Page 1
Original operating instructions IBS Parts Cleaning Device Type G-50-W Type G-50-I All devices have been tested and certified. Visit our website: www.ibs-scherer.com...
When using solvents from third-party manufacturers, always read and follow the product information and the EC Safety Data Sheet. Their use must be approved by IBS Scherer GmbH. Please also note the information given in section 2.3. The 3-year extended warranty only applies when IBS Special Cleaning Agents are used.
2.3. Non-approved cleaning agents Halogenated solvents Flammable and highly flammable solvents with flash point < 55°C, except for cleaning agents with flash point > 40°C when technical ventilation (exhaust system) is installed 2.4. Standards Always comply with EN 12921-1 and EN 12921-3. 3.
Contaminated parts (e.g. hoses, cleaning brushes, cleaning cloths, etc.) should be disposed of in accordance with the applicable environmental regulations. Please contact IBS Scherer GmbH if you have any questions.
If you use solvents from other manufacturers, it is essential to read and follow the information and safety instructions provided by the manufacturer. 5.7. Precautionary measures to be taken by the operator IBS Parts Cleaning Devices conform to type class A 1 (EN 12921-3; 3.15.1). A danger area which is appropriate for the operating conditions (e.g.
6. Operating the machine ___________________________________________________ 6.1. Controls The device is switched on with a foot-operated safety switch. 6.2. Assembly and adjustment 6.2.1. Assembling the Parts Cleaning Device Remove the packaging. The device is fully assembled. Remove the protective film from the support rack and place the rack in the cleaning tray. Auflagerost Support tray Ablaufschlauch...
Liquid level in drum is too Check liquid level, if necessary Pump not pumping ask IBS Scherer to change the drum Pump is faulty Replace pump If the steps described above do not resolve the problem, please contact IBS Scherer GmbH.
7. Maintenance / cleaning __________________________________________________ 7.1. Maintenance / cleaning work The mains plug must be removed before carrying out any maintenance or cleaning work. 8. Spare parts list ___________________________________________________________ Spare parts list for IBS Parts Cleaning Devices: Item no. Description Device type BK 50 F2/F2-D...
9. Accessories list _________________________________________________________ Accessories list for IBS Parts Cleaning Devices: Item no. Description Device type BK 50 F2/F2-D G-50-W/I 2120022 IBS collecting tray, type WM/St 2120023 IBS collecting tray, type WK/St 2120024 IBS collecting tray, type WK-50 ...
Page 11
Bickelheim 07.07.2014 ___________________________________ Date Axel Scherer, MSc. (General Manager) If the above named equipment is modified without our consent, this declaration is no longer valid. IBS Scherer GmbH Tel.: +49-6701-9383-0 General Manager: Gewerbegebiet Fax +49-6701-9383-33 Axel Scherer, Dipl.-Ing. 55599 Gau-Bickelheim Mail: info@ibs-scherer.de...
Page 12
Bickelheim 07.07.2014 ___________________________________ Date Axel Scherer, MSc. (General Manager) If the above named equipment is modified without our consent, this declaration is no longer valid. IBS Scherer GmbH Tel.: +49-6701-9383-0 General Manager: Gewerbegebiet Fax +49-6701-9383-33 Axel Scherer, Dipl.-Ing. 55599 Gau-Bickelheim Mail: info@ibs-scherer.de...