Dr. Trust 106 Quick Start Manual

A-one galaxy with mdd blood pressure monitor

Advertisement

Quick Links

ABOUT US
Driven by the passion for innovation, we at Dr Trust endeavour to provide our
customers with the latest medical inventions with an objective to promote good
health and wellness all around the world. All the medical devices and health
monitors provided by Dr Trust are supported by accurate, latest and ground
breaking technologies, innovated at our headquarter in NY, USA. All our
products adhere to the most stringent CE and FDA guidelines and are strongly
recommended by doctors and health practitioners. Our products are designed
in the utmost exemplary ways to ensure that their accuracy and convenience
are unrivalled. The ease of their use and operation makes them even more
suitable for users of all age groups.
Dr Trust strives to enhance the quality of lifestyle by providing with the most
trusted and innovative health care and wellness products. Being a renowned
global leader in health care products, Dr Trust ensures that our technically
efficient team works dynamically and tirelessly to provide the best of the
medical devices to our clients. The products that we have to offer are suitably
designed for use at homes, laboratories and hospitals.
Our ground breaking solutions allow you to monitor your health in the easiest
ways possible. In today's era when all of our lives are too hassled to handle, it
becomes a bit difficult to pay attention to our health. But it has now become
easier with the coming of the monitoring devices which can be conveniently
used at homes and even on the go.
We bring to you a variety of best self medical devices, trusted and used by
Doctors, medical professionals and home users all over the world.
10
28
Dr Trust 
A-One Galaxy with MDD Blood Pressure Monitor -106
QUICK START GUIDE
Step 1
Check batteries and insert the air tube
from the cuff into the air jack.
Step 3
Slide the blood pressure cuff onto your
upper arm and secure it so that it sits
snugly about one inch above of your
elbow.
Step 5
The device is intended for giving result
with Cuff deflation, look at the screen
to get your blood pressure reading.
Step 7
Users can make settings for features
like memory and others to make blood
pressure monitoring convenient.
10
Step 2
Before starting the measurement,
make settings for user no., time, and
date etc
Step 4
Simply push the ON/OFF button and
cuff begins to inflate with controlling
deflation speed automatically.
Step 6
Hypertension Classification Indicator
displays coloured results according to
the range between which blood
pressure values lie.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 106 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dr. Trust 106

  • Page 1 ABOUT US Dr Trust  A-One Galaxy with MDD Blood Pressure Monitor -106 Driven by the passion for innovation, we at Dr Trust endeavour to provide our customers with the latest medical inventions with an objective to promote good QUICK START GUIDE health and wellness all around the world.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. INTRODUCTION 6. APPEARANCE OF THE PULSE ARRHYTHMIA INDICATOR 1.1. Features of Dr Trust A one Galaxy FOR EARLY DETECTION 1.2. Important information about self-measurement 7. ERROR MESSAGES /MALFUNCTIONS 2. IMPORTANT INFORMATION ON THE SUBJECT OF 8. CARE AND MAINTENANCE, RECALIBRATION BLOOD-PRESSURE AND ITS MEASUREMENT 2.1.
  • Page 3: Introduction

    1. INTRODUCTION Dr Trust A-One Galaxy Blood Pressure Monitor with MDD -106 is a fully automatic, Too frequent measurements can cause injury to the patient due to blood flow · digital blood-pressure measuring device designed for use on the arm. It uses interference.
  • Page 4: Important Information On The Subject Of Blood-Pressure And Its Measurement

    2. IMPORTANT INFORMATION ON THE SUBJECT OF BLOOD-PRESSURE AND ITS MEASUREMENT between 85 between 30 high to normal Consult your doctor and 90 and 140 2.1. How Does High/Low Blood-Pressure Arise? slight Between90 The level of blood-pressure is determined in a part of the brain, the circulatory between 140 Seek medical advice hypertension...
  • Page 5: Putting The Blood-Pressure Monitor Into Operation

    4. PUTTING THE BLOOD-PRESSURE MONITOR INTO OPERATION Setting the Time, & Date: 4.1 Inserting The Batteries This blood-pressure monitor incorporates an integrated clock with date display. This holds the advantage at each measurement procedure. Along with storing the Insert the batteries (4 x size AA 1.5V), thereby observing the indicated polarity. ·...
  • Page 6: Carrying Out A Measurement

    5. CARRYING OUT A MEASUREMENT 5.1. Before The Measurement 5.3. Fitting The Cuff Avoid eating or smoking directly before the measurement. Refrain from Insert air connector into air outlet as shown in left · exerting yourself before you take the measurement. If you can, take out time to picture and please make sure the air connector is relax by sitting in an armchair in a quite atmosphere for about ten minutes fitted properly to avoid air leakage.
  • Page 7: Measuring Procedure

    5.4. Measuring Procedure 5.6.Memory – Storage and Recall of the Measurements The blood-pressure monitor automatically stores last 120 measurement values for After the cuff has been appropriately positioned, the measurement can begin: each user. By pressing the MEMORY button - an average value of the last 3 measurements as well as the the further last 120 measurements (Mr119, Mr118,…, a) Press the ON/OFF button, the pump begins to inflate the cuff.
  • Page 8: Appearance Of The Pulse Arrhythmia Indicator For Early Detection

    6. APPEARANCE OF THE PULSE ARRHYTHMIA INDICATOR FOR EARLY DETECTION ERR 5 The measured readings indicated an unacceptable difference This symbol indicates detection of pulse irregularities during the measurement. In between systolic and diastolic pressures. Take other reading this case, the result may deviate from your normal blood pressure. In most cases, following directions carefully.
  • Page 9: Care And Maintenance, Recalibration

    9. SAFETY, CARE AND DISPOSAL Safety and Protection Every measurement 1. Repeat the measurement. produces a different value This instrument may be used only for the purpose described in this booklet. The · although the instrument 2. Blood pressure fluctuates continually so manufacturer cannot be held responsible for the damage caused by incorrect functions normally and the successive measurements will show some...
  • Page 10: Reference To Standards

    10. REFERENCE TO STANDARDS Pressure: 30 to 280 mmHg (in 1 mmHg Device Standard: Device corresponds to the requirements of the European Measuring range increment) standard for Pulse: 40 to 199 beat/minute Standard ( for arm BPM with adapter ) Static accuracy Pressure: ±3mmHg / Pulse: ±5% of reading IEC60601-1-6:2010+A1:2013/ EN60601-1-6:2010+A1:2015...
  • Page 11: Manufacturer's Declaration

    Electromagnetic Emissions: (IEC60601-1-2) Weight 510 g±5g (including batteries and cuff) Emission Test Compliance Electromagnetic Environment Cuff pressure display range 0~290mmHg/0~38.7kPa Dr Trust A one Galaxy with MDD uses RF RF emission Group 1 energy only for internal functions. Therefore, CISPR 11 Electrical shock protection: this RF emission is extremely weak and there is little chance of it creating any kind...
  • Page 12 IEC60601-1-2 Electromagnetic Electric fast ±2 kV for power Not applicable Mains power quality Immunity test IEC60601-1-2 test level environment - guidance transient/ burst supply lines should be that of a test level IEC 61000-4-4 ±1 kV for typical commercial or input/output hospital environment.
  • Page 13 Note1: At 80 MHz and 800 MHz, the higher frequency range applies. Dr Trust A one Galaxy with MDD is intended for use in an electromagnetic Note2: These guidelines may not apply in all situations. Electromagnetic environment in which radiated RF disturbances are controlled. The customer or propagation is affected by absorption and reflection from structures, the user of Dr Trust A one Galaxy with MDD can help prevent electromagnetic objects, and people.
  • Page 14: Contact Us

    India: +91-7527013265 /+91-9356658436 Website: www.drtrust.in Corp Website: www.nureca.com Customer Care Executive Email: customercare@nureca.com Connect with us on social networks Facebook: @drtrust Instagram: @drtrustisin Youtube: NurecaUsa © COPYRIGHT 2021 NURECA LTD ALL RIGHTS RESERVED Scan to View Product Demo Video www.drtrustusa.com/106...