIRE, EXPLOSION, ELECTRICAL SHOCK AND
CARBON MONOXIDE POISONING HAZARD
Failure to follow instructions could result in personal injury, death or
property damage.
Improper installation, adjustment, alteration, service, maintenance, or
use can cause carbon monoxide poisoning, explosion, fire, electrical
shock, or other conditions, which could result in personal injury or
death. Consult your distributor or branch for information or assistance.
The qualified installer or agency must use only factory-authorized kits
or accessories when servicing this product.
WARNING
!
FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury, death or
property damage.
Gas supply MUST be shut off before disconnecting electrical power
and proceeding with conversion.
. When

Advertisement

loading
Need help?

Need help?

Do you have a question about the AGAGC9PNS01E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Carrier AGAGC9PNS01E

  • Page 1 AGAGC9PNS01E Gas Conversion Kit, Propane to Natural Condensing (90%+) Furnaces 40,000 BTUh to 140,000 BTUh Models Only Installation Instructions NOTE: Read the entire instruction manual before starting the observe precautions in the literature, on tags, and on labels attached to or installation.
  • Page 2 AGAGC9PNS01E: Installation Instructions TWO-STAGE & MODULATING CONDENSING WARNING FURNACES Table 3 – Two-Stage & Modulating Condensing Furnaces ELECTRICAL SHOCK, FIRE OR EXPLOSION HAZARD Failure to follow this warning could result in personal injury, death or Model Numbers Beginning with: property damage.
  • Page 3 AGAGC9PNS01E: Installation Instructions NOTE: Use a back-up wrench on the gas valve to prevent the valve ORIFICE SELECTION/DERATE from rotating on the manifold or damaging the mounting to the burner box. CAUTION 1. Disconnect the gas pipe from gas valve and remove pipe from the furnace casing (Fig.
  • Page 4 AGAGC9PNS01E: Installation Instructions SINGLE-STAGE GAS VALVE TWO-STAGE GAS VALVE *Orifice numbers shown in BOLD are factory installed. A11252A * Orifice numbers shown in BOLD are factory installed. A11253A A11252B Table 5 – Orifice Size and Manifold Pressure (in.w.c.) for Gas Input...
  • Page 5 AGAGC9PNS01E: Installation Instructions MODULATING GAS VALVE MODULATING GAS VALVE (60,000 BTUh ONLY) Table 6 to be used with Modulating Furnaces EXCEPT the 60,000 Table 7 to be used with Modulating Furnaces 60,000 BTUh INPUT IN BTUh INPUT IN 21-IN. WIDE CASING 21-IN.
  • Page 6 AGAGC9PNS01E: Installation Instructions SINGLE-STAGE GAS VALVE A240215 A240216 Fig. 5 – Conversion Kit Rating Plate (40,000 BTUh to 140,000 BTUh ONLY) Single-Stage Furnace TWO-STAGE GAS VALVE A240213 A240214 Fig. 6 – Conversion Kit Rating Plate (40,000 BTUh to 120,000 BTUh ONLY) Two-Stage Furnace...
  • Page 7 AGAGC9PNS01E: Installation Instructions MODULATING GAS VALVE A240211 A240212 Fig. 7 – Conversion Kit Rating Plate (40,000 BTUh to 120,000 BTUh ONLY) Modulating Furnace INSTALL ORIFICES REINSTALL BURNER ASSEMBLY 1. Install main burner orifices. Do not use PTFE thread-seal tape. To reinstall burner assembly: Finger-tighten orifices at least one full turn to prevent 1.
  • Page 8 AGAGC9PNS01E: Installation Instructions Single Stage Gas Valve 1. Refer to Fig. 5. Verify the gas valve has a white label with black lettering on top of the operator. 2. Be sure gas and electrical supplies to furnace are off. 3. Remove caps that conceal adjustment screws for the gas-valve regulators, see Fig.
  • Page 9 AGAGC9PNS01E: Installation Instructions Two Stage Gas Valve Refer to Fig. Fig. 15or Fig. 1. Remove caps that conceal adjustment screws for high heat and low heat gas-valve regulators, see Fig. Fig. 15, or Fig. 2. Remove the high heat and low heat propane regulator adjustment screws.
  • Page 10 AGAGC9PNS01E: Installation Instructions REMOVE LOW GAS PRESSURE SWITCH NOTE: Remove the Low Gas Pressure Switch before installing the manifold on the burner assembly. NOTE: There are two ways that the Low Gas Pressure Switch (LGPS) could have been installed during the original natural to Propane gas conversion.
  • Page 11 AGAGC9PNS01E: Installation Instructions Casings Wider Than 14 3/16-in/Vent Does Not Pass CHECK INLET GAS PRESSURE Between Inducer and Burner Assembly CAUTION If the vent pipe does not pass between the inducer and burner assembly, or the furnace is wider than a 14 3/16-in. wide casing. The switch is...
  • Page 12 AGAGC9PNS01E: Installation Instructions b. Furnace controls with 3 digit display, navigate to (Htt) and select (2st), see Fig. 24 Fig. 25. See furnace installation manual for additional instructions. 2. Jumper R-W/W1 and R-W2 thermostat connections on control. 3. When main burners ignite, confirm inlet gas pressure is between 4.5-in.
  • Page 13 AGAGC9PNS01E: Installation Instructions A221035A Representative drawing only, some models may vary in appearance. Fig. 28 – Example of Two-Stage Speed Furnace Control for VCA or VCT Blower Motor (view 3) Fixed Speed Blower (FCT), Two-Stage Gas Valve A200176 1. Turn Setup Switch SW1 (LHT or TT) on furnace control ON, see Representative drawing only, some models may vary in appearance.
  • Page 14 AGAGC9PNS01E: Installation Instructions Or, on some models, tighten set screw on inlet tower pressure tap AVERTISSEMENT with a 3/32-in. hex wrench, see Fig. RISQUE D’EXPLOSION ET D’INCENDIE Le non-respect des avertissements de sécurité pourrait d’entraîner des blessures graves, la mort ou des dommages matériels.
  • Page 15 AGAGC9PNS01E: Installation Instructions 11. Remove manometer and on some models remove pressure tap b. Furnace controls with 3 digit display, navigate to (Htt) and fitting. select (2st). See furnace installation manual for additional instructions. 12. On some models, apply pipe dope sparingly to end of 1/8-in. (3 mm) pipe plug and install in the manifold pressure tap opening.
  • Page 16 AGAGC9PNS01E: Installation Instructions Modulating Gas Valve b. Furnace controls with 3 digit display, navigate to (Htt) and select (1St) for a single-stage thermostat, (2St-LHt) for a CAUTION two-stage thermostat running low heat, or (2St-iHt) for a two-stage thermostat running intermediate heat. See furnace installation manual for additional instructions.
  • Page 17 Fig. 36 – Gas Control Conversion Label ©2024 Carrier. All Rights Reserved. Edition Date: 05/24 Catalog No: AG-KC019SPN-05 A Proud Member of the Carrier Family Replaces: AG-KC019SPN-04 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.