The upper display shows the time of day, the lower the start number (three digits) and count-
down (seconds only) to the start of the next racer.
5
Interface for Display Board
The baud rate is factory adjusted to 19200 baud in order to receive the data through the inter-
face. This means you can only use D-LINE display boards (no GAZ-type).
Output format:
Bit rate:
Transmission protocol:
Display Board without address (time of day or running time of first starter)
xxx.xxxxHH:MM:SS.x(CR) ................... Running time (with 1/10 seconds)
A ............................ Address (A = Track 1, B = Track 2, C = Track 3, D = Track 4, E = Track 5,
F = Track 6)
NNN ....................... Start number (hundreds, tens, units - digit 1 to 3)
. ............................ a point on the fourth digit is the identification for a running time
HH:MM:SS. ............ time in hours, minutes, seconds
x ............................. blank
(CR)
carriage return
Manual
TIMY2 – StartLiner
1 start-bit, 8 data-bit, no parity-bit, 1 stop-bit
factory setting: 19200 baud (necessary for ALGE GAZ display board)
2400, 4800, 9600, 19200
ASCII
Copyright by:
ALGE-TIMING GmbH
Rotkreuzstr. 39
6890 Lustenau / Austria