Endress+Hauser levelflex M FMP 41 C Operating Instructions Manual page 2

Hart/4...20 ma guided level-radar
Hide thumbs Also See for levelflex M FMP 41 C:

Advertisement

KA 189F/00/a2/03.02
52012501
000
measured value
-
+
E
Group
selection
00
002
basic setup
tank
properties
+
01
- standard
safety settings
- aluminium tank
- plastic tank
- bypass/pipe
- coax-probe
- concrete
wall
03
030
length
end of
adjustment
probe
- free
04
- tie down
linearisation
isolated
05
- tie down
extended calibr.
gnd.
092
09
language
display
0E
envelope curve
- envel. curve
- substracted signal
- mapping
-
0A0
0A
present
diagnostics
error
0C
system
parameters
!
2
Brief operating instructions
Levelflex M - Brief operating instructions
Contrast:
+
or
-
+
003
004
process
medium
property
cond.
- unknown
- standard
- 1.4 ... 1.6
- fast
- 1.6 ... 1.9
change
- 1.9 ... 2.5
- slow
- 2.5 ... 4
change
- 4 ... 7
- test: no filter
- > 7
031
032
probe
probe
length
please enter probe length here.
... ...
09A
09B
recording
plot settings
curve
- single curve
- cyclic
0A1
0A3
previous
reset
error
(333 = reset customer parameters)
Note!
This operating manual explains the installation and initial start-up for the level transmitter
measuring device. All functions that are required for a typical measuring task are taken
into account here.
In addition, the Levelflex M provides many other functions that are not included in this
operating manual, such as optimising the measuring point and converting the
measured values.
An overview of all device functions can be found on Page 80.
An extensive description of all device functions can be found in BA245F –
"Description of the instrument functions" on the enclosed CD-ROM.
Levelflex M FMP 41 C with HART/4...20 mA
+
E
005
006
008
empty
full
dist./
calibr.
calibr.
meas value
input E
input F
D and L are
(see sketch)
(see sketch) displayed
033
034
probe
determine
length
length
If shortened
threaded
connection
¾ or
1 ½
BSP
(G
¾ or G ½)
1
¾ or 1½ NPT
:
reference point of
measurement
min.level
0A4
unlock
... ...
parameter
= 100: unlocked
100: locked
008
E
dist./
meas value
E
051
052
053
check
start
range of
distance
mapping
mapping
confirm
suggestion
or specify
range
reference point of
measurement
UB
LB
UB = upper blocking distance
L
B = lower bllocking distance
LN = probe lenght
52012501
Endress + Hauser
E
LN
F
L00-FMP40xxx-19-00-00-en-012