ThermoPro TP-30 - Digital Laser Infrared Thermometer Manual

Package Contents

1x ThermoPro TP30 Infrared Thermometer
2x AAA batteries
1x User Manual

Features & Specifications

  • Laser guided targeting for better aiming precision
  • Narrow distance-spot ratio for accurate results at long distances
  • Safely measure hazardous or inaccessible objects
  • Battery: 2*AAA batteries, 3.0V
  • Measurement Range: -58ºF~1022ºF (-50ºC~550ºC)
  • Accuracy: ±1.5%
  • Resolution: 0.1ºF or 0.1ºC
  • Wavelength: 5um-14um
  • Distance-Spot Ratio: 12:1
  • Response Time: 500ms
  • Emissivity: 0.10-1.00 (Default 0.95)
  • Backlight: Auto-off after 15 seconds
  • Auto-off: Auto-off after 90 seconds of inactivity
  • Low battery Indicator

Function Diagram

Function Diagram

  1. SCAN: When pressing the measurement trigger, SCAN will appear on the display.
  2. HOLD: When the measurement trigger is released, HOLD will appear on the display.
  3. Laser Pointer Indication: When pressing the measurement trigger, a laser beam will appear to help guide you unless the laser is turned off.
  4. Low battery Indication: Will appear on the display when battery power is low.
  5. UPPER DISPLAY: Displays the latest temperature measurement.
  6. EMISS: Press and hold the MODE button for 3 seconds, EMISS will appear, and you can adjust the emissivity setting.
  7. LOWER DISPLAY: Displays MAXIMIN/ AVG temperature; When adjusting the Emissivity setting, the current emissivity setting will be displayed.
  8. MAXIMIN: Maximum and minimum temperature for the latest measurement.
  9. AVG: Average temperature for the latest measurement.

  10. Press once to turn on/off Laser Pointer; Press and hold for 3 seconds, to switch between oc and OF;
    When adjusting the emissivity, press to lower the emissivity.
  11. MODE: Press to cycle through and display MAX/MIN/AVG temperature;
    Press and hold for 3 seconds, to adjust the emissivity setting.

  12. Press to turn on/off the backlight; When adjusting the emissivity, press to increase the emissivity.
  13. Laser Hole
  14. IR Sensor
  15. Measurement Trigger: Hold and release to take temperature readings.
  16. Battery Compartment

Operation

Surface Temperature Measurement

warning NOTE: The ThermoPro TP30 cannot measure the temperature of objects behind glass. Inaccuracy may also occur when exposed to steam, dust or any other contaminants in the air.

  1. Place the included AAA batteries into the Battery Compartment, then press the Measurement Trigger to activate the thermometer.
    Operation - Step 1
  1. Point the T P30 thermometer towards the surface you wish to measure.
  2. Press and hold the Measurement Trigger and the laser will activate for aiming guidance. (Laser will only appear if enabled. Laser is turned on by default.)
  3. Keep holding the Measurement Trigger as you move the TP30 if you wish to continually take a measurement of the surface.
  4. Once the laser is pointed to the desired point of measurement, release the Measurement Trigger and the Upper Display will show the last measured temperature.
  5. Press the Measurement Trigger once again to make another measurement.
    Operation - Step 2

Emissivity

The emissivity of a material is its efficiency in emitting thermal energy.
Non-reflective surfaces have a higher emissivity (closer to 1) than reflective surfaces (closer to 0). Inaccurate results may occur when measuring reflective surfaces such as glass, polished wood, and granite.

To take accurate temperature measurement of reflective surfaces with low emissivity, place a strip of masking tape over the surface and allow for it to adjust to the temperature of the surface for approximately 30 minutes.
Measure the surface, scanning the taped section, eliminating the issue of inaccuracy.

The default emissivity of this device is 0.95, which is suitable for surface temperature measurement of most organic materials and painted objects.
If you would like to improve the measurement accuracy of different objects, you can refer to the emissivity table below.

Aluminum 0.30 Iron 0.70
Asbestos 0.95 Lead 0.50
Asphalt 0.95 Limestone 0.98
Basalt 0.70 Oil 0.94
Brass 0.50 Paint 0.93
Brick 0.90 Paper 0.95
Carbon 0.85 Plastic 0.95
Ceramics 0.95 Rubber 0.95
Concrete 0.95 Sand 0.90
Copper 0.95 Skin 0.98
Sludge 0.94 Snow 0.90
Frozen food 0.90 Steel 0.80
Hot food 0.93 Fabric 0.94
Glass 0.85 Water 0.93
Ice 0.98 Wood 0.94

Distance-Spot Ratio

The ThermoPro TP30 measures surface temperature based on the distance to spot diameter ratio (D: S).As the distance between the thermometer and the surface increases, the total surface area measured will also increase. With a distance to spot ratio of 12:1, the surface area measured has a diameter of roughly1/12 the distance.

For the most accurate results, make sure the target has a surface area of twice the corresponding spot diameter. Insufficient surface area will result in inaccurate results. The recommended distance to hold the thermometer from the surface of measurement is 7.87inch (20cm) away from the surface. This creates a spot measurement area of 0.66inch(1.67cm) in diameter.
Distance-Spot Ratio

Replacing Batteries

Low Battery Indication will appear on the Upper Display when the thermometer's batteries are running low. Immediately replace the batteries when the icon appears.

  1. Open the Battery Compartment and remove the used batteries. Dispose of the used batteries properly.
  2. Insert two new AAA batteries with the correct polarity.
  3. Close the Battery Compartment.

Customer service

Telephone:
1-877-51 5-7797(USA& Canada only)
44-203-769-1321 (UK)

Email: service@buythermopro.com

Hours:
Weekdays 8:00 AM- 8:00 PM EST (USA & Canada only)
Weekdays 1:00PM- 12:00PM CET (UK)

Safe Use & Care

  • DO NOT point the laser beam at another person or animal.
  • DO NOT attempt to point laser beam at an aircraft.
  • Avoid direct/indirect eye contact with the laser-beam. Laser radiation may cause eye damage.
  • DO NOT view the beam with optical instruments.
  • If using near bystanders, make them aware of the dangers of looking directly into the laser beam.
  • DO NOT allow children to operate the device.
  • Use two 1.5V AAA batteries when replacing the batteries within the device.
  • Make sure to insert the batteries in accordance with the correct polarities.
  • ALWAYS remove the batteries when cleaning the device.
  • DO NOT use leaking batteries or dispose of old batteries in fire.
  • Remove the batteries if storing the device for a prolonged period of time.
  • DO NOT disassemble the device or tamper with internal components. Doing so will void any warranty.
  • DO NOT touch the lens or wipe it using anything other than a soft cloth or cotton swab. Keep the thermometer away from electromagnetic fields produced by objects such as arc welders and induction heaters.
  • DO NOT expose the thermometer to direct sources of heat for extended periods of time.
  • The thermometer measures surface temperature, not internal temperature. Do not use it as a reliable source to measure body temperatures.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download ThermoPro TP-30 - Digital Laser Infrared Thermometer Manual

Advertisement

Need help?

Need help?

Do you have a question about the TP-30 and is the answer not in the manual?

Questions and answers

Table of Contents