ENVIRONMENT CONCERNS ................35 WE’RE THINKING OF YOU Thank you for purchasing an Electrolux appliance. You’ve chosen a product that brings with it decades of professional experience and innovation. Ingenious and stylish, it has been you’ll get great results every time.
ENGLISH SAFETY INFORMATION user manual user manual Before the installation and use of the appliance, carefully read the supplied instructions. The manufacturer is not responsible for any injuries or damage that are the result of incorrect installation or usage. Always keep the instructions in a safe and accessible location for future reference.
Page 4
4 www.electrolux.com • Unplug the appliance before moving or carrying out any maintenance. • If the supply cord is damaged, it must be replaced by persons in order to avoid a hazard. • The appliance shall be installed in accordance with local wiring regulations.
Page 5
ENGLISH • Do not pierce or burn. • Refrigerant gases can be odourless. • This appliance contains a certain number of grams (see rating label back of unit) of R290 refrigerant gas. • R290 is a refrigerant gas that complies with the European directives on the environment.
Page 6
6 www.electrolux.com c) An area exposed to direct sunlight. d) An area where water is likely to splash. e) Near a bath, a shower or a swimming pool. • Never insert your fingers, rods into the air outlet. Take special care to warn children of these dangers.
Page 7
ENGLISH • Contact authorized service technician for repair or maintenance of this unit. • Do not pull , deform . or modify the power supply cord , or immerse it in water . Pulling or misuse of the power supply cord can result in damage to the unit and cause electrical shock.
Page 8
8 www.electrolux.com damaged, please turn off the air switch and disconnect the power supply. It must be replaced from the dealer or a designated repair shop. General instructions for repairing appliances containing R290. • Checks to the area. Prior to beginning work on systems containing flammable refrigerants, safety checks are...
Page 9
ENGLISH relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including igarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which...
Page 10
10 www.electrolux.com inherently resistant to being corroded or are suitably protected against being so corroded. • Checks to electrical devices. Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with.
Page 11
ENGLISH Note: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them. Repair to intrinsically safe components Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use.
Page 12
12 www.electrolux.com calibrated to the refrigerant employed and the appropriate percentage of gas (25 % maximum) is confirmed. Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work.
ENGLISH Charging procedures In addition to conventional charging procedures,the following requirements shall be followed. • Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them.
Page 14
14 www.electrolux.com equipment and cylinders conform to the appropriate standards. • Pump down refrigerant system,if possible. • If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system. • Make sure that cylinder is situated on the scales before recovery takes place.
Page 15
ENGLISH appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge are available.All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant).
Page 16
16 www.electrolux.com training is carried out by national training organisations that are accredited to teach the relevant national competency standards that may be set in legislation. The achieved competence should be documented by a certificate. • Training: The training should include the substance of the following: Information about the explosion potential of flammable...
Page 17
ENGLISH charge or that the ventilation duct is assembled in a correct manner. - Connect the pipes and carry out a leak test before charging with refrigerant. - Check safety equipment before putting into service. b) Maintenance - Portable equipment shall be repaired outside or in a workshop specially equipped for servicing units with flammable refrigerants.
Page 18
18 www.electrolux.com 4.Evacuate again. 5.Remove parts to be replaced by cutting, not by flame. 6.Purge the braze point with nitrogen during the brazing procedure. 7.Carry out a leak test before charging with refrigerant. Reassemble sealed enclosures accurately. If seals are worn, replace them.
Page 19
ENGLISH - Purge the refrigerant circuit with nitrogen for 5 min. - Evacuate again. - Cut out the compressor and drain the oil. Transportation, marking and storage for units that employ ammable refrigerants • Transport of equipment containing flammable refrigerants: Attention is drawn to the fact that additional transportation regulations may exist with respect to equipment containing flammable gas.
Page 20
EDH14TRBD2 "The software in this product contains components that are based on free and open source software. Electrolux gratefully acknowledges the contributions of the open software and robotics communities to the development project. To access the source code of these free and open source software components whose license conditions require publishing, and to see their full copyright information and applicable license terms, please visit: http://electrolux.opensoftwarerepository.com (folder NIU5)"...
ENGLISH 2. PRODUCT DESCRIPTION 2.1 General overview Control panel Castors Louvre / Air outlet Air Quality Index (AQI) indicator Water tank Filter lid / Air intake Water level indication Wire Tag Air quality sensor Power cord Drainage plug / Water outlet Drainage hose 2.2 Control panel layout 12L (Without Connectivity)
Page 22
22 www.electrolux.com Number Symbol Buttons Description To power ON and OFF the appliance. ON/OFF button To activate the appliance hotspot for Connectivity by long press. Connectivity on select models only. To switch between the function settings: • Dryer Function button •...
ENGLISH 3. BEFORE FIRST USE 3.1 Selecting a Location at home with internet connection (Wi-Fi) and an Android or iOS smart phone. Important NOTE: 1. Appliance must be upright for one hour Connect your unit to the 2,4 GHz band prior to operating.
24 www.electrolux.com 4. OPERATING INSTRUCTIONS 4.1 To Turn On the appliance 4.3 Basic function selection Tap " " button to chose your desired make sure the appliance is plugged in basic function between COMPLETE correctly. function, DRYER function and PURIFIER Once plugged, the appliance is on standby function.
ENGLISH 2. When choosing PURIFIER function + SMART mode - the appliance aims to maintain the best indoor air quality (it does not dehumidify). The appliance will automatically adjust fan speed based on input from the PM sensor. Display NOTE: screen on control panel is turned off.
Page 26
26 www.electrolux.com 4.6 Swing The air outlet in the appliance has an in-built louvre. You can turn on this feature, for the louvre to automatically move up & down continuously so as to better direct 2. PURIFIER function + SLEEP mode will have lower noise than COMPLETE + 1.
Page 27
ENGLISH 4.9 Child Lock Indicator the time remaining, until appliance switches ON by itself. Long press " " and " " buttons simultaneously for 5 seconds to activate/ inactivate the Child Lock feature. When the Child Lock feature is activated, the " "...
28 www.electrolux.com 4.12 Filter Change Indicator " will light up to the Electrolux Life App or the Electrolux website on where to purchase plastic protective packaging is removed NOTE: • The high efficiency particle filter cannot be washed, it can only be replaced.
ENGLISH 2. Hold both sides of the water tank with E3- PM2.5 sensor failure even strength, and pull it out from the E4- DC Motor failure unit. E5- Humidity sensor failure E6- Communication Failure E7- Indoor defrost thermistor failure. E8- Refrigerant Leakage NOTE: •...
30 www.electrolux.com NOTE: • When you remove the water tank, do not touch any parts inside the unit, otherwise the product may be damaged. • Be sure to push the water tank gently all the way into the unit. Banging the water...
Vacuum at least once every 4 shock, insulation failure, or rusting. weeks or as per instructions in the • The air intake grille and outlet get Electrolux Life App. soiled easily, so cleaning such parts with a vacuum cleaner is recommended.
Page 32
NOTE: NOTE: DO NOT PUT THE FILTER IN • A DISHWASHER. washed, it can only be replaced. back of the lid. Please visit electrolux.com to order your electrolux.com (Front) (Back) (Front) (Back) Care Ultimate Protect Filter FRESH Active Carbon Filter...
ENGLISH 6. WHAT TO DO IF... Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance. Occurrence Possible Cause Solution Wall plug disconnected.
Page 34
34 www.electrolux.com Occurrence Possible Cause Solution Select Complete function, and adjust Humidity setting is in manual mode to a lower setting or too high. choose Continunous operation for maximum dryness. The higher the moisture in the room air, been installed or the longer it takes for the room air to restarted recently.
ENGLISH Occurrence Possible Cause Solution Check that the router is ON and if other The wireless (Wi- connected devices are working. If the Fi) router is not router was OFF, turn it ON and wait for a working. few minutes and check again. Try to restart the router by unplugging The router needs a The appliance is...
Need help?
Do you have a question about the EDH12TRBD2 and is the answer not in the manual?
Questions and answers