Translation of the original instructions IBS-Parts Cleaning Device Type M, MD, M-500 All devices have been tested and certified. IBS Scherer GmbH Tel.: +49 (0) 6701-93 83 -0 Gewerbegebiet Fax: +49 (0) 6701-93 83 -33 Visit our website: D-55599 Gau-Bickelheim E-Mail: info@ibs-scherer.de...
Operating the machine ..........6 6.1. Controls 6.2. Assembly and adjustment 6.2.1. Assembling the Parts Cleaning Device M and MD (M-500 see attachement) 6.2.2. Assembling the IBS-Special Pump 6.2.3. Operation 6.2.4 Changing the drum...
When using cleaning agents from third-party manufacturers, always read and follow the product information and the EC Sa- fety Data Sheet. Their use must be approved by IBS Scherer GmbH. Please also note the information given in section 2.3. The 3-year extended warranty only applies when IBS-Special Cleaning Agents are used.
IBS-Special Cleaning Agent. ∙ Old goods will be collected by IBS Scherer and recycled as long as the mixing ban has been adhered to. 3.2. Safety information ∙...
The device must be installed in a stable, horizontal position on a solvent-resistant floor. 5.2. Space required The device may be placed against a wall. There should be a clear area of approx. 2 m in front of the device. 5.3. Acceptable ambient conditions The device will work optimally at temperatures between -15°C and +40°C.
IBS-Parts Cleaning Devices conform to type class A 1 (EN 12921-3; 3.15.1). A danger area which is appropriate for the operating conditions (e.g. geometry and surface area of workpieces, intensity of cleaning) must be defined. For normal cleaning processes, IBS recommends a danger area of 2 m around the device. DANGER! The danger area identified by means of a risk assessment: ∙...
Pump not working No power Check that mains plug is plugged in Pump is faulty Replace pump Check liquid level, if necessary ask IBS Scherer to change Pump not working Liquid level in drum is too low the drum Pump is faulty Replace pump If the steps described above do not resolve the problem please call 0049-67 01-93 83 -0 or contact us per e-mail at info@ibs-scherer.com.
7.2. Inspection (German DGUV information 209-088 — section 5 / previously German BGR 180) The IBS-Parts Cleaning Device must be inspected for safe working condition by qualified staff, at least once a year and additionally when required. 8. SPARE PARTS AND ACCESSORIES LIST ANNEX EC Declaration of Conformity Type M, MD, M-500 IBS-BA_Typ_M_MD_M500-DE_CZ_PL_ES_EN_03.2020...
IBS-Parts Cleaning Device Type M-500 / Enhanced bearing capacity 500 kg Addition to 6.2.1. Assembling the Parts Cleaning Device ∙ We advise a two-man assembly to avoid damaging during the assembly of the IBS-Parts Cleaning Device Type M-500. ∙ Remove the packaging.
DGUV-Information Cleaning work pieces with liquid cleaning agents (Point 3.1.4. as well as Point 5) 209-088 Authorized for collecting all technical documentation: Mr Torsten Bodtländer, IBS Scherer GmbH, Gewerbegebiet, 55599 Gau-Bickelheim 12.02.2020 Date Axel Scherer, MSc. (General Manager) If the above-named equipment is modified without our consent, this declaration is no longer valid.
Page 13
IBS Scherer GmbH Betriebsanleitung Typ M, MD, M-500 2018...