Stairville RevueLED 120 COB 3200K DMX User Manual
Stairville RevueLED 120 COB 3200K DMX User Manual

Stairville RevueLED 120 COB 3200K DMX User Manual

Led spotlight

Advertisement

Quick Links

RevueLED 120 COB 3200K DMX
LED Spotlight

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RevueLED 120 COB 3200K DMX and is the answer not in the manual?

Questions and answers

Summary of Contents for Stairville RevueLED 120 COB 3200K DMX

  • Page 1 RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 2 Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 Internet: www.thomann.de 31.10.2024, ID: 393346 (V5)
  • Page 3: Table Of Contents

    Connections and controls........................19 Operating..............................21 7.1 Starting the device........................... 21 7.2 Operation on the device........................ 21 Technical specifications........................24 Plug and connection assignments....................27 Troubleshooting............................28 Cleaning............................... 30 Protecting the environment......................31 RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 4 RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 5: General Information

    1.1 Symbols and signal words In this section you will find an overview of the meaning of symbols and signal words that are used in this document. RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 6 Warning signs Type of danger Warning – high-voltage. Warning – dangerous optical radiation. Warning – suspended load. RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 7 General information Warning signs Type of danger Warning – danger zone. RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 8: Safety Instructions

    Always dispose of packaging material properly when it is not in use. Never allow children to use the device without supervi‐ sion. Keep small parts away from children and make sure that the device does not shed any small parts (such knobs) that children could play with. RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 9 Always secure the barn door with a safety cable on the spotlight. The safety cable must run outside the barn door to not interfere with the light emission. RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 10 (FI). Ensure that the power cord plug is easily accessible at all times if it is the only device to safely disconnect the device from the mains supply. As a precaution, disconnect the device from the power grid when storms are approaching or it the device will not be used for a longer period. RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 11 Using fuses of a different type than compatible with the device may cause a fire and seriously damage the device. Only use fuses of the same type. Observe the labelling on the device casing and the information in the "Technical data” chapter. RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 12: Features

    For technological reasons, the light output of LEDs decreases over their lifetime. This effect increases with higher operating temperature. You can extend the service life of the illuminants by providing adequate ventilation and operating the LEDs with the lowest possible brightness. RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 13: Installation

    Always secure the barn door with a safety cable on the spotlight. The safety cable must run outside the barn door to not interfere with the light emission. RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 14 If the spotlight is operated with the barn doors closed, there is a risk of over‐ heating and fire. In addition, even short-term operation with the barn doors closed can reduce the service life of the LEDs. Operate the device only with open barn doors. RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 15 If the DMX connections are wired incorrectly, this can cause errors during the data transfer. Do not connect the DMX input and output to audio devices, e.g. mixers or ampli‐ fiers. Use special DMX cables for the wiring instead of normal microphone cables. RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 16 The safety cable must be attached to the safety cable eyelet. Please note that this device must not be connected to a dimmer. RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 17: Starting Up

    Connect the output of the first DMX device to the input of the second one, and so on to form a daisy chain. Always ensure that the output of the last DMX device in the daisy chain is terminated with a resistor (110 Ω, ¼ W). RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 18 Connect the DMX output of the master device to the DMX input of the first slave device. Then connect the DMX output of the first slave device to the DMX input of the second slave device and so on. RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 19: Connections And Controls

    Connections and controls Connections and controls & DMX INPUT DMX OUTPUT ö POWER OUT POWER IN F2AL250V [[[[ MENU DOWN ENTER RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 20 [ENTER] | Selects an option of the respective operating mode. 9 [F2AL250V] | Fuse holder 10 [POWER OUT] | Lockable output socket (Power Twist) for the power supply for further devices 11 Safety cable eyelet RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 21: Operating

    When the display shows the required menu or value, press [ENTER]. ð The respective submenu is displayed or the new value is confirmed. To return to the previous menu level without changes, press [MENU]. RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 22 Use [UP] or [DOWN] to specify the flash frequency for the strobe effect in a range from ‘ST00’ … ‘ST99’ (off, fast … slow) and confirm with [ENTER]. To return to the previous menu level without changes, press [MENU]. RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 23 Use [UP] and [DOWN] to enable the required slave mode ( ‘SL0’ … ‘SL3’ ) and confirm with [ENTER]. ð The device is now running in slave mode, i.e. it will copy the behaviour of the con‐ trolling master device exactly if the wiring is correct. RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 24: Technical Specifications

    DOWN ENTER 258 mm 557 mm Light source 1 × COB LED, warm white, 120 W Light source properties Colour temperature 3200 K Colour rendering index CRI 90 Optical properties Beam angle 50° RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 25 IP20 Mounting options Hanging, standing Dimensions (W × H × D) 258 mm × 164 mm × 557 mm Weight 5.5 kg Ambient conditions Temperature range 0 °C…40 °C Relative humidity 20%…80% (non-condensing) RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 26 Technical specifications Further information Floor housing Remote control Not possible Housing colour Black Design Theatre spotlight Optic Reflector Fanless Wireless DMX Rechargeable battery Not possible Suitable for outdoor use RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 27: Plug And Connection Assignments

    The unit offers a 3-pin XLR socket for DMX output and a 3-pin XLR plug for DMX input. Please refer to the drawing and table below for the pin assignment of a suitable XLR plug. Configuration Ground, shielding Signal inverted (DMX–, ‘cold signal’) Signal (DMX+, ‘hot signal’) RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 28: Troubleshooting

    Use special DMX cables for the wiring instead of normal microphone cables. In the following we list a few common problems that may occur during operation. We give you some suggestions for easy troubleshooting: RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 29 DMX mode on another device. If the procedures recommended above do not succeed, please contact our Service Center. You can find the contact information at www.thomann.de. RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 30: Cleaning

    The fan grids of the device must be cleaned of any contamination, such as dust, etc. on a reg‐ ular basis. Before cleaning, switch off the device and disconnect mains-operated devices from the mains. Only use pH-neutral, solvent-free and non-abrasive cleaning agents. Clean the unit with a slightly damp lint-free cloth. RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 31: Protecting The Environment

    Do not dispose of these materials with your normal household waste, but make sure that they are collected for recycling. Please follow the instructions and markings on the packaging. Observe the disposal note regarding documentation in France. RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 32 Also note that waste avoidance is a valuable contribution to environmental protection. Repairing a device or passing it on to another user is an ecologically valuable alternative to disposal. If your old device contains personal data, delete those data before disposing of it. RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 33 Notes RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 34 Notes RevueLED 120 COB 3200K DMX LED Spotlight...
  • Page 36 Musikhaus Thomann · Hans-Thomann-Straße 1 · 96138 Burgebrach · Germany · www.thomann.de...

This manual is also suitable for:

393346

Table of Contents